Certificate holders

Subtype

Hi-Therma Integra 14 16

Certificate Holder
Qingdao Hisense Hitachi Air-conditioning Systems Co.,Ltd.
Qianwangang Road
266555 Qingdao, Shandong
China
Registration number
011-1W0664
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Hi-Therma Integra 14 16
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,700 kg

Certification Date
29.11.2023
Testing basis
European KEYMARK Scheme for Heat Pumps Version 12 (2023-03)
Generate PDF Export model CSV
  • Number of models 4

Models

AHW-140HCDS1/AHS-140HCDSAA-23
Configure model
Model name
AHW-140HCDS1/AHS-140HCDSAA-23
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

13.00 kW

El input

2.92 kW

4.26 kW

COP

4.80

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

128 %

Prated

11.90 kW

11.70 kW

SCOP

4.61

3.29

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.50 kW

10.33 kW

COP Tj = -7°C

2.97

2.22

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.39 kW

6.35 kW

COP Tj = +2°C

4.40

3.04

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.21 kW

4.31 kW

COP Tj = +7°C

6.21

4.36

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.90 kW

3.76 kW

COP Tj = 12°C

7.42

6.25

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.50 kW

10.33 kW

COP Tj = Tbiv

2.97

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.82 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.65

1.91

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

5 W

5 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.08 kW

0.20 kW

Annual energy consumption Qhe

5320 kWh

7340 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

124 %

COP

3.00

Heating up time

1:44 h:min

Standby power input

40.1 W

Reference hot water temperature

48.7 °C

Mixed water at 40°C

260 l

AHW-140HEDS1/AHS-140HEDSAA-23
Configure model
Model name
AHW-140HEDS1/AHS-140HEDSAA-23
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

13.00 kW

El input

2.92 kW

4.26 kW

COP

4.80

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

128 %

Prated

11.90 kW

11.70 kW

SCOP

4.61

3.29

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.50 kW

10.33 kW

COP Tj = -7°C

2.97

2.22

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.39 kW

6.35 kW

COP Tj = +2°C

4.40

3.04

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.21 kW

4.31 kW

COP Tj = +7°C

6.21

4.36

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.90 kW

3.76 kW

COP Tj = 12°C

7.42

6.25

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.50 kW

10.33 kW

COP Tj = Tbiv

2.97

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.82 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.65

1.91

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

5 W

5 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.08 kW

0.20 kW

Annual energy consumption Qhe

5320 kWh

7340 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

117 %

COP

2.80

Heating up time

1:45 h:min

Standby power input

53.5 W

Reference hot water temperature

48.7 °C

Mixed water at 40°C

260 l

AHW-160HCDS1/AHS-160HCDSAA-23
Configure model
Model name
AHW-160HCDS1/AHS-160HCDSAA-23
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

15.00 kW

El input

3.48 kW

5.08 kW

COP

4.60

2.95

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

128 %

Prated

13.00 kW

12.50 kW

SCOP

4.49

3.28

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.53 kW

11.10 kW

COP Tj = -7°C

2.86

2.24

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.98 kW

6.57 kW

COP Tj = +2°C

4.23

3.06

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.67 kW

4.30 kW

COP Tj = +7°C

6.21

4.33

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.90 kW

3.76 kW

COP Tj = 12°C

7.45

5.75

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.53 kW

11.10 kW

COP Tj = Tbiv

2.86

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.75 kW

12.03 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.88

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

5 W

5 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.25 kW

0.47 kW

Annual energy consumption Qhe

5999 kWh

7900 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

124 %

COP

3.00

Heating up time

1:44 h:min

Standby power input

40.1 W

Reference hot water temperature

48.7 °C

Mixed water at 40°C

260 l

AHW-160HEDS1/AHS-160HEDSAA-23
Configure model
Model name
AHW-160HEDS1/AHS-160HEDSAA-23
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

15.00 kW

El input

3.48 kW

5.08 kW

COP

4.60

2.95

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

128 %

Prated

13.00 kW

12.50 kW

SCOP

4.49

3.28

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.53 kW

11.10 kW

COP Tj = -7°C

2.86

2.24

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.98 kW

6.57 kW

COP Tj = +2°C

4.23

3.06

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.67 kW

4.30 kW

COP Tj = +7°C

6.21

4.33

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.90 kW

3.76 kW

COP Tj = 12°C

7.45

5.75

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.53 kW

11.10 kW

COP Tj = Tbiv

2.86

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.75 kW

12.03 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.88

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

5 W

5 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.25 kW

0.47 kW

Annual energy consumption Qhe

5999 kWh

7900 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

117 %

COP

2.80

Heating up time

1:45 h:min

Standby power input

53.5 W

Reference hot water temperature

48.7 °C

Mixed water at 40°C

260 l