Certificate holders

Subtype

Aquarea Split 9-12 kW T-CAP (K Series)

Certificate Holder
Panasonic Marketing Europe GmbH
Hagenauer Strasse 43, Wiesbaden
65203 Wiesbaden
Germany
Registration number
011-1W0606
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Aquarea Split 9-12 kW T-CAP (K Series)
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,600 kg

Certification Date
28.04.2023
Testing basis
HP KEYMARK certification scheme rules V12
Generate PDF Export model CSV
  • Number of models 16

Models

WH-ADC0912K6E5 / WH-UXZ09KE5
Configure model
Model name
WH-ADC0912K6E5 / WH-UXZ09KE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

9.00 kW

El input

1.79 kW

2.93 kW

COP

5.03

3.07

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.83 kW

Cooling capacity

8.80

EER

3.11

EN 14825

+7°C/+12°C

Pdesignc

8.00 kW

SEER

4.12

Pdc Tj = 35°C

8.00 kW

EER Tj = 35°C

3.19

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

5.89 kW

EER Tj = 30°C

3.91

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

3.79 kW

EER Tj = 25°C

4.25

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

1.68 kW

EER Tj = 20°C

5.13

Cdc Tj = 20 °C

1.000

Poff

10 W

PTO

0 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

679 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

171 %

Prated

9.00 kW

9.00 kW

SCOP

6.47

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.67

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.79 kW

5.91 kW

COP Tj = +7°C

5.88

3.75

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.28 kW

5.97 kW

COP Tj = 12°C

7.85

5.50

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.67

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.67

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1859 kWh

2772 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

127 %

Prated

11.00 kW

11.00 kW

SCOP

4.31

3.26

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.66 kW

6.66 kW

COP Tj = -7°C

3.37

2.64

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

4.75 kW

4.47 kW

COP Tj = +2°C

5.32

3.93

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.47 kW

5.25 kW

COP Tj = +7°C

6.69

5.04

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.32 kW

6.16 kW

COP Tj = 12°C

8.14

6.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.97 kW

8.97 kW

COP Tj = Tbiv

2.70

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.98 kW

8.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.02 kW

3.00 kW

Annual energy consumption Qhe

6289 kWh

8327 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.97

8.97

COP Tj = -15°C (if TOL<-20°C)

2.70

2.09

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

140 %

Prated

9.00 kW

9.00 kW

SCOP

4.96

3.57

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.96 kW

7.96 kW

COP Tj = -7°C

3.04

2.33

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.85 kW

4.85 kW

COP Tj = +2°C

4.93

3.46

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.37 kW

5.09 kW

COP Tj = +7°C

6.26

4.48

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.33 kW

6.09 kW

COP Tj = 12°C

8.19

6.02

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

2.90

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3747 kWh

5208 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

134 %

COP

3.35

Heating up time

0:50 h:min

Standby power input

31.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

90 %

COP

2.26

Heating up time

0:50 h:min

Standby power input

44.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

114 %

COP

2.86

Heating up time

0:50 h:min

Standby power input

34.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

WH-ADC0912K6E5UK / WH-UXZ09KE5
Configure model
Model name
WH-ADC0912K6E5UK / WH-UXZ09KE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

9.00 kW

El input

1.79 kW

2.93 kW

COP

5.03

3.07

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.83 kW

Cooling capacity

8.80

EER

3.11

EN 14825

+7°C/+12°C

Pdesignc

8.00 kW

SEER

4.12

Pdc Tj = 35°C

8.00 kW

EER Tj = 35°C

3.19

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

5.89 kW

EER Tj = 30°C

3.91

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

3.79 kW

EER Tj = 25°C

4.25

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

1.68 kW

EER Tj = 20°C

5.13

Cdc Tj = 20 °C

1.000

Poff

10 W

PTO

0 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

679 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

171 %

Prated

9.00 kW

9.00 kW

SCOP

6.47

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.67

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.79 kW

5.91 kW

COP Tj = +7°C

5.88

3.75

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.28 kW

5.97 kW

COP Tj = 12°C

7.85

5.50

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.67

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.67

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1859 kWh

2772 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

127 %

Prated

11.00 kW

11.00 kW

SCOP

4.31

3.26

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.66 kW

6.66 kW

COP Tj = -7°C

3.37

2.64

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

4.75 kW

4.47 kW

COP Tj = +2°C

5.32

3.93

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.47 kW

5.25 kW

COP Tj = +7°C

6.69

5.04

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.32 kW

6.16 kW

COP Tj = 12°C

8.14

6.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.97 kW

8.97 kW

COP Tj = Tbiv

2.70

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.98 kW

8.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.02 kW

3.00 kW

Annual energy consumption Qhe

6289 kWh

8327 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.97

8.97

COP Tj = -15°C (if TOL<-20°C)

