Certificate holders

Subtype

M thermal A series 22 26 kW

Certificate Holder
EAS Electric Smart Technology SL
Camino La Sierra, s/n Parcela 11 Redován
03370 Alicante
Spain
Registration number
041-K066-09
Certification Body
BRE
Subtype title
M thermal A series 22 26 kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

5,000 kg

Certification Date
06.10.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 12
Testing laboratory
TÜV SÜD Certification and Testing Co., Ltd. Guangzhou Branch, CN
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

ETH220VMA
Configure model
Model name
ETH220VMA
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

22.30 kW

22.10 kW

El input

5.13 kW

8.33 kW

COP

4.35

2.65

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

73 dB(A)

73 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

234 %

161 %

Prated

21.90 kW

22.01 kW

SCOP

5.85

4.09

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

21.81 kW

22.01 kW

COP Tj = +2°C

3.31

2.12

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

14.08 kW

14.15 kW

COP Tj = +7°C

5.20

3.50

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

6.44 kW

6.38 kW

COP Tj = 12°C

7.50

5.34

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

14.08 kW

14.15 kW

COP Tj = Tbiv

5.20

3.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

21.81 kW

22.01 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.31

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.09 kW

0.00 kW

Annual energy consumption Qhe

4945 kWh

7180 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

73 dB(A)

73 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

146 %

102 %

Prated

21.40 kW

22.36 kW

SCOP

3.72

2.62

Tbiv

-15 °C

-7 °C

TOL

-22 °C

-15 °C

Pdh Tj = -7°C

13.30 kW

13.53 kW

COP Tj = -7°C

3.12

2.07

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

8.25 kW

8.61 kW

COP Tj = +2°C

4.42

3.70

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

5.45 kW

5.21 kW

COP Tj = +7°C

5.87

4.49

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.98 kW

3.74 kW

COP Tj = 12°C

7.19

5.76

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

17.46 kW

13.53 kW

COP Tj = Tbiv

2.36

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.27 kW

13.78 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.69

1.24

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

8.13 kW

22.36 kW

Annual energy consumption Qhe

14179 kWh

21067 kWh

Pdh Tj = -15°C (if TOL<-20°C)

17.46

13.78

COP Tj = -15°C (if TOL<-20°C)

2.36

1.24

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

73 dB(A)

73 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

126 %

Prated

22.31 kW

22.43 kW

SCOP

4.53

3.22

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

19.72 kW

19.82 kW

COP Tj = -7°C

2.74

1.74

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

12.03 kW

11.89 kW

COP Tj = +2°C

4.41

3.32

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

8.00 kW

7.97 kW

COP Tj = +7°C

6.29

4.66

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.79 kW

3.60 kW

COP Tj = 12°C

7.14

5.32

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

19.72 kW

19.82 kW

COP Tj = Tbiv

2.74

1.74

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

20.33 kW

13.81 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.35

1.08

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.97 kW

8.60 kW

Annual energy consumption Qhe

10180 kWh

14390 kWh

ETH260VMA
Configure model
Model name
ETH260VMA
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

26.30 kW

26.06 kW

El input

6.50 kW

10.72 kW

COP

4.05

2.43

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

75 dB(A)

75 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

231 %

168 %

Prated

26.08 kW

26.22 kW

SCOP

5.85

4.26

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

25.50 kW

26.22 kW

COP Tj = +2°C

3.00

1.99

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

16.77 kW

16.86 kW

COP Tj = +7°C

5.02

3.47

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.65 kW

7.58 kW

COP Tj = 12°C

7.78

5.94

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

16.77 kW

16.86 kW

COP Tj = Tbiv

5.02

3.47

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

25.50 kW

26.22 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.00

1.99

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.58 kW

0.00 kW

Annual energy consumption Qhe

5959 kWh

8218 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

75 dB(A)

75 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

143 %

101 %

Prated

25.75 kW

26.27 kW

SCOP

3.64

2.59

Tbiv

-12 °C

-7 °C

TOL

-22 °C

-15 °C

Pdh Tj = -7°C

15.91 kW

15.90 kW

COP Tj = -7°C

3.10

2.10

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

10.10 kW

10.17 kW

COP Tj = +2°C

4.45

3.58

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

6.30 kW

6.52 kW

COP Tj = +7°C

6.06

4.99

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.03 kW

3.63 kW

COP Tj = 12°C

7.13

5.68

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

18.97 kW

15.90 kW

COP Tj = Tbiv

2.36

2.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.07 kW

13.37 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.67

1.20

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

12.68 kW

26.27 kW

Annual energy consumption Qhe

17421 kWh

24967 kWh

Pdh Tj = -15°C (if TOL<-20°C)

18.95

13.37

COP Tj = -15°C (if TOL<-20°C)

2.27

1.20

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

75 dB(A)

75 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

123 %

Prated

25.04 kW

26.15 kW

SCOP

4.50

3.14

Tbiv

-7 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

22.12 kW

20.64 kW

COP Tj = -7°C

2.57

1.69

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

13.76 kW

14.26 kW

COP Tj = +2°C

4.44

3.12

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

9.36 kW

9.29 kW

COP Tj = +7°C

6.52

4.74

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.09 kW

3.89 kW

COP Tj = 12°C

7.35

5.48

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

22.12 kW

22.11 kW

COP Tj = Tbiv

2.57

1.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

20.33 kW

13.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.35

1.08

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.68 kW

12.28 kW

Annual energy consumption Qhe

11489 kWh

17204 kWh