Certificate holders

Subtype

Monobloc Heat pump 8KW

Certificate Holder
Guangdong Carrier Heating, Ventilation & Air Conditioning Company Limited
No.28-5, Eastern Industrial Park, Lishui Town, Nanhai District
528244 Foshan Guangdong
China
Registration number
011-1W0692
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Monobloc Heat pump 8KW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,600 kg

Certification Date
09.10.2023
Testing basis
HP KEYMARK certification scheme rules V12
Generate PDF Export model CSV
  • Number of models 1

Models

CE-HRDL-8/BPDR4Y-H9-D01
Configure model
Model name
CE-HRDL-8/BPDR4Y-H9-D01
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

7.70 kW

El input

1.68 kW

2.70 kW

COP

4.75

2.85

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

131 %

Prated

8.09 kW

7.61 kW

SCOP

4.90

3.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.16 kW

6.73 kW

COP Tj = -7°C

3.08

2.03

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.33 kW

4.07 kW

COP Tj = +2°C

4.62

3.15

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.98 kW

3.40 kW

COP Tj = +7°C

6.91

4.92

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.06 kW

3.42 kW

COP Tj = 12°C

9.26

7.10

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.16 kW

6.73 kW

COP Tj = Tbiv

3.08

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.80 kW

6.62 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.78

1.74

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

62 °C

62 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.29 kW

0.99 kW

Annual energy consumption Qhe

3335 kWh

4590 kWh