Certificate holders

Subtype

WSB 8-A-RME-AI/WSB 10-A-RME-AI

Certificate Holder
Max Weishaupt GmbH
Max-Weishaupt-Str. 14
88477 Schwendi
Germany
Registration number
011-1W0615
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
WSB 8-A-RME-AI/WSB 10-A-RME-AI
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,300 kg

Certification Date
05.05.2023
Testing basis
European KEYMARK Scheme for Heat Pumps Rev. 12 (as of 2023-03)
Generate PDF Export model CSV
  • Number of models 4

Models

WSB-8-A-RME-AI
Configure model
Model name
WSB-8-A-RME-AI
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.68 kW

5.58 kW

El input

1.42 kW

2.09 kW

COP

4.69

2.68

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

239 %

148 %

Prated

7.00 kW

7.00 kW

SCOP

6.06

3.78

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.10 kW

7.00 kW

COP Tj = +2°C

3.53

2.70

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.00 kW

4.70 kW

COP Tj = +7°C

5.00

3.42

Cdh Tj = +7 °C

0.990

1.000

Pdh Tj = 12°C

3.40 kW

2.70 kW

COP Tj = 12°C

8.54

4.41

Cdh Tj = +12 °C

0.990

0.950

Pdh Tj = Tbiv

7.10 kW

7.00 kW

COP Tj = Tbiv

3.53

2.70

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.10 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.53

2.70

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

12 W

12 W

PTO

4 W

4 W

PSB

14 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1544 kWh

2472 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

136 %

117 %

Prated

7.00 kW

7.00 kW

SCOP

3.46

2.99

Tbiv

-10 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.50 kW

4.20 kW

COP Tj = -7°C

3.10

2.00

Cdh Tj = -7 °C

1.000

0.970

Pdh Tj = +2°C

2.80 kW

3.10 kW

COP Tj = +2°C

4.50

4.12

Cdh Tj = +2 °C

1.000

0.960

Pdh Tj = +7°C

2.80 kW

2.80 kW

COP Tj = +7°C

5.63

4.70

Cdh Tj = +7 °C

0.900

0.950

Pdh Tj = 12°C

4.00 kW

2.70 kW

COP Tj = 12°C

8.10

5.37

Cdh Tj = +12 °C

0.900

0.950

Pdh Tj = Tbiv

4.70 kW

4.70 kW

COP Tj = Tbiv

2.80

1.70

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.50 kW

3.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.30

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

0.990

WTOL

60 °C

60 °C

Poff

12 W

12 W

PTO

4 W

4 W

PSB

14 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

7.00 kW

7.00 kW

Annual energy consumption Qhe

4983 kWh

5775 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.50

3.50

COP Tj = -15°C (if TOL<-20°C)

2.40

1.60

Cdh Tj = -15 °C

1.000

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

125 %

Prated

7.00 kW

6.50 kW

SCOP

4.74

3.21

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.77 kW

5.26 kW

COP Tj = -7°C

2.90

1.95

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.50 kW

4.50 kW

COP Tj = +2°C

4.62

3.31

Cdh Tj = +2 °C

1.000

0.990

Pdh Tj = +7°C

2.67 kW

2.72 kW

COP Tj = +7°C

5.76

3.97

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

3.40 kW

2.84 kW

COP Tj = 12°C

8.54

5.30

Cdh Tj = +12 °C

0.990

0.980

Pdh Tj = Tbiv

5.77 kW

5.26 kW

COP Tj = Tbiv

2.90

1.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.47 kW

3.18 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.68

1.20

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

0.993

WTOL

60 °C

60 °C

Poff

12 W

12 W

PTO

4 W

4 W

PSB

14 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.53 kW

3.32 kW

Annual energy consumption Qhe

3054 kWh

4184 kWh

WSB-8-A-RMEK-AI
Configure model
Model name
WSB-8-A-RMEK-AI
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.68 kW

5.58 kW

El input

1.42 kW

2.09 kW

COP

4.69

2.68

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

239 %

148 %

Prated

7.00 kW

7.00 kW

SCOP

6.06

3.78

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.10 kW

7.00 kW

COP Tj = +2°C

3.53

2.70

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.00 kW

4.70 kW

COP Tj = +7°C

5.00

3.42

Cdh Tj = +7 °C

0.990

1.000

Pdh Tj = 12°C

3.40 kW

2.70 kW

COP Tj = 12°C

8.54

4.41

Cdh Tj = +12 °C

0.990

0.950

Pdh Tj = Tbiv

7.10 kW

7.00 kW

COP Tj = Tbiv

3.53

2.70

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.10 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.53