2.70

2.09

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

140 %

Prated

9.00 kW

9.00 kW

SCOP

4.96

3.57

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.96 kW

7.96 kW

COP Tj = -7°C

3.04

2.33

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.85 kW

4.85 kW

COP Tj = +2°C

4.93

3.46

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.37 kW

5.09 kW

COP Tj = +7°C

6.26

4.48

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.33 kW

6.09 kW

COP Tj = 12°C

8.19

6.02

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

2.90

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3747 kWh

5208 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

134 %

COP

3.35

Heating up time

0:50 h:min

Standby power input

31.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

90 %

COP

2.26

Heating up time

0:50 h:min

Standby power input

44.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

114 %

COP

2.86

Heating up time

0:50 h:min

Standby power input

34.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

WH-ADC0912K6E5AN / WH-UXZ09KE5
Configure model
Model name
WH-ADC0912K6E5AN / WH-UXZ09KE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

9.00 kW

El input

1.79 kW

2.93 kW

COP

5.03

3.07

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.83 kW

Cooling capacity

8.80

EER

3.11

EN 14825

+7°C/+12°C

Pdesignc

8.00 kW

SEER

4.12

Pdc Tj = 35°C

8.00 kW

EER Tj = 35°C

3.19

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

5.89 kW

EER Tj = 30°C

3.91

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

3.79 kW

EER Tj = 25°C

4.25

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

1.68 kW

EER Tj = 20°C

5.13

Cdc Tj = 20 °C

1.000

Poff

10 W

PTO

0 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

679 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

171 %

Prated

9.00 kW

9.00 kW

SCOP

6.47

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.67

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.79 kW

5.91 kW

COP Tj = +7°C

5.88

3.75

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.28 kW

5.97 kW

COP Tj = 12°C

7.85

5.50

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.67

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.67

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1859 kWh

2772 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

127 %

Prated

11.00 kW

11.00 kW

SCOP

4.31

3.26

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.66 kW

6.66 kW

COP Tj = -7°C

3.37

2.64

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

4.75 kW

4.47 kW

COP Tj = +2°C

5.32

3.93

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.47 kW

5.25 kW

COP Tj = +7°C

6.69

5.04

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.32 kW

6.16 kW

COP Tj = 12°C

8.14

6.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.97 kW

8.97 kW

COP Tj = Tbiv

2.70

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.98 kW

8.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.02 kW

3.00 kW

Annual energy consumption Qhe

6289 kWh

8327 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.97

8.97

COP Tj = -15°C (if TOL<-20°C)

2.70

2.09

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

140 %

Prated

9.00 kW

9.00 kW

SCOP

4.96

3.57

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.96 kW

7.96 kW

COP Tj = -7°C

3.04

2.33

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.85 kW

4.85 kW

COP Tj = +2°C

4.93

3.46

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.37 kW

5.09 kW

COP Tj = +7°C

6.26

4.48

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.33 kW

6.09 kW

COP Tj = 12°C

8.19

6.02

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

2.90

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3747 kWh

5208 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

134 %

COP

3.35

Heating up time

0:50 h:min

Standby power input

31.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

90 %

COP

2.26

Heating up time

0:50 h:min

Standby power input

44.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

114 %

COP

2.86

Heating up time

0:50 h:min

Standby power input

34.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

WH-ADC0912K6E5 / WH-UXZ12KE5
Configure model
Model name
WH-ADC0912K6E5 / WH-UXZ12KE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.10 kW

12.10 kW

El input

2.50 kW

3.98 kW

COP

4.84

3.04

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.99 kW

Cooling capacity

10.70

EER

2.68

EN 14825

+7°C/+12°C

Pdesignc

10.00 kW

SEER

4.44

Pdc Tj = 35°C

10.00 kW

EER Tj = 35°C

2.87

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

7.37 kW

EER Tj = 30°C

3.96

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

4.74 kW

EER Tj = 25°C

4.86

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

2.11 kW

EER Tj = 20°C

5.68

Cdc Tj = 20 °C

1.000

Poff

10 W

PTO

0 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

789 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

171 %

Prated

9.00 kW

9.00 kW

SCOP

6.47

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.67

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.79 kW

5.91 kW

COP Tj = +7°C

5.88

3.75

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.28 kW

5.97 kW

COP Tj = 12°C

7.85

5.50

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.67

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.67

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1859 kWh

2772 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

127 %

Prated

11.00 kW

11.00 kW

SCOP

4.31

3.26

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.66 kW

6.66 kW

COP Tj = -7°C

3.37

2.64

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

4.75 kW

4.47 kW

COP Tj = +2°C

5.32

3.93

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.47 kW

5.25 kW

COP Tj = +7°C

6.69

5.04

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.32 kW

6.16 kW

COP Tj = 12°C

8.14

6.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.97 kW

8.97 kW

COP Tj = Tbiv

2.70

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.98 kW

8.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.02 kW

3.00 kW

Annual energy consumption Qhe

6289 kWh

8327 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.97

8.97

COP Tj = -15°C (if TOL<-20°C)

