Monobloc Heat pump 6KW

Certificate Holder
Guangdong Carrier Heating, Ventilation & Air Conditioning Company Limited
No.28-5, Eastern Industrial Park, Lishui Town, Nanhai District
528244 Foshan Guangdong
China
Registration number
011-1W0691
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Monobloc Heat pump 6KW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,100 kg

Certification Date
09.10.2023
Testing basis
HP KEYMARK certification scheme rules V12
Generate PDF Export model CSV
  • Number of models 1

Models

CE-HRDL-6/BPDR4Y-H9-D01
Configure model
Model name
CE-HRDL-6/BPDR4Y-H9-D01
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.00 kW

5.80 kW

El input

1.33 kW

2.15 kW

COP

4.50

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

127 %

Prated

6.05 kW

5.59 kW

SCOP

4.75

3.25

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.35 kW

4.94 kW

COP Tj = -7°C

2.92

1.98

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.23 kW

3.00 kW

COP Tj = +2°C

4.57

3.08

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.14 kW

2.79 kW

COP Tj = +7°C

6.47

4.68

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.27 kW

2.55 kW

COP Tj = 12°C

9.10

6.89

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.35 kW

4.94 kW

COP Tj = Tbiv

2.92

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.01 kW

4.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.58

1.67

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

62 °C

62 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.04 kW

0.79 kW

Annual energy consumption Qhe

2583 kWh

3480 kWh