1,200 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.00 kW
4.00 kW
El input
0.83 kW
1.54 kW
COP
4.80
2.60
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
127 %
Prated
6.00 kW
5.50 kW
SCOP
4.73
3.25
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.40 kW
4.87 kW
COP Tj = -7°C
2.89
2.05
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.31 kW
2.97 kW
COP Tj = +2°C
4.48
3.02
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.20 kW
2.50 kW
COP Tj = +7°C
6.36
4.50
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.31 kW
2.43 kW
COP Tj = 12°C
9.57
6.89
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.40 kW
4.87 kW
COP Tj = Tbiv
2.89
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.11 kW
5.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.61
1.73
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
62 °C
62 °C
Poff
10 W
10 W
PTO
20 W
20 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.89 kW
0.50 kW
Annual energy consumption Qhe
2645 kWh
3513 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.00 kW
5.80 kW
El input
1.33 kW
2.15 kW
COP
4.50
2.70
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
127 %
Prated
6.00 kW
5.50 kW
SCOP
4.73
3.25
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.40 kW
4.87 kW
COP Tj = -7°C
2.89
2.05
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.31 kW
2.97 kW
COP Tj = +2°C
4.48
3.02
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.20 kW
2.50 kW
COP Tj = +7°C
6.36
4.50
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.31 kW
2.43 kW
COP Tj = 12°C
9.57
6.89
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.40 kW
4.87 kW
COP Tj = Tbiv
2.89
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.11 kW
5.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.61
1.73
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
62 °C
62 °C
Poff
10 W
10 W
PTO
20 W
20 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.89 kW
0.50 kW
Annual energy consumption Qhe
2645 kWh
3513 kWh