0,630 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.52 kW
8.53 kW
El input
1.53 kW
2.96 kW
COP
4.27
2.88
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
dB(A)
dB(A)
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
138 %
Prated
6.50 kW
6.50 kW
SCOP
4.56
3.53
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.69 kW
5.77 kW
COP Tj = -7°C
2.92
2.28
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.62 kW
3.52 kW
COP Tj = +2°C
4.48
3.41
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.50 kW
2.53 kW
COP Tj = +7°C
5.87
4.50
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
2.58 kW
2.51 kW
COP Tj = 12°C
7.16
6.28
Cdh Tj = +12 °C
0.950
0.950
Pdh Tj = Tbiv
6.74 kW
6.70 kW
COP Tj = Tbiv
2.62
2.06
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.74 kW
6.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.62
2.06
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
65 °C
65 °C
Poff
19 W
19 W
PTO
20 W
20 W
PSB
19 W
19 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2943 kWh
3798 kWh