Certificate holders

Subtype

Monobloc Air-to Water Heat Pump System- R32- W142+ W162

Certificate Holder
Qingdao Haier Air Conditioner Electric Co., Ltd.
Haier Development Zone Industrial Park, Economic Development Zone, Qingdao City,
Shandong Province
China
Registration number
041-K073-10
Certification Body
BRE Global Limited
Subtype title
Monobloc Air-to Water Heat Pump System- R32- W142+ W162
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,500 kg

Certification Date
06.11.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 12
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

AW142MXCHA
Configure model
Model name
AW142MXCHA
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.04 kW

13.89 kW

El input

2.87 kW

4.96 kW

COP

4.89

2.80

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

69 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

134 %

Prated

14.09 kW

13.13 kW

SCOP

4.45

3.44

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

12.47 kW

11.61 kW

COP Tj = -7°C

2.87

2.18

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.50 kW

6.71 kW

COP Tj = +2°C

4.15

3.33

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.96 kW

5.74 kW

COP Tj = +7°C

6.64

5.16

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.66 kW

7.67 kW

COP Tj = 12°C

8.63

7.66

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.47 kW

11.61 kW

COP Tj = Tbiv

2.87

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.07 kW

12.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

18 W

18 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.02 kW

0.70 kW

Annual energy consumption Qhe

6537 kWh

7892 kWh

AW162MXCHA
Configure model
Model name
AW162MXCHA
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.77 kW

15.04 kW

El input

3.57 kW

5.33 kW

COP

4.42

2.82

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

69 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

134 %

Prated

14.09 kW

13.12 kW

SCOP

4.47

3.42

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

12.46 kW

11.61 kW

COP Tj = -7°C

2.87

2.18

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.50 kW

6.70 kW

COP Tj = +2°C

4.17

3.31

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.95 kW

5.73 kW

COP Tj = +7°C

6.69

5.17

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.65 kW

7.66 kW

COP Tj = 12°C

8.70

7.67

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.46 kW

11.61 kW

COP Tj = Tbiv

2.87

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.07 kW

12.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

18 W

18 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.02 kW

0.70 kW

Annual energy consumption Qhe

6508 kWh

7922 kWh