Certificate holders

Subtype

Acond Grandis-R

Certificate Holder
Acond a.s.
Štěrboholská 1434/102a
102 00 Hostivař, Praha
Czech Republic
Registration number
037-0103-22 / rev. 1
Certification Body
SZU - Strojirensky zkusebni ustav (Engineering Test Institute, Public Enterprise)
Subtype title
Acond Grandis-R
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,320 kg

Certification Date
07.12.2022
Testing basis
HP Keymark scheme rules rev. no. 10
Testing laboratory
SZU Brno, CZ
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

Acond Grandis-R
Configure model
Model name
Acond Grandis-R
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.98 kW

6.94 kW

El input

1.26 kW

2.05 kW

COP

5.52

3.38

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

0 dB(A)

0 dB(A)

Sound power level outdoor

0 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

220 %

165 %

Prated

10.19 kW

9.97 kW

SCOP

5.58

4.21

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.97 kW

8.80 kW

COP Tj = -7°C

3.57

2.67

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.58 kW

5.37 kW

COP Tj = +2°C

5.42

4.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.03 kW

3.82 kW

COP Tj = +7°C

7.26

5.39

Cdh Tj = +7 °C

0.974

0.980

Pdh Tj = 12°C

4.63 kW

4.46 kW

COP Tj = 12°C

9.00

6.81

Cdh Tj = +12 °C

0.972

0.978

Pdh Tj = Tbiv

10.19 kW

9.97 kW

COP Tj = Tbiv

3.09

2.35

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.19 kW

9.97 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.09

2.35

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

14 W

14 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3770 kWh

4896 kWh

Acond Grandis-R SP
Configure model
Model name
Acond Grandis-R SP
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.98 kW

6.94 kW

El input

1.26 kW

2.05 kW

COP

5.52

3.38

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

0 dB(A)

0 dB(A)

Sound power level outdoor

0 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

220 %

165 %

Prated

10.19 kW

9.97 kW

SCOP

5.58

4.21

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.97 kW

8.80 kW

COP Tj = -7°C

3.57

2.67

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.58 kW

5.37 kW

COP Tj = +2°C

5.42

4.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.03 kW

3.82 kW

COP Tj = +7°C

7.26

5.39

Cdh Tj = +7 °C

0.974

0.980

Pdh Tj = 12°C

4.63 kW

4.46 kW

COP Tj = 12°C

9.00

6.81

Cdh Tj = +12 °C

0.972

0.978

Pdh Tj = Tbiv

10.19 kW

9.97 kW

COP Tj = Tbiv

3.09

2.35

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.19 kW

9.97 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.09

2.35

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

14 W

14 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3770 kWh

4896 kWh

Acond Grandis-PR
Configure model
Model name
Acond Grandis-PR
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.80 kW

8.10 kW

El input

1.42 kW

2.52 kW

COP

5.51

3.22

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

0 dB(A)

0 dB(A)

Sound power level outdoor

0 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

158 %

Prated

11.79 kW

12.13 kW

SCOP

4.89

4.03

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.43 kW

10.73 kW

COP Tj = -7°C

3.11

2.55

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.18 kW

6.52 kW

COP Tj = +2°C

4.43

3.81

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.08 kW

4.17 kW

COP Tj = +7°C

7.31

5.39

Cdh Tj = +7 °C

0.900

0.980

Pdh Tj = 12°C

4.64 kW

4.46 kW

COP Tj = 12°C

9.00

6.81

Cdh Tj = +12 °C

0.971

0.977

Pdh Tj = Tbiv

10.43 kW

10.73 kW

COP Tj = Tbiv

3.11

2.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.41 kW

10.94 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

14 W

14 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.38 kW

1.19 kW

Annual energy consumption Qhe

4979 kWh

4979 kWh

Acond Grandis-PR SP
Configure model
Model name
Acond Grandis-PR SP
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.80 kW

8.10 kW

El input

1.42 kW

2.52 kW

COP

5.51

3.22

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

0 dB(A)

0 dB(A)

Sound power level outdoor

0 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

158 %

Prated

11.79 kW

12.13 kW

SCOP

4.89

4.03

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.43 kW

10.73 kW

COP Tj = -7°C

3.11

2.55

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.18 kW

6.52 kW

COP Tj = +2°C

4.43

3.81

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.08 kW

4.17 kW

COP Tj = +7°C

7.31

5.39

Cdh Tj = +7 °C

0.900

0.980

Pdh Tj = 12°C

4.64 kW

4.46 kW

COP Tj = 12°C

9.00

6.81

Cdh Tj = +12 °C

0.971

0.977

Pdh Tj = Tbiv

10.43 kW

10.73 kW

COP Tj = Tbiv

3.11

2.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.41 kW

10.94 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

14 W

14 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.38 kW

1.19 kW

Annual energy consumption Qhe

4979 kWh

4979 kWh