1,500 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.30 kW
7.10 kW
El input
1.56 kW
2.34 kW
COP
4.68
3.03
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
139 %
Prated
5.63 kW
4.76 kW
SCOP
4.83
3.54
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.99 kW
4.21 kW
COP Tj = -7°C
3.15
2.08
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
2.98 kW
2.77 kW
COP Tj = +2°C
4.72
3.49
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.15 kW
2.56 kW
COP Tj = +7°C
6.36
4.64
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
3.18 kW
2.92 kW
COP Tj = 12°C
9.60
7.05
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
4.99 kW
4.21 kW
COP Tj = Tbiv
3.15
2.08
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.33 kW
4.57 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.80
1.67
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
60 °C
60 °C
Poff
8 W
8 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
40 W
40 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.30 kW
0.19 kW
Annual energy consumption Qhe
2413 kWh
2774 kWh