2.70

2.09

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

140 %

Prated

9.00 kW

9.00 kW

SCOP

4.96

3.57

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.96 kW

7.96 kW

COP Tj = -7°C

3.04

2.33

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.85 kW

4.85 kW

COP Tj = +2°C

4.93

3.46

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.37 kW

5.09 kW

COP Tj = +7°C

6.26

4.48

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.33 kW

6.09 kW

COP Tj = 12°C

8.19

6.02

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

2.90

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3747 kWh

5208 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

134 %

COP

3.35

Heating up time

0:50 h:min

Standby power input

31.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

90 %

COP

2.26

Heating up time

0:50 h:min

Standby power input

44.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

114 %

COP

2.86

Heating up time

0:50 h:min

Standby power input

34.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

WH-ADC0912K6E5UK / WH-UXZ12KE5
Configure model
Model name
WH-ADC0912K6E5UK / WH-UXZ12KE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.10 kW

12.10 kW

El input

2.50 kW

3.98 kW

COP

4.84

3.04

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.99 kW

Cooling capacity

10.70

EER

2.68

EN 14825

+7°C/+12°C

Pdesignc

10.00 kW

SEER

4.44

Pdc Tj = 35°C

10.00 kW

EER Tj = 35°C

2.87

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

7.37 kW

EER Tj = 30°C

3.96

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

4.74 kW

EER Tj = 25°C

4.86

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

2.11 kW

EER Tj = 20°C

5.68

Cdc Tj = 20 °C

1.000

Poff

10 W

PTO

0 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

789 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

171 %

Prated

9.00 kW

9.00 kW

SCOP

6.47

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.67

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.79 kW

5.91 kW

COP Tj = +7°C

5.88

3.75

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.28 kW

5.97 kW

COP Tj = 12°C

7.85

5.50

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.67

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.67

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1859 kWh

2772 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

127 %

Prated

11.00 kW

11.00 kW

SCOP

4.31

3.26

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.66 kW

6.66 kW

COP Tj = -7°C

3.37

2.64

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

4.75 kW

4.47 kW

COP Tj = +2°C

5.32

3.93

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.47 kW

5.25 kW

COP Tj = +7°C

6.69

5.04

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.32 kW

6.16 kW

COP Tj = 12°C

8.14

6.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.97 kW

8.97 kW

COP Tj = Tbiv

2.70

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.98 kW

8.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.02 kW

3.00 kW

Annual energy consumption Qhe

6289 kWh

8327 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.97

8.97

COP Tj = -15°C (if TOL<-20°C)

2.70

2.09

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

140 %

Prated

9.00 kW

9.00 kW

SCOP

4.96

3.57

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.96 kW

7.96 kW

COP Tj = -7°C

3.04

2.33

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.85 kW

4.85 kW

COP Tj = +2°C

4.93

3.46

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.37 kW

5.09 kW

COP Tj = +7°C

6.26

4.48

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.33 kW

6.09 kW

COP Tj = 12°C

8.19

6.02

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

2.90

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3747 kWh

5208 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

134 %

COP

3.35

Heating up time

0:50 h:min

Standby power input

31.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

90 %

COP

2.26

Heating up time

0:50 h:min

Standby power input

44.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

114 %

COP

2.86

Heating up time

0:50 h:min

Standby power input

34.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

WH-ADC0912K6E5AN / WH-UXZ12KE5
Configure model
Model name
WH-ADC0912K6E5AN / WH-UXZ12KE5
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.10 kW

12.10 kW

El input

2.50 kW

3.98 kW

COP

4.84

3.04

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.99 kW

Cooling capacity

10.70

EER

2.68

EN 14825

+7°C/+12°C

Pdesignc

10.00 kW

SEER

4.44

Pdc Tj = 35°C

10.00 kW

EER Tj = 35°C

2.87

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

7.37 kW

EER Tj = 30°C

3.96

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

4.74 kW

EER Tj = 25°C

4.86

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

2.11 kW

EER Tj = 20°C

5.68

Cdc Tj = 20 °C

1.000

Poff

10 W

PTO

0 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

789 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

171 %

Prated

9.00 kW

9.00 kW

SCOP

6.47

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.67

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.79 kW

5.91 kW

COP Tj = +7°C

5.88

3.75

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.28 kW

5.97 kW

COP Tj = 12°C

7.85

5.50

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.67

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.67

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1859 kWh

2772 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

127 %

Prated

11.00 kW

11.00 kW

SCOP

4.31

3.26

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.66 kW

6.66 kW

COP Tj = -7°C

3.37

2.64

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

4.75 kW

4.47 kW

COP Tj = +2°C

5.32

3.93

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.47 kW

5.25 kW

COP Tj = +7°C

6.69

5.04

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.32 kW

6.16 kW

COP Tj = 12°C

8.14

6.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.97 kW

8.97 kW

COP Tj = Tbiv

2.70

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.98 kW

8.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.02 kW

3.00 kW

Annual energy consumption Qhe

6289 kWh

8327 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.97

8.97

COP Tj = -15°C (if TOL<-20°C)

