KITA LP 26-28-32-35 R290

Certificate Holder
Templari S.p.A.
Via C. Battisti, n° 169
35031 Abano Terme (PD)
Italy
Registration number
ICIM-PDC-000218
Certification Body
ICIM S.p.A.
Subtype title
KITA LP 26-28-32-35 R290
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

3,500 kg

Certification Date
02.11.2023
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 4

Models

Unità esterna KITA-LP-26, 3Ph, vers. MONOBLOCCO R-290
Configure model
Model name
Unità esterna KITA-LP-26, 3Ph, vers. MONOBLOCCO R-290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

26.18 kW

24.73 kW

El input

5.16 kW

7.25 kW

COP

5.08

3.41

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

139 %

Prated

19.57 kW

19.01 kW

SCOP

4.70

3.54

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

11.79 kW

11.51 kW

COP Tj = -7°C

4.05

2.80

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

11.13 kW

10.74 kW

COP Tj = +2°C

5.92

4.69

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

9.95 kW

9.66 kW

COP Tj = +7°C

7.90

6.23

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

9.51 kW

9.47 kW

COP Tj = 12°C

10.33

8.93

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

15.96 kW

15.51 kW

COP Tj = Tbiv

2.94

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.11 kW

12.74 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.30

1.57

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

10261 kWh

13224 kWh

Pdh Tj = -15°C (if TOL<-20°C)

15.96

15.51

COP Tj = -15°C (if TOL<-20°C)

2.94

2.12

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

218 %

163 %

Prated

22.02 kW

21.17 kW

SCOP

5.51

4.15

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

19.48 kW

18.73 kW

COP Tj = -7°C

3.43

2.42

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

11.86 kW

11.40 kW

COP Tj = +2°C

5.48

4.16

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

9.87 kW

9.47 kW

COP Tj = +7°C

7.24

5.54

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

9.51 kW

9.24 kW

COP Tj = 12°C

10.33

8.13

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

19.48 kW

18.73 kW

COP Tj = Tbiv

3.43

2.42

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

19.08 kW

17.35 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.12

2.14

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.10 kW

3.60 kW

Annual energy consumption Qhe

8251 kWh

10546 kWh

Unità esterna KITA-LP-28, 3Ph, vers. MONOBLOCCO R-290
Configure model
Model name
Unità esterna KITA-LP-28, 3Ph, vers. MONOBLOCCO R-290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

28.11 kW

26.59 kW

El input

5.99 kW

8.44 kW

COP

4.69

3.15

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

143 %

Prated

21.05 kW

20.53 kW

SCOP

4.71

3.66

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

12.74 kW

12.43 kW

COP Tj = -7°C

4.03

3.06

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

11.13 kW

10.74 kW

COP Tj = +2°C

5.92

4.69

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

9.95 kW

9.66 kW

COP Tj = +7°C

7.74

6.22

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

9.50 kW

9.33 kW

COP Tj = 12°C

10.30

8.77

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

17.17 kW

16.75 kW

COP Tj = Tbiv

2.90

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.16 kW

13.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.27

1.55

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.50 kW

6.50 kW

Annual energy consumption Qhe

11027 kWh

13844 kWh

Pdh Tj = -15°C (if TOL<-20°C)

17.17

16.75

COP Tj = -15°C (if TOL<-20°C)

2.90

2.08

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

216 %

162 %

Prated

23.67 kW

22.80 kW

SCOP

5.46

4.13

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

20.94 kW

20.17 kW

COP Tj = -7°C

3.36

2.36

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

12.74 kW

12.28 kW

COP Tj = +2°C

5.41

4.14

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

9.87 kW

9.47 kW

COP Tj = +7°C

7.26

5.55

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

9.50 kW

9.24 kW

COP Tj = 12°C

10.30

8.12

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

20.94 kW

20.17 kW

COP Tj = Tbiv

3.36

2.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

19.35 kW

18.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.06

2.09

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.00 kW

4.00 kW

Annual energy consumption Qhe

8949 kWh

11400 kWh

Unità esterna KITA-LP-32, 3Ph, vers. MONOBLOCCO R-290
Configure model
Model name
Unità esterna KITA-LP-32, 3Ph, vers. MONOBLOCCO R-290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

32.22 kW

30.38 kW

El input

7.14 kW

10.09 kW

COP

4.51

3.01

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

141 %

Prated

24.31 kW

23.69 kW

SCOP

4.56

3.60

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

14.71 kW

14.34 kW

COP Tj = -7°C

3.87

2.99

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

11.27 kW

10.83 kW

COP Tj = +2°C

5.69

4.59

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

10.05 kW

9.73 kW

COP Tj = +7°C

7.34

6.04

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

9.60 kW

9.40 kW

COP Tj = 12°C

9.45

8.39

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

19.83 kW

19.32 kW

COP Tj = Tbiv

2.79

1.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.39 kW

16.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.19

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

7.50 kW

7.50 kW

Annual energy consumption Qhe

13136 kWh

16239 kWh

Pdh Tj = -15°C (if TOL<-20°C)

19.83

19.32

COP Tj = -15°C (if TOL<-20°C)

2.79

1.99

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

205 %

157 %

Prated

27.26 kW

26.28 kW

SCOP

5.22

4.00

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

24.12 kW

23.25 kW

COP Tj = -7°C

3.21

2.27

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

14.68 kW

14.15 kW

COP Tj = +2°C

5.14

3.99

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

9.44 kW

9.55 kW

COP Tj = +7°C

6.87

5.31

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

9.60 kW

9.30 kW

COP Tj = 12°C

9.45

7.78

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

24.12 kW

23.25 kW

COP Tj = Tbiv

3.21

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

22.33 kW

21.55 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.93

2.00

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.60 kW

4.60 kW

Annual energy consumption Qhe

10791 kWh

13575 kWh

Unità esterna KITA-LP-35, 3Ph, vers. MONOBLOCCO R-290
Configure model
Model name
Unità esterna KITA-LP-35, 3Ph, vers. MONOBLOCCO R-290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

35.00 kW

33.13 kW

El input

7.97 kW

11.42 kW

COP

4.39

2.90

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

182 %

141 %

Prated

26.53 kW

25.96 kW

SCOP

4.62

3.60

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

16.06 kW

15.71 kW

COP Tj = -7°C

3.86

2.94

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

11.24 kW

10.83 kW

COP Tj = +2°C

5.79

4.59

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

10.03 kW

9.73 kW

COP Tj = +7°C

7.49

6.40

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

9.57 kW

9.40 kW

COP Tj = 12°C

9.77

8.37

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

21.65 kW

21.18 kW

COP Tj = Tbiv

2.74

1.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17.99 kW

17.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.17

1.46

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

8.00 kW

8.00 kW

Annual energy consumption Qhe

14156 kWh

17781 kWh

Pdh Tj = -15°C (if TOL<-20°C)

21.65

21.18

COP Tj = -15°C (if TOL<-20°C)

2.74

1.93

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

205 %

158 %

Prated

29.75 kW

28.70 kW

SCOP

5.20

4.03

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

26.32 kW

25.39 kW

COP Tj = -7°C

3.16

2.20

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

16.02 kW

15.45 kW

COP Tj = +2°C

5.10

3.98

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

10.30 kW

9.93 kW

COP Tj = +7°C

6.85

5.64

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

9.57 kW

9.30 kW

COP Tj = 12°C

9.77

7.75

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

26.32 kW

25.39 kW

COP Tj = Tbiv

3.16

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

24.36 kW

23.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.87

1.95

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.00 kW

5.00 kW

Annual energy consumption Qhe

11827 kWh

14772 kWh