2,500 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.03 kW
13.78 kW
El input
2.87 kW
4.75 kW
COP
4.89
2.90
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
72 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
134 %
Prated
13.91 kW
12.32 kW
SCOP
4.32
3.42
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
12.31 kW
10.90 kW
COP Tj = -7°C
3.10
2.22
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.41 kW
6.86 kW
COP Tj = +2°C
4.27
3.26
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
6.03 kW
4.64 kW
COP Tj = +7°C
5.31
4.59
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
7.15 kW
5.92 kW
COP Tj = 12°C
8.89
6.66
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.31 kW
10.90 kW
COP Tj = Tbiv
3.10
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.29 kW
10.35 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.25
1.72
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.63 kW
1.98 kW
Annual energy consumption Qhe
6659 kWh
7437 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.01 kW
15.52 kW
El input
3.61 kW
5.28 kW
COP
4.44
2.94
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
65 dB(A)
72 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
134 %
Prated
13.90 kW
12.32 kW
SCOP
4.33
3.43
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
12.30 kW
10.90 kW
COP Tj = -7°C
3.10
2.22
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.40 kW
6.85 kW
COP Tj = +2°C
4.29
3.27
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
6.02 kW
4.64 kW
COP Tj = +7°C
5.34
4.60
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
7.14 kW
5.91 kW
COP Tj = 12°C
8.96
6.67
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.30 kW
10.90 kW
COP Tj = Tbiv
3.10
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.28 kW
10.34 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.26
1.72
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.62 kW
1.98 kW
Annual energy consumption Qhe
6630 kWh
7429 kWh