1,800 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
11.26 kW
11.05 kW
El input
2.28 kW
3.85 kW
COP
4.94
2.87
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
63 dB(A)
70 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
133 %
Prated
10.80 kW
9.73 kW
SCOP
4.63
3.39
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
9.55 kW
8.61 kW
COP Tj = -7°C
3.14
1.94
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.85 kW
6.32 kW
COP Tj = +2°C
4.51
3.44
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.92 kW
4.50 kW
COP Tj = +7°C
5.86
4.63
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.84 kW
5.87 kW
COP Tj = 12°C
8.77
8.09
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
9.55 kW
8.61 kW
COP Tj = Tbiv
3.14
1.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.30 kW
5.13 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.23
1.75
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
18 W
18 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.50 kW
4.60 kW
Annual energy consumption Qhe
4823 kWh
5930 kWh