3,500 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
26.18 kW
24.73 kW
El input
5.16 kW
7.25 kW
COP
5.08
3.41
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
139 %
Prated
19.57 kW
19.01 kW
SCOP
4.70
3.54
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
11.79 kW
11.51 kW
COP Tj = -7°C
4.05
2.80
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
11.13 kW
10.74 kW
COP Tj = +2°C
5.92
4.69
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
9.95 kW
9.66 kW
COP Tj = +7°C
7.90
6.23
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
9.51 kW
9.47 kW
COP Tj = 12°C
10.33
8.93
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
15.96 kW
15.51 kW
COP Tj = Tbiv
2.94
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.11 kW
12.74 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.30
1.57
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
24 W
24 W
PTO
31 W
31 W
PSB
24 W
24 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
6.00 kW
6.00 kW
Annual energy consumption Qhe
10261 kWh
13224 kWh
Pdh Tj = -15°C (if TOL<-20°C)
15.96
15.51
COP Tj = -15°C (if TOL<-20°C)
2.94
2.12
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
218 %
163 %
Prated
22.02 kW
21.17 kW
SCOP
5.51
4.15
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
19.48 kW
18.73 kW
COP Tj = -7°C
3.43
2.42
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
11.86 kW
11.40 kW
COP Tj = +2°C
5.48
4.16
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
9.87 kW
9.47 kW
COP Tj = +7°C
7.24
5.54
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
9.51 kW
9.24 kW
COP Tj = 12°C
10.33
8.13
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
19.48 kW
18.73 kW
COP Tj = Tbiv
3.43
2.42
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
19.08 kW
17.35 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.12
2.14
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
24 W
24 W
PTO
31 W
31 W
PSB
24 W
24 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.10 kW
3.60 kW
Annual energy consumption Qhe
8251 kWh
10546 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
28.11 kW
26.59 kW
El input
5.99 kW
8.44 kW
COP
4.69
3.15
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
143 %
Prated
21.05 kW
20.53 kW
SCOP
4.71
3.66
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
12.74 kW
12.43 kW
COP Tj = -7°C
4.03
3.06
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
11.13 kW
10.74 kW
COP Tj = +2°C
5.92
4.69
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
9.95 kW
9.66 kW
COP Tj = +7°C
7.74
6.22
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
9.50 kW
9.33 kW
COP Tj = 12°C
10.30
8.77
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
17.17 kW
16.75 kW
COP Tj = Tbiv
2.90
2.08
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14.16 kW
13.83 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.27
1.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
24 W
24 W
PTO
31 W
31 W
PSB
24 W
24 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
6.50 kW
6.50 kW
Annual energy consumption Qhe
11027 kWh
13844 kWh
Pdh Tj = -15°C (if TOL<-20°C)
17.17
16.75
COP Tj = -15°C (if TOL<-20°C)
2.90
2.08
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
216 %
162 %
Prated
23.67 kW
22.80 kW
SCOP
5.46
4.13
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
20.94 kW
20.17 kW
COP Tj = -7°C
3.36
2.36
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
12.74 kW
12.28 kW
COP Tj = +2°C
5.41
4.14
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
9.87 kW
9.47 kW
COP Tj = +7°C
7.26
5.55
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
9.50 kW
9.24 kW
COP Tj = 12°C
10.30
8.12
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
20.94 kW
20.17 kW
COP Tj = Tbiv
3.36
2.36
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
19.35 kW
18.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.06
2.09
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
24 W
24 W
PTO
31 W
31 W
PSB
24 W
24 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.00 kW
4.00 kW
Annual energy consumption Qhe
8949 kWh
11400 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
32.22 kW
30.38 kW
El input
7.14 kW
10.09 kW
COP
4.51
3.01
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
141 %
Prated
24.31 kW
23.69 kW
SCOP
4.56
3.60
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
14.71 kW
14.34 kW
COP Tj = -7°C
3.87
2.99
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
11.27 kW
10.83 kW
COP Tj = +2°C
5.69
4.59
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
10.05 kW
9.73 kW
COP Tj = +7°C
7.34
6.04
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
9.60 kW
9.40 kW
COP Tj = 12°C
9.45
8.39
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
19.83 kW
19.32 kW
COP Tj = Tbiv
2.79
1.99
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
16.39 kW
16.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.19
1.49
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
24 W
24 W
PTO
31 W
31 W
PSB
24 W
24 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
7.50 kW
7.50 kW
Annual energy consumption Qhe
13136 kWh
16239 kWh
Pdh Tj = -15°C (if TOL<-20°C)
19.83
19.32
COP Tj = -15°C (if TOL<-20°C)
2.79
1.99
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
205 %
157 %
Prated
27.26 kW
26.28 kW
SCOP
5.22
4.00
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
24.12 kW
23.25 kW
COP Tj = -7°C
3.21
2.27
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
14.68 kW
14.15 kW
COP Tj = +2°C
5.14
3.99
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
9.44 kW
9.55 kW
COP Tj = +7°C
6.87
5.31
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
9.60 kW
9.30 kW
COP Tj = 12°C
9.45
7.78
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
24.12 kW
23.25 kW
COP Tj = Tbiv
3.21
2.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
22.33 kW
21.55 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.93
2.00
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
24 W
24 W
PTO
31 W
31 W
PSB
24 W
24 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.60 kW
4.60 kW
Annual energy consumption Qhe
10791 kWh
13575 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
35.00 kW
33.13 kW
El input
7.97 kW
11.42 kW
COP
4.39
2.90
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
141 %
Prated
26.53 kW
25.96 kW
SCOP
4.62
3.60
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
16.06 kW
15.71 kW
COP Tj = -7°C
3.86
2.94
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
11.24 kW
10.83 kW
COP Tj = +2°C
5.79
4.59
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
10.03 kW
9.73 kW
COP Tj = +7°C
7.49
6.40
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
9.57 kW
9.40 kW
COP Tj = 12°C
9.77
8.37
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
21.65 kW
21.18 kW
COP Tj = Tbiv
2.74
1.93
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
17.99 kW
17.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.17
1.46
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
24 W
24 W
PTO
31 W
31 W
PSB
24 W
24 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
8.00 kW
8.00 kW
Annual energy consumption Qhe
14156 kWh
17781 kWh
Pdh Tj = -15°C (if TOL<-20°C)
21.65
21.18
COP Tj = -15°C (if TOL<-20°C)
2.74
1.93
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
205 %
158 %
Prated
29.75 kW
28.70 kW
SCOP
5.20
4.03
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
26.32 kW
25.39 kW
COP Tj = -7°C
3.16
2.20
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
16.02 kW
15.45 kW
COP Tj = +2°C
5.10
3.98
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
10.30 kW
9.93 kW
COP Tj = +7°C
6.85
5.64
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
9.57 kW
9.30 kW
COP Tj = 12°C
9.77
7.75
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
26.32 kW
25.39 kW
COP Tj = Tbiv
3.16
2.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
24.36 kW
23.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.87
1.95
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
24 W
24 W
PTO
31 W
31 W
PSB
24 W
24 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.00 kW
5.00 kW
Annual energy consumption Qhe
11827 kWh
14772 kWh