2.70

2.09

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

140 %

Prated

9.00 kW

9.00 kW

SCOP

4.96

3.57

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.96 kW

7.96 kW

COP Tj = -7°C

3.04

2.33

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.85 kW

4.85 kW

COP Tj = +2°C

4.93

3.46

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.37 kW

5.09 kW

COP Tj = +7°C

6.26

4.48

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.33 kW

6.09 kW

COP Tj = 12°C

8.19

6.02

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

2.90

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3747 kWh

5208 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

134 %

COP

3.35

Heating up time

0:50 h:min

Standby power input

31.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

90 %

COP

2.26

Heating up time

0:50 h:min

Standby power input

44.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

114 %

COP

2.86

Heating up time

0:50 h:min

Standby power input

34.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

WH-ADC0912K9E8 / WH-UXZ09KE8
Configure model
Model name
WH-ADC0912K9E8 / WH-UXZ09KE8
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

9.00 kW

El input

1.79 kW

2.93 kW

COP

5.03

3.07

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.83 kW

Cooling capacity

8.80

EER

3.11

EN 14825

+7°C/+12°C

Pdesignc

8.00 kW

SEER

4.12

Pdc Tj = 35°C

8.00 kW

EER Tj = 35°C

3.19

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

5.89 kW

EER Tj = 30°C

3.91

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

3.79 kW

EER Tj = 25°C

4.25

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

1.68 kW

EER Tj = 20°C

5.13

Cdc Tj = 20 °C

1.000

Poff

10 W

PTO

0 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

679 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

171 %

Prated

9.00 kW

9.00 kW

SCOP

6.47

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.67

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.79 kW

5.91 kW

COP Tj = +7°C

5.88

3.75

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.28 kW

5.97 kW

COP Tj = 12°C

7.85

5.50

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.67

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.67

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1859 kWh

2772 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

127 %

Prated

11.00 kW

11.00 kW

SCOP

4.31

3.26

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.66 kW

6.66 kW

COP Tj = -7°C

3.37

2.64

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

4.75 kW

4.47 kW

COP Tj = +2°C

5.32

3.93

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.47 kW

5.25 kW

COP Tj = +7°C

6.69

5.04

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.32 kW

6.16 kW

COP Tj = 12°C

8.14

6.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.97 kW

8.97 kW

COP Tj = Tbiv

2.70

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.98 kW

8.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.02 kW

3.00 kW

Annual energy consumption Qhe

6289 kWh

8327 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.97

8.97

COP Tj = -15°C (if TOL<-20°C)

2.70

2.09

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

140 %

Prated

9.00 kW

9.00 kW

SCOP

4.96

3.57

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.96 kW

7.96 kW

COP Tj = -7°C

3.04

2.33

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.85 kW

4.85 kW

COP Tj = +2°C

4.93

3.46

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.37 kW

5.09 kW

COP Tj = +7°C

6.26

4.48

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.33 kW

6.09 kW

COP Tj = 12°C

8.19

6.02

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

2.90

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3747 kWh

5208 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

134 %

COP

3.35

Heating up time

0:50 h:min

Standby power input

31.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

90 %

COP

2.26

Heating up time

0:50 h:min

Standby power input

44.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

114 %

COP

2.86

Heating up time

0:50 h:min

Standby power input

34.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

WH-ADC0912K9E8AN / WH-UXZ09KE8
Configure model
Model name
WH-ADC0912K9E8AN / WH-UXZ09KE8
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

9.00 kW

El input

1.79 kW

2.93 kW

COP

5.03

3.07

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.83 kW

Cooling capacity

8.80

EER

3.11

EN 14825

+7°C/+12°C

Pdesignc

8.00 kW

SEER

4.12

Pdc Tj = 35°C

8.00 kW

EER Tj = 35°C

3.19

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

5.89 kW

EER Tj = 30°C

3.91

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

3.79 kW

EER Tj = 25°C

4.25

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

1.68 kW

EER Tj = 20°C

5.13

Cdc Tj = 20 °C

1.000

Poff

10 W

PTO

0 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

679 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

171 %

Prated

9.00 kW

9.00 kW

SCOP

6.47

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.67

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.79 kW

5.91 kW

COP Tj = +7°C

5.88

3.75

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.28 kW

5.97 kW

COP Tj = 12°C

7.85

5.50

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.67

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.67

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1859 kWh

2772 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

127 %

Prated

11.00 kW

11.00 kW

SCOP

4.31

3.26

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.66 kW

6.66 kW

COP Tj = -7°C

3.37

2.64

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

4.75 kW

4.47 kW

COP Tj = +2°C

5.32

3.93

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.47 kW

5.25 kW

COP Tj = +7°C

6.69

5.04

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.32 kW

6.16 kW

COP Tj = 12°C

8.14

6.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.97 kW

8.97 kW

COP Tj = Tbiv

2.70

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.98 kW

8.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.02 kW

3.00 kW

Annual energy consumption Qhe

6289 kWh

8327 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.97

8.97

COP Tj = -15°C (if TOL<-20°C)

