Certificate holders

Subtype

Johnson ASHP 160

Certificate Holder
EAS Electric Smart Technology SL.
Poligono Industrial San Carlos Parcela 13 03370 Redovan
Alicante
Spain
Registration number
041-K066-12
Certification Body
BRE Global Limited
Subtype title
Johnson ASHP 160
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,800 kg

Certification Date
06.10.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 12
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

Johnson AURUM160M
Configure model
Model name
Johnson AURUM160M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.52 kW

14.83 kW

El input

3.17 kW

4.88 kW

COP

4.57

3.04

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

126 %

Prated

10.49 kW

9.96 kW

SCOP

4.51

3.22

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.28 kW

8.81 kW

COP Tj = -7°C

3.21

2.16

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.88 kW

5.38 kW

COP Tj = +2°C

4.36

3.15

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.45 kW

5.87 kW

COP Tj = +7°C

6.00

4.30

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

6.22 kW

6.75 kW

COP Tj = 12°C

8.03

6.07

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

9.28 kW

8.81 kW

COP Tj = Tbiv

3.21

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.00 kW

9.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.99

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

51 °C

51 °C

Poff

12 W

12 W

PTO

15 W

15 W

PSB

12 W

12 W

PCK

42 W

42 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.49 kW

0.10 kW

Annual energy consumption Qhe

4808 kWh

6390 kWh