1,300 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.68 kW
5.58 kW
El input
1.42 kW
2.09 kW
COP
4.69
2.68
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
239 %
148 %
Prated
7.00 kW
7.00 kW
SCOP
6.06
3.78
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.10 kW
7.00 kW
COP Tj = +2°C
3.53
2.70
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
5.00 kW
4.70 kW
COP Tj = +7°C
5.00
3.42
Cdh Tj = +7 °C
0.990
1.000
Pdh Tj = 12°C
3.40 kW
2.70 kW
COP Tj = 12°C
8.54
4.41
Cdh Tj = +12 °C
0.990
0.950
Pdh Tj = Tbiv
7.10 kW
7.00 kW
COP Tj = Tbiv
3.53
2.70
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.10 kW
7.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.53
2.70
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
4 W
4 W
PSB
14 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1544 kWh
2472 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
136 %
117 %
Prated
7.00 kW
7.00 kW
SCOP
3.46
2.99
Tbiv
-10 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
4.50 kW
4.20 kW
COP Tj = -7°C
3.10
2.00
Cdh Tj = -7 °C
1.000
0.970
Pdh Tj = +2°C
2.80 kW
3.10 kW
COP Tj = +2°C
4.50
4.12
Cdh Tj = +2 °C
1.000
0.960
Pdh Tj = +7°C
2.80 kW
2.80 kW
COP Tj = +7°C
5.63
4.70
Cdh Tj = +7 °C
0.900
0.950
Pdh Tj = 12°C
4.00 kW
2.70 kW
COP Tj = 12°C
8.10
5.37
Cdh Tj = +12 °C
0.900
0.950
Pdh Tj = Tbiv
4.70 kW
4.70 kW
COP Tj = Tbiv
2.80
1.70
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.50 kW
3.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.30
1.30
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
0.990
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
4 W
4 W
PSB
14 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
7.00 kW
7.00 kW
Annual energy consumption Qhe
4983 kWh
5775 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.50
3.50
COP Tj = -15°C (if TOL<-20°C)
2.40
1.60
Cdh Tj = -15 °C
1.000
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
125 %
Prated
7.00 kW
6.50 kW
SCOP
4.74
3.21
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.77 kW
5.26 kW
COP Tj = -7°C
2.90
1.95
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
3.50 kW
4.50 kW
COP Tj = +2°C
4.62
3.31
Cdh Tj = +2 °C
1.000
0.990
Pdh Tj = +7°C
2.67 kW
2.72 kW
COP Tj = +7°C
5.76
3.97
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
3.40 kW
2.84 kW
COP Tj = 12°C
8.54
5.30
Cdh Tj = +12 °C
0.990
0.980
Pdh Tj = Tbiv
5.77 kW
5.26 kW
COP Tj = Tbiv
2.90
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.47 kW
3.18 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.68
1.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
0.993
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
4 W
4 W
PSB
14 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.53 kW
3.32 kW
Annual energy consumption Qhe
3054 kWh
4184 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.68 kW
5.58 kW
El input
1.42 kW
2.09 kW
COP
4.69
2.68
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
239 %
148 %
Prated
7.00 kW
7.00 kW
SCOP
6.06
3.78
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.10 kW
7.00 kW
COP Tj = +2°C
3.53
2.70
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
5.00 kW
4.70 kW
COP Tj = +7°C
5.00
3.42
Cdh Tj = +7 °C
0.990
1.000
Pdh Tj = 12°C
3.40 kW
2.70 kW
COP Tj = 12°C
8.54
4.41
Cdh Tj = +12 °C
0.990
0.950
Pdh Tj = Tbiv
7.10 kW
7.00 kW
COP Tj = Tbiv
3.53
2.70
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.10 kW
7.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.53
2.70
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
4 W
4 W
PSB
14 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1544 kWh
2472 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
136 %
117 %
Prated
7.00 kW
7.00 kW
SCOP
3.46
2.99
Tbiv
-10 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
4.50 kW
4.20 kW
COP Tj = -7°C
3.10
2.00
Cdh Tj = -7 °C
1.000
0.970
Pdh Tj = +2°C
2.80 kW
3.10 kW
COP Tj = +2°C
4.50
4.12
Cdh Tj = +2 °C
1.000
0.960
Pdh Tj = +7°C
2.80 kW
2.80 kW
COP Tj = +7°C
5.63