2.70

2.09

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

140 %

Prated

9.00 kW

9.00 kW

SCOP

4.96

3.57

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.96 kW

7.96 kW

COP Tj = -7°C

3.04

2.33

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.85 kW

4.85 kW

COP Tj = +2°C

4.93

3.46

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.37 kW

5.09 kW

COP Tj = +7°C

6.26

4.48

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.33 kW

6.09 kW

COP Tj = 12°C

8.19

6.02

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

2.90

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3747 kWh

5208 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

134 %

COP

3.35

Heating up time

0:50 h:min

Standby power input

31.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

90 %

COP

2.26

Heating up time

0:50 h:min

Standby power input

44.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

114 %

COP

2.86

Heating up time

0:50 h:min

Standby power input

34.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

WH-ADC0912K9E8 / WH-UXZ12KE8
Configure model
Model name
WH-ADC0912K9E8 / WH-UXZ12KE8
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.10 kW

12.10 kW

El input

2.50 kW

3.98 kW

COP

4.84

3.04

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.99 kW

Cooling capacity

10.70

EER

2.68

EN 14825

+7°C/+12°C

Pdesignc

10.00 kW

SEER

4.44

Pdc Tj = 35°C

10.00 kW

EER Tj = 35°C

2.87

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

7.37 kW

EER Tj = 30°C

3.96

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

4.74 kW

EER Tj = 25°C

4.86

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

2.11 kW

EER Tj = 20°C

5.68

Cdc Tj = 20 °C

1.000

Poff

10 W

PTO

0 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

789 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

171 %

Prated

9.00 kW

9.00 kW

SCOP

6.47

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.67

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.79 kW

5.91 kW

COP Tj = +7°C

5.88

3.75

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.28 kW

5.97 kW

COP Tj = 12°C

7.85

5.50

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.67

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.67

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1859 kWh

2772 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

127 %

Prated

11.00 kW

11.00 kW

SCOP

4.31

3.26

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.66 kW

6.66 kW

COP Tj = -7°C

3.37

2.64

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

4.75 kW

4.47 kW

COP Tj = +2°C

5.32

3.93

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.47 kW

5.25 kW

COP Tj = +7°C

6.69

5.04

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.32 kW

6.16 kW

COP Tj = 12°C

8.14

6.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.97 kW

8.97 kW

COP Tj = Tbiv

2.70

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.98 kW

8.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.02 kW

3.00 kW

Annual energy consumption Qhe

6289 kWh

8327 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.97

8.97

COP Tj = -15°C (if TOL<-20°C)

2.70

2.09

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

135 %

Prated

12.00 kW

12.00 kW

SCOP

4.58

3.46

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.62 kW

10.64 kW

COP Tj = -7°C

2.51

2.23

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

6.46 kW

6.49 kW

COP Tj = +2°C

4.53

3.24

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

5.50 kW

5.22 kW

COP Tj = +7°C

6.18

4.65

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.40 kW

6.17 kW

COP Tj = 12°C

7.93

6.07

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

12.00 kW

12.00 kW

COP Tj = Tbiv

2.71

1.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.00 kW

12.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.71

1.93

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5416 kWh

7167 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

134 %

COP

3.35

Heating up time

0:50 h:min

Standby power input

31.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

90 %

COP

2.26

Heating up time

0:50 h:min

Standby power input

44.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

114 %

COP

2.86

Heating up time

0:50 h:min

Standby power input

34.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

WH-ADC0912K9E8AN / WH-UXZ12KE8
Configure model
Model name
WH-ADC0912K9E8AN / WH-UXZ12KE8
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.10 kW

12.10 kW

El input

2.50 kW

3.98 kW

COP

4.84

3.04

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.99 kW

Cooling capacity

10.70

EER

2.68

EN 14825

+7°C/+12°C

Pdesignc

10.00 kW

SEER

4.44

Pdc Tj = 35°C

10.00 kW

EER Tj = 35°C

2.87

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

7.37 kW

EER Tj = 30°C

3.96

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

4.74 kW

EER Tj = 25°C

4.86

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

2.11 kW

EER Tj = 20°C

5.68

Cdc Tj = 20 °C

1.000

Poff

10 W

PTO

0 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

789 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

171 %

Prated

9.00 kW

9.00 kW

SCOP

6.47

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.67

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.79 kW

5.91 kW

COP Tj = +7°C

5.88

3.75

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.28 kW

5.97 kW

COP Tj = 12°C

7.85

5.50

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.67

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.67

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1859 kWh

2772 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

127 %

Prated

11.00 kW

11.00 kW

SCOP

4.31

3.26

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.66 kW

6.66 kW

COP Tj = -7°C

3.37

2.64

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

4.75 kW

4.47 kW

COP Tj = +2°C

5.32

3.93

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.47 kW

5.25 kW

COP Tj = +7°C

6.69

5.04

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.32 kW

6.16 kW

COP Tj = 12°C

8.14

6.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.97 kW

8.97 kW

COP Tj = Tbiv

2.70

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.98 kW

8.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.02 kW

3.00 kW

Annual energy consumption Qhe

6289 kWh

8327 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.97

8.97

COP Tj = -15°C (if TOL<-20°C)

