Certificate holders

Subtype

WSB 6-A-RME

Certificate Holder
Max Weishaupt GmbH
Max-Weishaupt-Str. 14
88477 Schwendi
Germany
Registration number
011-1W0681
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
WSB 6-A-RME
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,200 kg

Certification Date
25.10.2023
Testing basis
European KEYMARK Scheme for Heat Pumps Rev. 12 (as of 2023-03)
Generate PDF Export model CSV
  • Number of models 2

Models

WSB-6-A-RME-AI
Configure model
Model name
WSB-6-A-RME-AI
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.56 kW

5.10 kW

El input

0.71 kW

1.71 kW

COP

5.00

2.98

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

235 %

152 %

Prated

5.00 kW

5.00 kW

SCOP

6.02

3.87

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.92 kW

4.78 kW

COP Tj = +2°C

3.57

2.23

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

3.51 kW

3.24 kW

COP Tj = +7°C

5.69

3.31

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

2.15 kW

1.82 kW

COP Tj = 12°C

7.79

4.98

Cdh Tj = +12 °C

0.900

0.950

Pdh Tj = Tbiv

4.92 kW

4.78 kW

COP Tj = Tbiv

3.57

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.92 kW

4.78 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.57

2.23

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

60 °C

60 °C

Poff

12 W

12 W

PTO

4 W

4 W

PSB

14 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1121 kWh

1650 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

153 %

107 %

Prated

6.00 kW

6.00 kW

SCOP

3.85

2.75

Tbiv

-10 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

3.37 kW

3.50 kW

COP Tj = -7°C

3.50

2.41

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

2.20 kW

2.10 kW

COP Tj = +2°C

4.91

3.37

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

1.60 kW

1.40 kW

COP Tj = +7°C

5.72

3.91

Cdh Tj = +7 °C

0.900

1.000

Pdh Tj = 12°C

2.20 kW

1.90 kW

COP Tj = 12°C

7.79

6.48

Cdh Tj = +12 °C

0.900

0.950

Pdh Tj = Tbiv

4.60 kW

3.90 kW

COP Tj = Tbiv

3.20

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.94 kW

2.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.35

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

12 W

12 W

PTO

4 W

4 W

PSB

14 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

3795 kWh

4937 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

192 %

125 %

Prated

5.50 kW

5.00 kW

SCOP

4.87

3.20

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.94 kW

4.11 kW

COP Tj = -7°C

3.21

2.00

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.00 kW

2.62 kW

COP Tj = +2°C

4.79

3.12

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

1.92 kW

4.51 kW

COP Tj = +7°C

5.99

4.44

Cdh Tj = +7 °C

1.000

0.990

Pdh Tj = 12°C

2.19 kW

1.80 kW

COP Tj = 12°C

8.30

4.98

Cdh Tj = +12 °C

0.990

0.980

Pdh Tj = Tbiv

4.94 kW

4.11 kW

COP Tj = Tbiv

3.21

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.44 kW

3.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.93

1.48

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

12 W

11 W

PTO

4 W

4 W

PSB

14 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.06 kW

1.90 kW

Annual energy consumption Qhe

2331 kWh

3226 kWh

WSB-6-A-RMEK-AI
Configure model
Model name
WSB-6-A-RMEK-AI
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.56 kW

5.10 kW

El input

0.71 kW

1.71 kW

COP

5.00

2.98

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

235 %

152 %

Prated

5.00 kW

5.00 kW

SCOP

6.02

3.87

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.92 kW

4.78 kW

COP Tj = +2°C

3.57

2.23

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

3.51 kW

3.24 kW

COP Tj = +7°C

5.69

3.31

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

2.15 kW

1.82 kW

COP Tj = 12°C

7.79

4.98

Cdh Tj = +12 °C

0.900

0.950

Pdh Tj = Tbiv

4.92 kW

4.78 kW

COP Tj = Tbiv

3.57

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.92 kW

4.78 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.57

2.23

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

60 °C

60 °C

Poff

12 W

12 W

PTO

4 W

4 W

PSB

14 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1121 kWh

1650 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

153 %

107 %

Prated

6.00 kW

6.00 kW

SCOP

3.85

2.75

Tbiv

-10 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

3.37 kW

3.50 kW

COP Tj = -7°C

3.50

2.41

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

2.20 kW

2.10 kW

COP Tj = +2°C

4.91

3.37

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

1.60 kW

1.40 kW

COP Tj = +7°C

5.72

3.91

Cdh Tj = +7 °C

0.900

1.000

Pdh Tj = 12°C

2.20 kW

1.90 kW

COP Tj = 12°C

7.79

6.48

Cdh Tj = +12 °C

0.900

0.950

Pdh Tj = Tbiv

4.60 kW

3.90 kW

COP Tj = Tbiv

3.20

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.94 kW

2.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.35

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

12 W

12 W

PTO

4 W

4 W

PSB

14 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

3795 kWh

4937 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

192 %

125 %

Prated

5.50 kW

5.00 kW

SCOP

4.87

3.20

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.94 kW

4.11 kW

COP Tj = -7°C

3.21

2.00

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.00 kW

2.62 kW

COP Tj = +2°C

4.79

3.12

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

1.92 kW

4.51 kW

COP Tj = +7°C

5.99

4.44

Cdh Tj = +7 °C

1.000

0.990

Pdh Tj = 12°C

2.19 kW

1.80 kW

COP Tj = 12°C

8.30

4.98

Cdh Tj = +12 °C

0.990

0.980

Pdh Tj = Tbiv

4.91 kW

4.11 kW

COP Tj = Tbiv

3.21

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.44 kW

3.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.93

1.48

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

12 W

11 W

PTO

4 W

4 W

PSB

14 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.06 kW

1.90 kW

Annual energy consumption Qhe

2331 kWh

3226 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

132 %

COP

3.17

Heating up time

1:17 h:min

Standby power input

26.0 W

Reference hot water temperature

47.0 °C

Mixed water at 40°C

182 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

97 %

COP

2.34

Heating up time

1:43 h:min

Standby power input

33.0 W

Reference hot water temperature

47.0 °C

Mixed water at 40°C

182 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.81

Heating up time

1:28 h:min

Standby power input

30.0 W

Reference hot water temperature

47.0 °C

Mixed water at 40°C

183 l