Certificate holders

Subtype

HPM-Nd2 series 8kW 10kW

Certificate Holder
Qingdao Economic & Technology Development Zone Haier Water Heater Co., Ltd.
Haier Industry Park Qingdao Economic & Technology District
Shandong
China
Registration number
011-1W0699
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
HPM-Nd2 series 8kW 10kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,300 kg

Certification Date
06.10.2023
Testing basis
HP KEYMARK certification scheme rules V12
Generate PDF Export model CSV
  • Number of models 4

Models

HPM08-Nd2
Configure model
Model name
HPM08-Nd2
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

8.00 kW

El input

1.62 kW

2.42 kW

COP

4.95

3.30

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.50 kW

1.63 kW

Cooling capacity

8.00

8.00

EER

3.20

4.90

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.00 kW

8.00 kW

SEER

4.50

6.30

Pdc Tj = 35°C

8.09 kW

8.14 kW

EER Tj = 35°C

3.21

4.98

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

5.91 kW

6.00 kW

EER Tj = 30°C

4.13

6.25

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

3.83 kW

3.95 kW

EER Tj = 25°C

5.97

8.76

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

3.34 kW

4.11 kW

EER Tj = 20°C

7.60

10.60

Cdc Tj = 20 °C

0.900

0.900

Poff

9 W

9 W

PTO

40 W

40 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

1056 kWh

770 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

151 %

Prated

8.00 kW

8.00 kW

SCOP

4.90

3.85

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.07 kW

7.16 kW

COP Tj = -7°C

3.36

2.64

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.57 kW

4.52 kW

COP Tj = +2°C

4.90

3.79

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.07 kW

2.92 kW

COP Tj = +7°C

6.12

4.74

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.64 kW

3.50 kW

COP Tj = 12°C

7.98

6.40

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.11 kW

8.15 kW

COP Tj = Tbiv

2.88

2.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.11 kW

8.15 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.36

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

9 W

9 W

PTO

40 W

40 W

PSB

9 W

9 W

PCK

22 W

22 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3388 kWh

4365 kWh

HPM10-Nd2
Configure model
Model name
HPM10-Nd2
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.00 kW

10.00 kW

El input

2.08 kW

3.03 kW

COP

4.80

3.30

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

3.33 kW

2.15 kW

Cooling capacity

10.00

10.00

EER

3.00

4.65

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

10.00 kW

10.00 kW

SEER

4.50

6.50

Pdc Tj = 35°C

10.07 kW

10.05 kW

EER Tj = 35°C

3.06

4.69

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

7.38 kW

7.49 kW

EER Tj = 30°C

4.01

6.11

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

4.97 kW

4.88 kW

EER Tj = 25°C

5.50

8.31

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

3.34 kW

4.11 kW

EER Tj = 20°C

7.60

10.60

Cdc Tj = 20 °C

0.900

0.900

Poff

9 W

9 W

PTO

40 W

40 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

1306 kWh

927 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

151 %

Prated

10.00 kW

10.00 kW

SCOP

4.90

3.85

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.05 kW

8.98 kW

COP Tj = -7°C

3.29

2.59

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.44 kW

5.55 kW

COP Tj = +2°C

4.81

3.83

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.54 kW

3.54 kW

COP Tj = +7°C

6.43

4.92

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.66 kW

3.50 kW

COP Tj = 12°C

8.21

6.45

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.13 kW

10.15 kW

COP Tj = Tbiv

2.72

2.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.13 kW

10.15 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

2.23

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

9 W

9 W

PTO

40 W

40 W

PSB

9 W

9 W

PCK

22 W

22 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4217 kWh

5361 kWh

HPM08-Nd2(GN)
Configure model
Model name
HPM08-Nd2(GN)
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

8.00 kW

El input

1.62 kW

2.42 kW

COP

4.95

3.30

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.50 kW

1.63 kW

Cooling capacity

8.00

8.00

EER

3.20

4.90

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.00 kW

8.00 kW

SEER

4.50

6.30

Pdc Tj = 35°C

8.09 kW

8.14 kW

EER Tj = 35°C

3.21

4.98

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

5.91 kW

6.00 kW

EER Tj = 30°C

4.13

6.25

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

3.83 kW

3.95 kW

EER Tj = 25°C

5.97

8.76

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

3.34 kW

4.11 kW

EER Tj = 20°C

7.60

10.60

Cdc Tj = 20 °C

0.900

0.900

Poff

9 W

9 W

PTO

40 W

40 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

1056 kWh

770 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

151 %

Prated

8.00 kW

8.00 kW

SCOP

4.90

3.85

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.07 kW

7.16 kW

COP Tj = -7°C

3.36

2.64

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.57 kW

4.52 kW

COP Tj = +2°C

4.90

3.79

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.07 kW

2.92 kW

COP Tj = +7°C

6.12

4.74

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.64 kW

3.50 kW

COP Tj = 12°C

7.98

6.40

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.11 kW

8.15 kW

COP Tj = Tbiv

2.88

2.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.11 kW

8.15 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.36

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

9 W

9 W

PTO

40 W

40 W

PSB

9 W

9 W

PCK

22 W

22 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3388 kWh

4365 kWh

HPM10-Nd2(GN)
Configure model
Model name
HPM10-Nd2(GN)
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.00 kW

10.00 kW

El input

2.08 kW

3.03 kW

COP

4.80

3.30

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

3.33 kW

2.15 kW

Cooling capacity

10.00

10.00

EER

3.00

4.65

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

10.00 kW

10.00 kW

SEER

4.50

6.50

Pdc Tj = 35°C

10.07 kW

10.05 kW

EER Tj = 35°C

3.06

4.69

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

7.38 kW

7.49 kW

EER Tj = 30°C

4.01

6.11

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

4.97 kW

4.88 kW

EER Tj = 25°C

5.50

8.31

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

3.34 kW

4.11 kW

EER Tj = 20°C

7.60

10.60

Cdc Tj = 20 °C

0.900

0.900

Poff

9 W

9 W

PTO

40 W

40 W

PSB

9 W

9 W

PCK

0 W

0 W

Annual energy consumption Qce

1306 kWh

927 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

151 %

Prated

10.00 kW

10.00 kW

SCOP

4.90

3.85

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.05 kW

8.98 kW

COP Tj = -7°C

3.29

2.59

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.44 kW

5.55 kW

COP Tj = +2°C

4.81

3.83

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.54 kW

3.54 kW

COP Tj = +7°C

6.43

4.92

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.66 kW

3.50 kW

COP Tj = 12°C

8.21

6.45

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.13 kW

10.15 kW

COP Tj = Tbiv

2.72

2.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.13 kW

10.15 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

2.23

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

9 W

9 W

PTO

40 W

40 W

PSB

9 W

9 W

PCK

22 W

22 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4217 kWh

5361 kWh