2.70

2.09

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

135 %

Prated

12.00 kW

12.00 kW

SCOP

4.58

3.46

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.62 kW

10.64 kW

COP Tj = -7°C

2.51

2.23

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

6.46 kW

6.49 kW

COP Tj = +2°C

4.53

3.24

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

5.50 kW

5.22 kW

COP Tj = +7°C

6.18

4.65

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.40 kW

6.17 kW

COP Tj = 12°C

7.93

6.07

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

12.00 kW

12.00 kW

COP Tj = Tbiv

2.71

1.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.00 kW

12.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.71

1.93

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5416 kWh

7167 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

134 %

COP

3.35

Heating up time

0:50 h:min

Standby power input

31.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

90 %

COP

2.26

Heating up time

0:50 h:min

Standby power input

44.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

114 %

COP

2.86

Heating up time

0:50 h:min

Standby power input

34.0 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

244 l

WH-SXC09K3E5 / WH-UXZ09KE5
Configure model
Model name
WH-SXC09K3E5 / WH-UXZ09KE5
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

9.00 kW

El input

1.79 kW

2.93 kW

COP

5.03

3.07

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.83 kW

Cooling capacity

8.80

EER

3.11

EN 14825

+7°C/+12°C

Pdesignc

8.00 kW

SEER

4.12

Pdc Tj = 35°C

8.00 kW

EER Tj = 35°C

3.19

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

5.89 kW

EER Tj = 30°C

3.91

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

3.79 kW

EER Tj = 25°C

4.25

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

1.68 kW

EER Tj = 20°C

5.13

Cdc Tj = 20 °C

1.000

Poff

10 W

PTO

0 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

679 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

171 %

Prated

9.00 kW

9.00 kW

SCOP

6.47

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.67

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.79 kW

5.91 kW

COP Tj = +7°C

5.88

3.75

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.28 kW

5.97 kW

COP Tj = 12°C

7.85

5.50

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.67

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.67

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1859 kWh

2772 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

127 %

Prated

11.00 kW

11.00 kW

SCOP

4.31

3.26

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.66 kW

6.66 kW

COP Tj = -7°C

3.37

2.64

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

4.75 kW

4.47 kW

COP Tj = +2°C

5.32

3.93

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.47 kW

5.25 kW

COP Tj = +7°C

6.69

5.04

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.32 kW

6.16 kW

COP Tj = 12°C

8.14

6.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.97 kW

8.97 kW

COP Tj = Tbiv

2.70

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.98 kW

8.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.02 kW

3.00 kW

Annual energy consumption Qhe

6289 kWh

8327 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.97

8.97

COP Tj = -15°C (if TOL<-20°C)

2.70

2.09

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

140 %

Prated

9.00 kW

9.00 kW

SCOP

4.96

3.57

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.96 kW

7.96 kW

COP Tj = -7°C

3.04

2.33

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.85 kW

4.85 kW

COP Tj = +2°C

4.93

3.46

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.37 kW

5.09 kW

COP Tj = +7°C

6.26

4.48

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.33 kW

6.09 kW

COP Tj = 12°C

8.19

6.02

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

2.90

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3747 kWh

5208 kWh

WH-SXC09K6E5 / WH-UXZ09KE5
Configure model
Model name
WH-SXC09K6E5 / WH-UXZ09KE5
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

9.00 kW

El input

1.79 kW

2.93 kW

COP

5.03

3.07

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.83 kW

Cooling capacity

8.80

EER

3.11

EN 14825

+7°C/+12°C

Pdesignc

8.00 kW

SEER

4.12

Pdc Tj = 35°C

8.00 kW

EER Tj = 35°C

3.19

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

5.89 kW

EER Tj = 30°C

3.91

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

3.79 kW

EER Tj = 25°C

4.25

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

1.68 kW

EER Tj = 20°C

5.13

Cdc Tj = 20 °C

1.000

Poff

10 W

PTO

0 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

679 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

171 %

Prated

9.00 kW

9.00 kW

SCOP

6.47

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.67

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.79 kW

5.91 kW

COP Tj = +7°C

5.88

3.75

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.28 kW

5.97 kW

COP Tj = 12°C

7.85

5.50

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.67

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.67

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1859 kWh

2772 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

127 %

Prated

11.00 kW

11.00 kW

SCOP

4.31

3.26

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.66 kW

6.66 kW

COP Tj = -7°C

3.37

2.64

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

4.75 kW

4.47 kW

COP Tj = +2°C

5.32

3.93

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.47 kW

5.25 kW

COP Tj = +7°C

6.69

5.04

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.32 kW

6.16 kW

COP Tj = 12°C

8.14

6.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.97 kW

8.97 kW

COP Tj = Tbiv

2.70

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.98 kW

8.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.02 kW

3.00 kW

Annual energy consumption Qhe

6289 kWh

8327 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.97

8.97

COP Tj = -15°C (if TOL<-20°C)

