1,800 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.44 kW
10.17 kW
El input
2.17 kW
3.56 kW
COP
4.84
2.86
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
63 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
129 %
Prated
9.79 kW
10.86 kW
SCOP
4.95
3.29
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
8.66 kW
9.61 kW
COP Tj = -7°C
2.96
2.01
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.36 kW
5.98 kW
COP Tj = +2°C
4.67
3.15
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.72 kW
4.29 kW
COP Tj = +7°C
6.83
4.56
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.72 kW
5.58 kW
COP Tj = 12°C
11.57
7.76
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.66 kW
9.61 kW
COP Tj = Tbiv
2.96
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.54 kW
5.13 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.65
1.75
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.25 kW
5.73 kW
Annual energy consumption Qhe
4084 kWh
6809 kWh