2.70

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

12 W

12 W

PTO

4 W

4 W

PSB

14 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1544 kWh

2472 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

136 %

117 %

Prated

7.00 kW

7.00 kW

SCOP

3.46

2.99

Tbiv

-10 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.50 kW

4.20 kW

COP Tj = -7°C

3.10

2.00

Cdh Tj = -7 °C

1.000

0.970

Pdh Tj = +2°C

2.80 kW

3.10 kW

COP Tj = +2°C

4.50

4.12

Cdh Tj = +2 °C

1.000

0.960

Pdh Tj = +7°C

2.80 kW

2.80 kW

COP Tj = +7°C

5.63

4.70

Cdh Tj = +7 °C

0.900

0.950

Pdh Tj = 12°C

4.00 kW

2.70 kW

COP Tj = 12°C

8.10

5.37

Cdh Tj = +12 °C

0.900

0.950

Pdh Tj = Tbiv

4.70 kW

4.70 kW

COP Tj = Tbiv

2.80

1.70

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.50 kW

3.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.30

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

0.990

WTOL

60 °C

60 °C

Poff

12 W

12 W

PTO

4 W

4 W

PSB

14 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

7.00 kW

7.00 kW

Annual energy consumption Qhe

4983 kWh

5775 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.50

3.50

COP Tj = -15°C (if TOL<-20°C)

2.40

1.60

Cdh Tj = -15 °C

1.000

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

125 %

Prated

7.00 kW

6.50 kW

SCOP

4.74

3.21

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.77 kW

5.26 kW

COP Tj = -7°C

2.90

1.95

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.50 kW

4.50 kW

COP Tj = +2°C

4.62

3.31

Cdh Tj = +2 °C

1.000

0.990

Pdh Tj = +7°C

2.67 kW

2.72 kW

COP Tj = +7°C

5.76

3.97

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

3.40 kW

2.84 kW

COP Tj = 12°C

8.54

5.30

Cdh Tj = +12 °C

0.990

0.980

Pdh Tj = Tbiv

5.77 kW

5.26 kW

COP Tj = Tbiv

2.90

1.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.47 kW

3.18 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.68

1.20

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

0.993

WTOL

60 °C

60 °C

Poff

12 W

12 W

PTO

4 W

4 W

PSB

14 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.53 kW

3.32 kW

Annual energy consumption Qhe

3054 kWh

4184 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

131 %

COP

3.18

Heating up time

1:11 h:min

Standby power input

29.7 W

Reference hot water temperature

52.0 °C

Mixed water at 40°C

218 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

89 %

COP

2.16

Heating up time

1:31 h:min

Standby power input

38.3 W

Reference hot water temperature

52.0 °C

Mixed water at 40°C

214 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

111 %

COP

2.69

Heating up time

1:17 h:min

Standby power input

35.7 W

Reference hot water temperature

52.0 °C

Mixed water at 40°C

214 l

WSB-10-A-RME-AI
Configure model
Model name
WSB-10-A-RME-AI
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.52 kW

