5,000 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
22.30 kW
22.10 kW
El input
5.13 kW
8.33 kW
COP
4.35
2.65
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
73 dB(A)
73 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
234 %
161 %
Prated
21.90 kW
22.01 kW
SCOP
5.85
4.09
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
21.81 kW
22.01 kW
COP Tj = +2°C
3.31
2.12
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
14.08 kW
14.15 kW
COP Tj = +7°C
5.20
3.50
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
6.44 kW
6.38 kW
COP Tj = 12°C
7.50
5.34
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
14.08 kW
14.15 kW
COP Tj = Tbiv
5.20
3.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
21.81 kW
22.01 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.31
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
18 W
18 W
PTO
96 W
96 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.09 kW
0.00 kW
Annual energy consumption Qhe
4945 kWh
7180 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
73 dB(A)
73 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
146 %
102 %
Prated
21.40 kW
22.36 kW
SCOP
3.72
2.62
Tbiv
-15 °C
-7 °C
TOL
-22 °C
-15 °C
Pdh Tj = -7°C
13.30 kW
13.53 kW
COP Tj = -7°C
3.12
2.07
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
8.25 kW
8.61 kW
COP Tj = +2°C
4.42
3.70
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.45 kW
5.21 kW
COP Tj = +7°C
5.87
4.49
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
3.98 kW
3.74 kW
COP Tj = 12°C
7.19
5.76
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
17.46 kW
13.53 kW
COP Tj = Tbiv
2.36
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.27 kW
13.78 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.69
1.24
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
96 W
96 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
8.13 kW
22.36 kW
Annual energy consumption Qhe
14179 kWh
21067 kWh
Pdh Tj = -15°C (if TOL<-20°C)
17.46
13.78
COP Tj = -15°C (if TOL<-20°C)
2.36
1.24
Cdh Tj = -15 °C
0.90
0.90
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
73 dB(A)
73 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
126 %
Prated
22.31 kW
22.43 kW
SCOP
4.53
3.22
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
19.72 kW
19.82 kW
COP Tj = -7°C
2.74
1.74
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
12.03 kW
11.89 kW
COP Tj = +2°C
4.41
3.32
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
8.00 kW
7.97 kW
COP Tj = +7°C
6.29
4.66
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
3.79 kW
3.60 kW
COP Tj = 12°C
7.14
5.32
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
19.72 kW
19.82 kW
COP Tj = Tbiv
2.74
1.74
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
20.33 kW
13.81 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.35
1.08
WTOL
60 °C
60 °C
Poff
18 W
18 W
PTO
96 W
96 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.97 kW
8.60 kW
Annual energy consumption Qhe
10180 kWh
14390 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
29.93 kW
29.68 kW
El input
8.02 kW
12.97 kW
COP
3.73
2.29
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
77 dB(A)
77 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
213 %
163 %
Prated
30.44 kW
29.73 kW
SCOP
5.39
4.15
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
26.29 kW
26.41 kW
COP Tj = +2°C
2.94
1.99
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
19.57 kW
19.11 kW
COP Tj = +7°C
4.75
3.37
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
8.90 kW
8.92 kW
COP Tj = 12°C
7.53
6.09
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
19.57 kW
19.11 kW
COP Tj = Tbiv
4.75
3.37
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
26.29 kW
26.41 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.94
1.99
WTOL
60 °C
60 °C
Poff
18 W
18 W
PTO
96 W
96 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.15 kW
3.32 kW
Annual energy consumption Qhe
7540 kWh
9580 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
77 dB(A)
77 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
138 %
100 %
Prated
29.13 kW
30.41 kW
SCOP
3.52
2.56
Tbiv
-10 °C
-7 °C
TOL
-22 °C
-15 °C
Pdh Tj = -7°C
18.49 kW
18.40 kW
COP Tj = -7°C
3.07
2.10
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
11.88 kW
11.22 kW
COP Tj = +2°C
4.42
3.51
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
7.53 kW
7.42 kW
COP Tj = +7°C
6.15
5.18
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
4.11 kW
3.64 kW
COP Tj = 12°C
6.87
5.73
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
19.93 kW
18.40 kW
COP Tj = Tbiv
2.44
2.10
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.17 kW
13.06 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.67
1.18
WTOL
60 °C
60 °C
Poff
18 W
18 W
PTO
96 W
96 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
15.96 kW
30.41 kW
Annual energy consumption Qhe
20390 kWh
29238 kWh
Pdh Tj = -15°C (if TOL<-20°C)
18.61
13.06
COP Tj = -15°C (if TOL<-20°C)
2.24
1.18
Cdh Tj = -15 °C
0.90
0.90
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
77 dB(A)
77 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
123 %
Prated
29.18 kW
29.69 kW
SCOP
4.19
3.14
Tbiv
-5 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
21.90 kW
20.11 kW
COP Tj = -7°C
2.54
1.63
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
16.16 kW
16.49 kW
COP Tj = +2°C
4.16
3.09
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
10.64 kW
10.50 kW
COP Tj = +7°C
6.38
4.75
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
4.54 kW
4.64 kW
COP Tj = 12°C
7.72
5.91
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
23.51 kW
23.97 kW
COP Tj = Tbiv
2.71
2.02
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
20.37 kW
13.82 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.35
1.07
WTOL
60 °C
60 °C
Poff
18 W
18 W
PTO
96 W
96 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
8.75 kW
15.86 kW
Annual energy consumption Qhe
14165 kWh
19316.17 kWh