Certificate holders

Subtype

Mono Series 12 14 16kW

Certificate Holder
Wamsler Bioenergy GmbH
Adalperostrasse 86
85737 Ismaning
Germany
Registration number
041-K075-06
Certification Body
BRE Global Limited
Subtype title
Mono Series 12 14 16kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,800 kg

Certification Date
16.11.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 12
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

HPM3P12KWEWA
Configure model
Model name
HPM3P12KWEWA
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.2 kW

12 kW

El input

2.49 kW

4 kW

COP

4.9

3

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

70 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

262.5 %

179 %

Prated

12.1 kW

12 kW

SCOP

6.64

4.55

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.1 kW

12 kW

COP Tj = +2°C

3.53

2.39

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

7.78 kW

7.73 kW

COP Tj = +7°C

5.82

3.86

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

3.64 kW

3.59 kW

COP Tj = 12°C

8.31

5.88

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

7.78 kW

7.73 kW

COP Tj = Tbiv

5.82

3.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.53

2.39

WTOL

65 °C

65 °C

Poff

6 W

6 W

PTO

18 W

18 W

PSB

6 W

6 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2435 kWh

3523 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

70 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

168.8 %

126 %

Prated

12.5 kW

11.3 kW

SCOP

4.3

3.23

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

8.08 kW

7.09 kW

COP Tj = -7°C

3.64

2.75

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

4.93 kW

4.44 kW

COP Tj = +2°C

5.34

3.88

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

3.17 kW

3 kW

COP Tj = +7°C

5.28

4.88

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

3.69 kW

3.6 kW

COP Tj = 12°C

9.34

6.61

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

10.17 kW

9.21 kW

COP Tj = Tbiv

2.66

1.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.72 kW

7 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.38

WTOL

65 °C

65 °C

Poff

6 W

6 W

PTO

18 W

18 W

PSB

6 W

6 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.78 kW

4.3 kW

Annual energy consumption Qhe

7153 kWh

8628 kWh

Pdh Tj = -15°C (if TOL<-20°C)

10.17

9.21

COP Tj = -15°C (if TOL<-20°C)

2.66

1.92

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

70 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200.2 %

141.6 %

Prated

12.3 kW

12.5 kW

SCOP

5.08

3.62

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.85 kW

11.06 kW

COP Tj = -7°C

3.11

2.15

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

6.79 kW

6.91 kW

COP Tj = +2°C

4.86

3.59

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

4.79 kW

4.64 kW

COP Tj = +7°C

6.98

5.07

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

3.73 kW

2.15 kW

COP Tj = 12°C

9.02

4.52

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

10.85 kW

11.06 kW

COP Tj = Tbiv

3.11

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.3 kW

10.97 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.8

1.98

WTOL

65 °C

65 °C

Poff

6 W

6 W

PTO

18 W

18 W

PSB

6 W

6 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

1.53 kW

Annual energy consumption Qhe

5003 kWh

7148 kWh

HPM3P16KWEWA
Configure model
Model name
HPM3P16KWEWA
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.56 kW

5.61 kW

COP

4.50

2.85

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

72 dB(A)

72 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

255.5 %

184 %

Prated

14.20 kW

14.50 kW

SCOP

6.46

4.68

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.20 kW

13.62 kW

COP Tj = +2°C

3.22

2.35

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

9.15 kW

9.35 kW

COP Tj = +7°C

5.41

3.94

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.24 kW

4.26 kW

COP Tj = 12°C

8.56

6.37

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

9.15 kW

9.35 kW

COP Tj = Tbiv

5.41

3.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.20 kW

13.62 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.22

2.35

WTOL

65.00 °C

65.00 °C

Poff

6.00 W

13.00 W

PTO

18.00 W

20.00 W

PSB

6.00 W

13.00 W

PCK

0.00 W

0.00 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.91 kW

Annual energy consumption Qhe

2935 kWh

4153 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

72 dB(A)

72 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

170.9 %

124.3 %

Prated

15.10 kW

13.50 kW

SCOP

4.35

3.18

Tbiv

-15.00 °C

-15.00 °C

TOL

-22.00 °C

-22.00 °C

Pdh Tj = -7°C

9.26 kW

8.43 kW

COP Tj = -7°C

3.59

2.77

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

5.76 kW

5.20 kW

COP Tj = +2°C

5.35

3.74

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.76 kW

3.53 kW

COP Tj = +7°C

7.04

5.19

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.72 kW

3.61 kW

COP Tj = 12°C

8.78

6.61

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

12.30 kW

11.03 kW

COP Tj = Tbiv

2.58

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.43 kW

7.52 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.00

1.30

WTOL

65.00 °C

65.00 °C

Poff

6.00 W

6.00 W

PTO

18.00 W

18.00 W

PSB

6.00 W

6.00 W

PCK

0.00 W

0.00 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.67 kW

5.98 kW

Annual energy consumption Qhe

8546 kWh

10473 kWh

Pdh Tj = -15°C (if TOL<-20°C)

12.30

11.03

COP Tj = -15°C (if TOL<-20°C)

2.58

1.85

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

72 dB(A)

72 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190.5 %

140.7 %

Prated

15.20 kW

14.70 kW

SCOP

4.84

3.59

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.49 kW

13.03 kW

COP Tj = -7°C

2.87

2.16

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

8.59 kW

8.50 kW

COP Tj = +2°C

4.53

3.55

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

5.55 kW

5.27 kW

COP Tj = +7°C

7.01

5.05

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.73 kW

2.15 kW

COP Tj = 12°C

9.02

4.52

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

13.49 kW

13.03 kW

COP Tj = Tbiv

2.87

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.05 kW

12.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.65

1.94

WTOL

65.00 °C

65.00 °C

Poff

6.00 W

6.00 W

PTO

18.00 W

18.00 W

PSB

6.00 W

6.00 W

PCK

0.00 W

0.00 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.15 kW

2.63 kW

Annual energy consumption Qhe

6509 kWh

8460 kWh