5.16 kW

El input

0.72 kW

1.83 kW

COP

4.86

2.82

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

263 %

176 %

Prated

10.00 kW

8.00 kW

SCOP

6.66

4.48

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.70 kW

9.10 kW

COP Tj = +2°C

3.58

2.48

Cdh Tj = +2 °C

1.000

0.990

Pdh Tj = +7°C

6.60 kW

5.10 kW

COP Tj = +7°C

5.89

3.67

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

3.40 kW

3.00 kW

COP Tj = 12°C

8.35

6.00

Cdh Tj = +12 °C

0.900

0.950

Pdh Tj = Tbiv

9.70 kW

9.10 kW

COP Tj = Tbiv

3.58

2.48

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.70 kW

9.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.58

2.48

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

11 W

11 W

PTO

4 W

4 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2005 kWh

2385 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

149 %

114 %

Prated

9.00 kW

7.00 kW

SCOP

3.79

2.93

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

5.50 kW

4.50 kW

COP Tj = -7°C

3.03

2.31

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.40 kW

3.10 kW

COP Tj = +2°C

5.25

4.12

Cdh Tj = +2 °C

1.000

0.960

Pdh Tj = +7°C

2.90 kW

2.60 kW

COP Tj = +7°C

7.17

5.11

Cdh Tj = +7 °C

0.900

0.950

Pdh Tj = 12°C

3.50 kW

3.30 kW

COP Tj = 12°C

9.29

7.53

Cdh Tj = +12 °C

0.900

0.950

Pdh Tj = Tbiv

5.50 kW

4.50 kW

COP Tj = Tbiv

3.03

2.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

3.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.18

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

11 W

11 W

PTO

4 W

4 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.00 kW

7.00 kW

Annual energy consumption Qhe

5847 kWh

5888 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

134 %

Prated

9.00 kW

8.00 kW

SCOP

4.92

3.42

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.40 kW

6.61 kW

COP Tj = -7°C

3.22

2.20

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

5.00 kW

4.34 kW

COP Tj = +2°C

4.74

3.34

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

3.42 kW

2.94 kW

COP Tj = +7°C

6.63

4.51

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

3.50 kW

3.07 kW

COP Tj = 12°C

8.40

5.70

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.40 kW

6.61 kW

COP Tj = Tbiv

3.22

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.04 kW

5.22 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

1.56

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

11 W

11 W

PTO

4 W

4 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.96 kW

2.78 kW

Annual energy consumption Qhe

3779 kWh

4833 kWh

WSB-10-A-RMEK-AI
Configure model
Model name
WSB-10-A-RMEK-AI
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.52 kW

5.16 kW

El input

0.72 kW

1.83 kW

COP

4.86

2.82

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

263 %

176 %

Prated

10.00 kW

8.00 kW

SCOP

6.66

4.48

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.70 kW

9.10 kW

COP Tj = +2°C

3.58

2.48

Cdh Tj = +2 °C

1.000

0.990

Pdh Tj = +7°C

6.60 kW

5.10 kW

COP Tj = +7°C

5.89

3.67

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

3.40 kW

3.00 kW

COP Tj = 12°C

8.35

6.00

Cdh Tj = +12 °C

0.900

0.950

Pdh Tj = Tbiv

9.70 kW

9.10 kW

COP Tj = Tbiv

3.58

2.48

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.70 kW

9.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.58

2.48

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

11 W

11 W

PTO

4 W

4 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2005 kWh

2385 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

149 %

114 %

Prated

9.00 kW

7.00 kW

SCOP

3.79

2.93

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

5.50 kW

4.50 kW

COP Tj = -7°C

3.03

2.31

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.40 kW

3.10 kW

COP Tj = +2°C

5.25

4.12

Cdh Tj = +2 °C

1.000

0.960

Pdh Tj = +7°C

2.90 kW

2.60 kW

COP Tj = +7°C

7.17

5.11

Cdh Tj = +7 °C

0.900

0.950

Pdh Tj = 12°C

3.50 kW

3.30 kW

COP Tj = 12°C

9.29

7.53

Cdh Tj = +12 °C

0.900

0.950

Pdh Tj = Tbiv

5.50 kW

4.50 kW

COP Tj = Tbiv

3.03

2.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

3.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.18

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

11 W

11 W

PTO

4 W

4 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.00 kW

7.00 kW

Annual energy consumption Qhe

5847 kWh

5888 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

134 %

Prated

9.00 kW

8.00 kW

SCOP

4.92

3.42

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.40 kW

6.61 kW

COP Tj = -7°C

3.22

2.20

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

5.00 kW

4.34 kW

COP Tj = +2°C

4.74

3.34

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

3.42 kW

2.94 kW

COP Tj = +7°C

6.63

4.51

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

3.50 kW

3.07 kW

COP Tj = 12°C

8.40

5.70

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.40 kW

6.61 kW

COP Tj = Tbiv

3.22

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.04 kW

5.22 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

1.56

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

11 W

11 W

PTO

4 W

4 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.96 kW

2.78 kW

Annual energy consumption Qhe

3779 kWh

4833 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

131 %

COP

3.18

Heating up time

1:11 h:min

Standby power input

29.7 W

Reference hot water temperature

52.0 °C

Mixed water at 40°C

218 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

89 %

COP

2.16

Heating up time

1:31 h:min

Standby power input

38.3 W

Reference hot water temperature

52.0 °C

Mixed water at 40°C

214 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

110 %

COP

2.69

Heating up time

1:17 h:min

Standby power input

35.7 W

Reference hot water temperature

52.0 °C

Mixed water at 40°C

214 l