Certificate holders

Subtype

KITA HRP R290

Certificate Holder
Templari S.p.A.
Via C. Battisti, n° 169
35031 Abano Terme (PD)
Italy
Registration number
ICIM-PDC-000216
Certification Body
ICIM S.p.A.
Subtype title
KITA HRP R290
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,400 kg

Certification Date
02.11.2023
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 8

Models

Unità esterna KITA-HRP-10, 3Ph, vers. MONOBLOCCO R-290
Configure model
Model name
Unità esterna KITA-HRP-10, 3Ph, vers. MONOBLOCCO R-290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.32 kW

9.30 kW

El input

2.00 kW

2.86 kW

COP

5.16

3.25

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

213 %

150 %

Prated

8.52 kW

7.92 kW

SCOP

5.40

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.54 kW

7.01 kW

COP Tj = -7°C

3.32

2.34

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.71 kW

4.45 kW

COP Tj = +2°C

5.29

3.77

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.27 kW

4.09 kW

COP Tj = +7°C

7.63

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.31 kW

4.20 kW

COP Tj = 12°C

10.77

8.07

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.54 kW

7.01 kW

COP Tj = Tbiv

3.32

2.34

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.93 kW

6.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.00

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

1.50 kW

Annual energy consumption Qhe

3257 kWh

4282 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

178 %

131 %

Prated

7.39 kW

7.00 kW

SCOP

4.53

3.36

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.09 kW

4.82 kW

COP Tj = -7°C

3.98

2.90

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.75 kW

4.57 kW

COP Tj = +2°C

5.87

4.27

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.30 kW

4.18 kW

COP Tj = +7°C

7.42

6.06

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.31 kW

4.24 kW

COP Tj = 12°C

10.77

9.22

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.03 kW

5.71 kW

COP Tj = Tbiv

2.81

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.82 kW

4.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.18

1.55

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.50 kW

2.50 kW

Annual energy consumption Qhe

4024 kWh

5134 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.03

5.71

COP Tj = -15°C (if TOL<-20°C)

2.81

2.04

Cdh Tj = -15 °C

0.900

0.900

Unità esterna KITA-HRP-12, 3Ph, vers. MONOBLOCCO R-290
Configure model
Model name
Unità esterna KITA-HRP-12, 3Ph, vers. MONOBLOCCO R-290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.09 kW

10.95 kW

El input

2.47 kW

3.56 kW

COP

4.90

3.08

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

133 %

Prated

8.68 kW

8.28 kW

SCOP

4.57

3.40

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.19 kW

5.02 kW

COP Tj = -7°C

3.93

2.88

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.75 kW

4.57 kW

COP Tj = +2°C

5.87

4.27

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.30 kW

4.18 kW

COP Tj = +7°C

7.42

6.06

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.31 kW

4.24 kW

COP Tj = 12°C

10.78

9.22

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.08 kW

6.75 kW

COP Tj = Tbiv

2.70

1.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.68 kW

5.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.11

1.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.00 kW

3.00 kW

Annual energy consumption Qhe

4683 kWh

6005 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.08

6.75

COP Tj = -15°C (if TOL<-20°C)

2.70

1.96

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

210 %

149 %

Prated

9.97 kW

9.32 kW

SCOP

5.32

3.81

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.82 kW

8.25 kW

COP Tj = -7°C

3.16

2.22

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.35 kW

5.08 kW

COP Tj = +2°C

5.15

3.76

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.27 kW

4.09 kW

COP Tj = +7°C

7.63

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.31 kW

4.20 kW

COP Tj = 12°C

10.78

8.07

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.82 kW

8.25 kW

COP Tj = Tbiv

3.16

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.13 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.80 kW

1.80 kW

Annual energy consumption Qhe

3870 kWh

5056 kWh

Unità esterna KITA-HRP-14, 3Ph, vers. MONOBLOCCO R-290
Configure model
Model name
Unità esterna KITA-HRP-14, 3Ph, vers. MONOBLOCCO R-290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.09 kW

12.78 kW

El input

3.06 kW

4.45 kW

COP

4.61

2.87

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

133 %

Prated

10.13 kW

9.71 kW

SCOP

4.54

3.39

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.19 kW

5.90 kW

COP Tj = -7°C

3.80

2.81

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.75 kW

4.57 kW

COP Tj = +2°C

5.87

4.27

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.30 kW

4.18 kW

COP Tj = +7°C

7.42

6.06

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.31 kW

4.24 kW

COP Tj = 12°C

10.77

9.22

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.26 kW

7.92 kW

COP Tj = Tbiv

2.58

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.66 kW

6.28 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.01

1.43

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.50 kW

3.50 kW

Annual energy consumption Qhe

5495 kWh

7067 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.26

7.92

COP Tj = -15°C (if TOL<-20°C)

