Certificate holders

Subtype

KITA MP 18-20 R290

Certificate Holder
Templari S.p.A.
Via C. Battisti, n° 169
35031 Abano Terme (PD)
Italy
Registration number
ICIM-PDC-000223
Certification Body
ICIM S.p.A.
Subtype title
KITA MP 18-20 R290
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,800 kg

Certification Date
02.11.2023
Testing basis
V12
Generate PDF Export model CSV
  • Number of models 2

Models

Unità esterna KITA-MP-18, 3Ph, vers. MONOBLOCCO R-290
Configure model
Model name
Unità esterna KITA-MP-18, 3Ph, vers. MONOBLOCCO R-290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

18.04 kW

16.72 kW

El input

3.54 kW

4.95 kW

COP

5.09

3.38

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

144 %

Prated

13.15 kW

12.63 kW

SCOP

4.67

3.67

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.96 kW

7.64 kW

COP Tj = -7°C

4.03

3.09

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.75 kW

6.58 kW

COP Tj = +2°C

5.92

4.70

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.00 kW

5.87 kW

COP Tj = +7°C

7.57

6.29

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.96 kW

5.34 kW

COP Tj = 12°C

8.44

8.54

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.73 kW

10.30 kW

COP Tj = Tbiv

2.85

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.60 kW

8.18 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.18

1.51

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.50 kW

4.50 kW

Annual energy consumption Qhe

6947 kWh

8494 kWh

Pdh Tj = -15°C (if TOL<-20°C)

10.73

10.30

COP Tj = -15°C (if TOL<-20°C)

2.85

2.07

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

212 %

164 %

Prated

15.00 kW

14.32 kW

SCOP

5.38

4.18

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.27 kW

12.67 kW

COP Tj = -7°C

3.38

2.41

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.08 kW

7.71 kW

COP Tj = +2°C

5.38

4.15

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.96 kW

5.77 kW

COP Tj = +7°C

7.16

5.63

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.96 kW

5.52 kW

COP Tj = 12°C

8.44

8.39

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.27 kW

12.67 kW

COP Tj = Tbiv

3.38

2.41

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.23 kW

11.62 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.07

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.60 kW

2.60 kW

Annual energy consumption Qhe

5759 kWh

7081 kWh

Unità esterna KITA-MP-20, 3Ph, vers. MONOBLOCCO R-290
Configure model
Model name
Unità esterna KITA-MP-20, 3Ph, vers. MONOBLOCCO R-290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

20.00 kW

18.54 kW

El input

4.45 kW

5.98 kW

COP

4.49

3.10

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

143 %

Prated

16.35 kW

15.72 kW

SCOP

4.66

3.66

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.89 kW

9.52 kW

COP Tj = -7°C

3.88

2.99

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.75 kW

6.57 kW

COP Tj = +2°C

5.92

4.70

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.00 kW

5.87 kW

COP Tj = +7°C

7.59

6.30

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.96 kW

5.34 kW

COP Tj = 12°C

8.44

8.53

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.33 kW

12.83 kW

COP Tj = Tbiv

2.75

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.82 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.12

1.46

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.20 kW

5.20 kW

Annual energy consumption Qhe

8645 kWh

10587 kWh

Pdh Tj = -15°C (if TOL<-20°C)

13.33

12.83

COP Tj = -15°C (if TOL<-20°C)

2.75

1.98

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

207 %

162 %

Prated

18.56 kW

17.65 kW

SCOP

5.25

4.12

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

16.42 kW

15.61 kW

COP Tj = -7°C

3.23

2.27

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

9.99 kW

9.50 kW

COP Tj = +2°C

5.17

4.07

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.06 kW

5.76 kW

COP Tj = +7°C

7.07

5.63

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.96 kW

5.52 kW

COP Tj = 12°C

8.44

8.36

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

16.42 kW

15.61 kW

COP Tj = Tbiv

3.23

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.14 kW

14.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.93

2.00

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.20 kW

3.20 kW

Annual energy consumption Qhe

7306 kWh

8861 kWh