2.70

2.09

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

140 %

Prated

9.00 kW

9.00 kW

SCOP

4.96

3.57

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.96 kW

7.96 kW

COP Tj = -7°C

3.04

2.33

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.85 kW

4.85 kW

COP Tj = +2°C

4.93

3.46

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.37 kW

5.09 kW

COP Tj = +7°C

6.26

4.48

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.33 kW

6.09 kW

COP Tj = 12°C

8.19

6.02

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

2.90

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3747 kWh

5208 kWh

WH-SXC09K3E8 / WH-UXZ09KE8
Configure model
Model name
WH-SXC09K3E8 / WH-UXZ09KE8
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

9.00 kW

El input

1.79 kW

2.93 kW

COP

5.03

3.07

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.83 kW

Cooling capacity

8.80

EER

3.11

EN 14825

+7°C/+12°C

Pdesignc

8.00 kW

SEER

4.12

Pdc Tj = 35°C

8.00 kW

EER Tj = 35°C

3.19

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

5.89 kW

EER Tj = 30°C

3.91

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

3.79 kW

EER Tj = 25°C

4.25

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

1.68 kW

EER Tj = 20°C

5.13

Cdc Tj = 20 °C

1.000

Poff

10 W

PTO

0 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

679 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

171 %

Prated

9.00 kW

9.00 kW

SCOP

6.47

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.67

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.79 kW

5.91 kW

COP Tj = +7°C

5.88

3.75

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.28 kW

5.97 kW

COP Tj = 12°C

7.85

5.50

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.67

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.67

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1859 kWh

2772 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

127 %

Prated

11.00 kW

11.00 kW

SCOP

4.31

3.26

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.66 kW

6.66 kW

COP Tj = -7°C

3.37

2.64

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

4.75 kW

4.47 kW

COP Tj = +2°C

5.32

3.93

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.47 kW

5.25 kW

COP Tj = +7°C

6.69

5.04

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.32 kW

6.16 kW

COP Tj = 12°C

8.14

6.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.97 kW

8.97 kW

COP Tj = Tbiv

2.70

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.98 kW

8.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.02 kW

3.00 kW

Annual energy consumption Qhe

6289 kWh

8327 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.97

8.97

COP Tj = -15°C (if TOL<-20°C)

2.70

2.09

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

140 %

Prated

9.00 kW

9.00 kW

SCOP

4.96

3.57

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.96 kW

7.96 kW

COP Tj = -7°C

3.04

2.33

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.85 kW

4.85 kW

COP Tj = +2°C

4.93

3.46

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.37 kW

5.09 kW

COP Tj = +7°C

6.26

4.48

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.33 kW

6.09 kW

COP Tj = 12°C

8.19

6.02

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

2.90

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3747 kWh

5208 kWh

WH-SXC09K9E8 / WH-UXZ09KE8
Configure model
Model name
WH-SXC09K9E8 / WH-UXZ09KE8
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

9.00 kW

El input

1.79 kW

2.93 kW

COP

5.03

3.07

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.83 kW

Cooling capacity

8.80

EER

3.11

EN 14825

+7°C/+12°C

Pdesignc

8.00 kW

SEER

4.12

Pdc Tj = 35°C

8.00 kW

EER Tj = 35°C

3.19

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

5.89 kW

EER Tj = 30°C

3.91

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

3.79 kW

EER Tj = 25°C

4.25

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

1.68 kW

EER Tj = 20°C

5.13

Cdc Tj = 20 °C

1.000

Poff

10 W

PTO

0 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

679 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

171 %

Prated

9.00 kW

9.00 kW

SCOP

6.47

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.67

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.79 kW

5.91 kW

COP Tj = +7°C

5.88

3.75

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.28 kW

5.97 kW

COP Tj = 12°C

7.85

5.50

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.67

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.67

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1859 kWh

2772 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

127 %

Prated

11.00 kW

11.00 kW

SCOP

4.31

3.26

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.66 kW

6.66 kW

COP Tj = -7°C

3.37

2.64

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

4.75 kW

4.47 kW

COP Tj = +2°C

5.32

3.93

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.47 kW

5.25 kW

COP Tj = +7°C

6.69

5.04

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.32 kW

6.16 kW

COP Tj = 12°C

8.14

6.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.97 kW

8.97 kW

COP Tj = Tbiv

2.70

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.98 kW

8.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.02 kW

3.00 kW

Annual energy consumption Qhe

6289 kWh

8327 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.97

8.97

COP Tj = -15°C (if TOL<-20°C)