2.58

1.86

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

207 %

148 %

Prated

11.65 kW

10.88 kW

SCOP

5.25

3.78

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.30 kW

9.62 kW

COP Tj = -7°C

3.02

2.08

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.23 kW

5.82 kW

COP Tj = +2°C

5.02

3.71

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.27 kW

4.09 kW

COP Tj = +7°C

7.63

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.31 kW

4.20 kW

COP Tj = 12°C

10.77

8.57

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.30 kW

9.62 kW

COP Tj = Tbiv

3.02

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.48 kW

8.73 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

1.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.10 kW

2.10 kW

Annual energy consumption Qhe

4588 kWh

5946 kWh

Unità esterna KITA-HRP-16, 3Ph, vers. MONOBLOCCO R-290
Configure model
Model name
Unità esterna KITA-HRP-16, 3Ph, vers. MONOBLOCCO R-290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.93 kW

13.38 kW

El input

3.75 kW

5.05 kW

COP

4.25

2.65

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

132 %

Prated

10.63 kW

10.09 kW

SCOP

4.51

3.37

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.49 kW

6.09 kW

COP Tj = -7°C

3.73

2.79

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.94 kW

4.57 kW

COP Tj = +2°C

5.72

4.27

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.30 kW

4.18 kW

COP Tj = +7°C

7.42

6.06

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.31 kW

4.24 kW

COP Tj = 12°C

10.77

9.02

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.67 kW

8.23 kW

COP Tj = Tbiv

2.53

1.81

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.98

1.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.50 kW

3.50 kW

Annual energy consumption Qhe

5808 kWh

7374 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.67

8.23

COP Tj = -15°C (if TOL<-20°C)

2.53

1.81

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

204 %

147 %

Prated

12.47 kW

11.31 kW

SCOP

5.17

3.74

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.03 kW

10.01 kW

COP Tj = -7°C

2.95

2.03

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.73 kW

6.07 kW

COP Tj = +2°C

4.91

3.70

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.42 kW

4.09 kW

COP Tj = +7°C

7.63

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.31 kW

4.20 kW

COP Tj = 12°C

10.77

7.92

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.03 kW

10.01 kW

COP Tj = Tbiv

2.95

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.14 kW

9.17 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.67

1.81

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.20 kW

2.20 kW

Annual energy consumption Qhe

4985 kWh

6244 kWh

Unità esterna KITA-HRP-10, 1Ph, vers. MONOBLOCCO R-290
Configure model
Model name
Unità esterna KITA-HRP-10, 1Ph, vers. MONOBLOCCO R-290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.32 kW

9.30 kW

El input

2.00 kW

2.86 kW

COP

5.16

3.25

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

131 %

Prated

7.39 kW

7.00 kW

SCOP

4.53

3.36

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.09 kW

4.82 kW

COP Tj = -7°C

3.98

2.90

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.75 kW

4.57 kW

COP Tj = +2°C

5.87

4.27

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.30 kW

4.18 kW

COP Tj = +7°C

7.42

6.06

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.31 kW

4.24 kW

COP Tj = 12°C

10.77

9.22

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.03 kW

5.71 kW

COP Tj = Tbiv

2.81

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.82 kW

4.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.18

1.55

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.50 kW

2.50 kW

Annual energy consumption Qhe

4024 kWh

5134 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.03

5.71

COP Tj = -15°C (if TOL<-20°C)

2.81

2.04

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

213 %

150 %

Prated

8.52 kW

7.92 kW

SCOP

5.40

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.54 kW

7.01 kW

COP Tj = -7°C

3.32

2.34

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.71 kW

4.45 kW

COP Tj = +2°C

5.29

3.77

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.27 kW

4.09 kW

COP Tj = +7°C

7.63

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.31 kW

4.20 kW

COP Tj = 12°C

10.77

8.07

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.54 kW

7.01 kW

COP Tj = Tbiv

3.32

2.34

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.93 kW

6.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.00

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

1.50 kW

Annual energy consumption Qhe

3257 kWh

4282 kWh

Unità esterna KITA-HRP-12, 1Ph, vers. MONOBLOCCO R-290
Configure model
Model name
Unità esterna KITA-HRP-12, 1Ph, vers. MONOBLOCCO R-290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.09 kW