4.70
Cdh Tj = +7 °C
0.900
0.950
Pdh Tj = 12°C
4.00 kW
2.70 kW
COP Tj = 12°C
8.10
5.37
Cdh Tj = +12 °C
0.900
0.950
Pdh Tj = Tbiv
4.70 kW
4.70 kW
COP Tj = Tbiv
2.80
1.70
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.50 kW
3.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.30
1.30
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
0.990
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
4 W
4 W
PSB
14 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
7.00 kW
7.00 kW
Annual energy consumption Qhe
4983 kWh
5775 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.50
3.50
COP Tj = -15°C (if TOL<-20°C)
2.40
1.60
Cdh Tj = -15 °C
1.000
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
125 %
Prated
7.00 kW
6.50 kW
SCOP
4.74
3.21
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.77 kW
5.26 kW
COP Tj = -7°C
2.90
1.95
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
3.50 kW
4.50 kW
COP Tj = +2°C
4.62
3.31
Cdh Tj = +2 °C
1.000
0.990
Pdh Tj = +7°C
2.67 kW
2.72 kW
COP Tj = +7°C
5.76
3.97
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
3.40 kW
2.84 kW
COP Tj = 12°C
8.54
5.30
Cdh Tj = +12 °C
0.990
0.980
Pdh Tj = Tbiv
5.77 kW
5.26 kW
COP Tj = Tbiv
2.90
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.47 kW
3.18 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.68
1.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
0.993
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
4 W
4 W
PSB
14 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.53 kW
3.32 kW
Annual energy consumption Qhe
3054 kWh
4184 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
131 %
COP
3.18
Heating up time
1:11 h:min
Standby power input
29.7 W
Reference hot water temperature
52.0 °C
Mixed water at 40°C
218 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
89 %
COP
2.16
Heating up time
1:31 h:min
Standby power input
38.3 W
Reference hot water temperature
52.0 °C
Mixed water at 40°C
214 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
111 %
COP
2.69
Heating up time
1:17 h:min
Standby power input
35.7 W
Reference hot water temperature
52.0 °C
Mixed water at 40°C
214 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.52 kW
5.16 kW
El input
0.72 kW
1.83 kW
COP
4.86
2.82
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
263 %
176 %
Prated
10.00 kW
8.00 kW
SCOP
6.66
4.48
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.70 kW
9.10 kW
COP Tj = +2°C
3.58
2.48
Cdh Tj = +2 °C
1.000
0.990
Pdh Tj = +7°C
6.60 kW
5.10 kW
COP Tj = +7°C
5.89
3.67
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
3.40 kW
3.00 kW
COP Tj = 12°C
8.35
6.00
Cdh Tj = +12 °C
0.900
0.950
Pdh Tj = Tbiv
9.70 kW
9.10 kW
COP Tj = Tbiv
3.58
2.48
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.70 kW
9.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.58
2.48
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
4 W
4 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2005 kWh
2385 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
149 %
114 %
Prated
9.00 kW
7.00 kW
SCOP
3.79
2.93
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
5.50 kW
4.50 kW
COP Tj = -7°C
3.03
2.31
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
3.40 kW
3.10 kW
COP Tj = +2°C
5.25
4.12
Cdh Tj = +2 °C
1.000
0.960
Pdh Tj = +7°C
2.90 kW
2.60 kW
COP Tj = +7°C
7.17
5.11
Cdh Tj = +7 °C
0.900
0.950
Pdh Tj = 12°C
3.50 kW
3.30 kW
COP Tj = 12°C
9.29
7.53
Cdh Tj = +12 °C
0.900
0.950
Pdh Tj = Tbiv
5.50 kW
4.50 kW
COP Tj = Tbiv
3.03
2.31
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.00 kW
3.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.18
1.30
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
4 W
4 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.00 kW
7.00 kW
Annual energy consumption Qhe
5847 kWh
5888 kWh
Pdh Tj = -15°C (if TOL<-20°C)
COP Tj = -15°C (if TOL<-20°C)
Cdh Tj = -15 °C
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
194 %
134 %
Prated
9.00 kW
8.00 kW