2.70

2.09

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

140 %

Prated

9.00 kW

9.00 kW

SCOP

4.96

3.57

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.96 kW

7.96 kW

COP Tj = -7°C

3.04

2.33

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.85 kW

4.85 kW

COP Tj = +2°C

4.93

3.46

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.37 kW

5.09 kW

COP Tj = +7°C

6.26

4.48

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.33 kW

6.09 kW

COP Tj = 12°C

8.19

6.02

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

2.90

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3747 kWh

5208 kWh

WH-SXC12K6E5 / WH-UXZ12KE5
Configure model
Model name
WH-SXC12K6E5 / WH-UXZ12KE5
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.10 kW

12.10 kW

El input

2.50 kW

3.98 kW

COP

4.84

3.04

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.99 kW

Cooling capacity

10.70

EER

2.68

EN 14825

+7°C/+12°C

Pdesignc

10.00 kW

SEER

4.44

Pdc Tj = 35°C

10.00 kW

EER Tj = 35°C

2.87

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

7.37 kW

EER Tj = 30°C

3.96

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

4.74 kW

EER Tj = 25°C

4.86

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

2.11 kW

EER Tj = 20°C

5.68

Cdc Tj = 20 °C

1.000

Poff

10 W

PTO

0 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

789 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

171 %

Prated

9.00 kW

9.00 kW

SCOP

6.47

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.67

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.79 kW

5.91 kW

COP Tj = +7°C

5.88

3.75

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.28 kW

5.97 kW

COP Tj = 12°C

7.85

5.50

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.67

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.67

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1859 kWh

2772 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

127 %

Prated

11.00 kW

11.00 kW

SCOP

4.31

3.26

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.66 kW

6.66 kW

COP Tj = -7°C

3.37

2.64

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

4.75 kW

4.47 kW

COP Tj = +2°C

5.32

3.93

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.47 kW

5.25 kW

COP Tj = +7°C

6.69

5.04

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.32 kW

6.16 kW

COP Tj = 12°C

8.14

6.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.97 kW

8.97 kW

COP Tj = Tbiv

2.70

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.98 kW

8.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.02 kW

3.00 kW

Annual energy consumption Qhe

6289 kWh

8327 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.97

8.97

COP Tj = -15°C (if TOL<-20°C)

2.70

2.09

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

140 %

Prated

9.00 kW

9.00 kW

SCOP

4.96

3.57

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.96 kW

7.96 kW

COP Tj = -7°C

3.04

2.33

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.85 kW

4.85 kW

COP Tj = +2°C

4.93

3.46

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.37 kW

5.09 kW

COP Tj = +7°C

6.26

4.48

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.33 kW

6.09 kW

COP Tj = 12°C

8.19

6.02

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

2.90

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3747 kWh

5208 kWh

WH-SXC12K9E8 / WH-UXZ12KE8
Configure model
Model name
WH-SXC12K9E8 / WH-UXZ12KE8
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.10 kW

12.10 kW

El input

2.50 kW

3.98 kW

COP

4.84

3.04

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.99 kW

Cooling capacity

10.70

EER

2.68

EN 14825

+7°C/+12°C

Pdesignc

10.00 kW

SEER

4.44

Pdc Tj = 35°C

10.00 kW

EER Tj = 35°C

2.87

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

7.37 kW

EER Tj = 30°C

3.96

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

4.74 kW

EER Tj = 25°C

4.86

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

2.11 kW

EER Tj = 20°C

5.68

Cdc Tj = 20 °C

1.000

Poff

10 W

PTO

0 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

789 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

171 %

Prated

9.00 kW

9.00 kW

SCOP

6.47

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.67

2.40

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.79 kW

5.91 kW

COP Tj = +7°C

5.88

3.75

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.28 kW

5.97 kW

COP Tj = 12°C

7.85

5.50

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.67

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.67

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1859 kWh

2772 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

127 %

Prated

11.00 kW

11.00 kW

SCOP

4.31

3.26

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.66 kW

6.66 kW

COP Tj = -7°C

3.37

2.64

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

4.75 kW

4.47 kW

COP Tj = +2°C

5.32

3.93

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.47 kW

5.25 kW

COP Tj = +7°C

6.69

5.04

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.32 kW

6.16 kW

COP Tj = 12°C

8.14

6.40

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.97 kW

8.97 kW

COP Tj = Tbiv

2.70

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.98 kW

8.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.02 kW

3.00 kW

Annual energy consumption Qhe

6289 kWh

8327 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.97

8.97

COP Tj = -15°C (if TOL<-20°C)

2.70

2.09

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

135 %

Prated

12.00 kW

12.00 kW

SCOP

4.58

3.46

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.62 kW

10.64 kW

COP Tj = -7°C

2.51

2.23

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

6.46 kW

6.49 kW

COP Tj = +2°C

4.53

3.24

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

5.50 kW

5.22 kW

COP Tj = +7°C

6.18

4.65

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.40 kW

6.17 kW

COP Tj = 12°C

7.93

6.07

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

12.00 kW

12.00 kW

COP Tj = Tbiv

2.71

1.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.00 kW

12.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.71

1.93

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

1 W

1 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5416 kWh

7167 kWh