2,500 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
17.35 kW
14.80 kW
El input
3.98 kW
5.57 kW
COP
4.37
2.66
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
137 %
Prated
14.58 kW
13.26 kW
SCOP
4.55
3.50
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.90 kW
11.73 kW
COP Tj = -7°C
3.08
2.03
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
7.79 kW
7.17 kW
COP Tj = +2°C
4.36
3.37
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
6.42 kW
6.22 kW
COP Tj = +7°C
5.82
4.73
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
7.38 kW
7.31 kW
COP Tj = 12°C
7.99
6.77
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
12.90 kW
11.73 kW
COP Tj = Tbiv
3.08
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14.20 kW
13.15 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.72
1.93
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
60 °C
60 °C
Poff
13 W
13 W
PTO
13 W
13 W
PSB
13 W
13 W
PCK
40 W
40 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.38 kW
0.11 kW
Annual energy consumption Qhe
6620 kWh
7826 kWh