SCOP
4.92
3.42
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.40 kW
6.61 kW
COP Tj = -7°C
3.22
2.20
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
5.00 kW
4.34 kW
COP Tj = +2°C
4.74
3.34
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
3.42 kW
2.94 kW
COP Tj = +7°C
6.63
4.51
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
3.50 kW
3.07 kW
COP Tj = 12°C
8.40
5.70
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.40 kW
6.61 kW
COP Tj = Tbiv
3.22
2.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.04 kW
5.22 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.82
1.56
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
4 W
4 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.96 kW
2.78 kW
Annual energy consumption Qhe
3779 kWh
4833 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.52 kW
5.16 kW
El input
0.72 kW
1.83 kW
COP
4.86
2.82
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
263 %
176 %
Prated
10.00 kW
8.00 kW
SCOP
6.66
4.48
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.70 kW
9.10 kW
COP Tj = +2°C
3.58
2.48
Cdh Tj = +2 °C
1.000
0.990
Pdh Tj = +7°C
6.60 kW
5.10 kW
COP Tj = +7°C
5.89
3.67
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
3.40 kW
3.00 kW
COP Tj = 12°C
8.35
6.00
Cdh Tj = +12 °C
0.900
0.950
Pdh Tj = Tbiv
9.70 kW
9.10 kW
COP Tj = Tbiv
3.58
2.48
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.70 kW
9.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.58
2.48
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
4 W
4 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2005 kWh
2385 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
149 %
114 %
Prated
9.00 kW
7.00 kW
SCOP
3.79
2.93
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
5.50 kW
4.50 kW
COP Tj = -7°C
3.03
2.31
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
3.40 kW
3.10 kW
COP Tj = +2°C
5.25
4.12
Cdh Tj = +2 °C
1.000
0.960
Pdh Tj = +7°C
2.90 kW
2.60 kW
COP Tj = +7°C
7.17
5.11
Cdh Tj = +7 °C
0.900
0.950
Pdh Tj = 12°C
3.50 kW
3.30 kW
COP Tj = 12°C
9.29
7.53
Cdh Tj = +12 °C
0.900
0.950
Pdh Tj = Tbiv
5.50 kW
4.50 kW
COP Tj = Tbiv
3.03
2.31
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.00 kW
3.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.18
1.30
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
4 W
4 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.00 kW
7.00 kW
Annual energy consumption Qhe
5847 kWh
5888 kWh
Pdh Tj = -15°C (if TOL<-20°C)
COP Tj = -15°C (if TOL<-20°C)
Cdh Tj = -15 °C
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
194 %
134 %
Prated
9.00 kW
8.00 kW
SCOP
4.92
3.42
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.40 kW
6.61 kW
COP Tj = -7°C
3.22
2.20
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
5.00 kW
4.34 kW
COP Tj = +2°C
4.74
3.34
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
3.42 kW
2.94 kW
COP Tj = +7°C
6.63
4.51
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
3.50 kW
3.07 kW
COP Tj = 12°C
8.40
5.70
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.40 kW
6.61 kW
COP Tj = Tbiv
3.22
2.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.04 kW
5.22 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.82
1.56
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
4 W
4 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.96 kW
2.78 kW
Annual energy consumption Qhe
3779 kWh
4833 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
131 %
COP
3.18
Heating up time
1:11 h:min
Standby power input
29.7 W
Reference hot water temperature
52.0 °C
Mixed water at 40°C
218 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
89 %
COP
2.16
Heating up time
1:31 h:min
Standby power input
38.3 W
Reference hot water temperature
52.0 °C
Mixed water at 40°C
214 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
110 %
COP
2.69
Heating up time
1:17 h:min
Standby power input
35.7 W
Reference hot water temperature
52.0 °C
Mixed water at 40°C
214 l