10.95 kW

El input

2.47 kW

3.56 kW

COP

4.90

3.08

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

133 %

Prated

8.68 kW

8.28 kW

SCOP

4.57

3.40

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.19 kW

5.02 kW

COP Tj = -7°C

3.93

2.88

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.75 kW

4.57 kW

COP Tj = +2°C

5.87

4.27

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.30 kW

4.18 kW

COP Tj = +7°C

7.42

6.06

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.31 kW

4.24 kW

COP Tj = 12°C

10.78

9.22

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.08 kW

6.75 kW

COP Tj = Tbiv

2.70

1.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.68 kW

5.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.11

1.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.00 kW

3.00 kW

Annual energy consumption Qhe

4683 kWh

6005 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.08

6.75

COP Tj = -15°C (if TOL<-20°C)

2.70

1.96

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

210 %

149 %

Prated

9.97 kW

9.32 kW

SCOP

5.32

3.81

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.82 kW

8.25 kW

COP Tj = -7°C

3.16

2.22

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.35 kW

5.08 kW

COP Tj = +2°C

5.15

3.76

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.27 kW

4.09 kW

COP Tj = +7°C

7.63

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.31 kW

4.20 kW

COP Tj = 12°C

10.78

8.07

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.82 kW

8.25 kW

COP Tj = Tbiv

3.16

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.13 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.80 kW

1.80 kW

Annual energy consumption Qhe

3870 kWh

5056 kWh

Unità esterna KITA-HRP-14, 1Ph, vers. MONOBLOCCO R-290
Configure model
Model name
Unità esterna KITA-HRP-14, 1Ph, vers. MONOBLOCCO R-290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.09 kW

12.78 kW

El input

3.06 kW

4.45 kW

COP

4.61

2.87

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

133 %

Prated

10.13 kW

9.71 kW

SCOP

4.54

3.39

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.19 kW

5.90 kW

COP Tj = -7°C

3.80

2.81

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.75 kW

4.57 kW

COP Tj = +2°C

5.87

4.27

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.30 kW

4.18 kW

COP Tj = +7°C

7.42

6.06

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.31 kW

4.24 kW

COP Tj = 12°C

10.77

9.22

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.26 kW

7.92 kW

COP Tj = Tbiv

2.58

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.66 kW

6.28 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.01

1.43

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.50 kW

3.50 kW

Annual energy consumption Qhe

5495 kWh

7067 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.26

7.92

COP Tj = -15°C (if TOL<-20°C)

2.58

1.86

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

207 %

148 %

Prated

11.65 kW

10.88 kW

SCOP

5.25

3.78

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.30 kW

9.62 kW

COP Tj = -7°C

3.02

2.08

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.23 kW

5.82 kW

COP Tj = +2°C

5.02

3.71

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.27 kW

4.09 kW

COP Tj = +7°C

7.63

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.31 kW

4.20 kW

COP Tj = 12°C

10.77

8.57

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.30 kW

9.62 kW

COP Tj = Tbiv

3.02

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.48 kW

8.73 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

1.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.10 kW

2.10 kW

Annual energy consumption Qhe

4588 kWh

5946 kWh

Unità esterna KITA-HRP-16, 1Ph, vers. MONOBLOCCO R-290
Configure model
Model name
Unità esterna KITA-HRP-16, 1Ph, vers. MONOBLOCCO R-290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.93 kW

13.38 kW

El input

3.75 kW

5.05 kW

COP

4.25

2.65

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

132 %

Prated

10.63 kW

10.09 kW

SCOP

4.51

3.37

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.49 kW

6.09 kW

COP Tj = -7°C

3.73

2.79

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.94 kW

4.57 kW

COP Tj = +2°C

5.72

4.27

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.30 kW

4.18 kW

COP Tj = +7°C

7.42

6.06

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.31 kW

4.24 kW

COP Tj = 12°C

10.77

9.02

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.67 kW

8.23 kW

COP Tj = Tbiv

2.53

1.81

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

6.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.98

1.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.50 kW

3.50 kW

Annual energy consumption Qhe

5808 kWh

7374 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.67

8.23

COP Tj = -15°C (if TOL<-20°C)

2.53

1.81

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

204 %

147 %

Prated

12.47 kW

11.31 kW

SCOP

5.17

3.74

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.03 kW

10.01 kW

COP Tj = -7°C

2.95

2.03

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.73 kW

6.07 kW

COP Tj = +2°C

4.91

3.70

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.42 kW

4.09 kW

COP Tj = +7°C

7.63

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.31 kW

4.20 kW

COP Tj = 12°C

10.77

7.92

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.03 kW

10.01 kW

COP Tj = Tbiv

2.95

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.14 kW

9.17 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.67

1.81

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.20 kW

2.20 kW

Annual energy consumption Qhe

4985 kWh

6244 kWh