Certificate holders

Subtype

Johnson ASHP AT150

Certificate Holder
EAS Electric Smart Technology SL
Camino La Sierra, s/n Parcela 11 Redován
03370 Alicante
Spain
Registration number
041-K066-16
Certification Body
BRE
Subtype title
Johnson ASHP AT150
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,050 kg

Certification Date
06.10.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 12
Testing laboratory
TÜV SÜD Certification and Testing Co., Ltd. Guangzhou Branch, CN
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

Johnson AURUM-AT150M
Configure model
Model name
Johnson AURUM-AT150M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.38 kW

12.40 kW

El input

2.66 kW

4.18 kW

COP

4.66

2.97

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

67 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

148 %

Prated

9.90 kW

10.22 kW

SCOP

4.77

3.77

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.76 kW

9.04 kW

COP Tj = -7°C

3.15

2.28

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.50 kW

5.51 kW

COP Tj = +2°C

4.57

3.64

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.75 kW

3.57 kW

COP Tj = +7°C

6.20

5.11

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.27 kW

4.09 kW

COP Tj = 12°C

9.06

7.09

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.76 kW

9.04 kW

COP Tj = Tbiv

3.15

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.94 kW

9.99 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.74

2.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

64 °C

64 °C

Poff

13 W

13 W

PTO

38 W

38 W

PSB

13 W

13 W

PCK

83 W

83 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.23 kW

Annual energy consumption Qhe

4286 kWh