Certificate holders

Subtype

Monobloc Heat pump 14/16KW

Certificate Holder
Guangdong Carrier Heating, Ventilation & Air Conditioning Company Limited
No.28-5, Eastern Industrial Park, Lishui Town, Nanhai District
528244 Foshan Guangdong
China
Registration number
011-1W0695
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Monobloc Heat pump 14/16KW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,600 kg

Certification Date
09.10.2023
Testing basis
HP KEYMARK certification scheme rules V12
Generate PDF Export model CSV
  • Number of models 4

Models

CE-HRDL-14/BPDR4Y-H9-080
Configure model
Model name
CE-HRDL-14/BPDR4Y-H9-080
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

12.00 kW

El input

2.98 kW

4.36 kW

COP

4.70

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

69 dB(A)

69 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

134 %

Prated

14.03 kW

11.99 kW

SCOP

4.94

3.42

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.41 kW

10.61 kW

COP Tj = -7°C

3.00

2.04

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.51 kW

6.57 kW

COP Tj = +2°C

4.70

3.17

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.11 kW

4.36 kW

COP Tj = +7°C

6.90

4.90

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.64 kW

4.35 kW

COP Tj = 12°C

9.50

7.72

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.41 kW

10.61 kW

COP Tj = Tbiv

3.00

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.89 kW

10.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.78

1.78

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

62 °C

62 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.14 kW

1.65 kW

Annual energy consumption Qhe

5789 kWh

7204 kWh

CE-HRDL-14/BPDSR4Y-H9-080
Configure model
Model name
CE-HRDL-14/BPDSR4Y-H9-080
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

12.00 kW

El input

2.98 kW

4.36 kW

COP

4.70

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

69 dB(A)

69 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

134 %

Prated

14.03 kW

11.99 kW

SCOP

4.94

3.42

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.41 kW

10.61 kW

COP Tj = -7°C

3.00

2.04

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.51 kW

6.57 kW

COP Tj = +2°C

4.70

3.17

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.11 kW

4.36 kW

COP Tj = +7°C

6.90

4.90

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.64 kW

4.35 kW

COP Tj = 12°C

9.50

7.72

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.41 kW

10.61 kW

COP Tj = Tbiv

3.00

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.89 kW

10.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.78

1.78

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

62 °C

62 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.14 kW

1.65 kW

Annual energy consumption Qhe

5789 kWh

7204 kWh

CE-HRDL-16/BPDR4Y-H9-080
Configure model
Model name
CE-HRDL-16/BPDR4Y-H9-080
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

13.50 kW

El input

3.44 kW

5.00 kW

COP

4.65

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

70 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

131 %

Prated

14.79 kW

13.06 kW

SCOP

4.78

3.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.08 kW

11.55 kW

COP Tj = -7°C

2.93

2.00

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.25 kW

7.13 kW

COP Tj = +2°C

4.52

3.13

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.60 kW

4.53 kW

COP Tj = +7°C

6.39

4.78

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.64 kW

4.35 kW

COP Tj = 12°C

9.50

7.72

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.08 kW

11.55 kW

COP Tj = Tbiv

2.93

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.66 kW

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

62 °C

62 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.13 kW

2.56 kW

Annual energy consumption Qhe

6392 kWh

7948 kWh

CE-HRDL-16/BPDSR4Y-H9-080
Configure model
Model name
CE-HRDL-16/BPDSR4Y-H9-080
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

13.50 kW

El input

3.44 kW

5.00 kW

COP

4.65

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

70 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

131 %

Prated

14.79 kW

13.06 kW

SCOP

4.78

3.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.08 kW

11.55 kW

COP Tj = -7°C

2.93

2.00

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.25 kW

7.13 kW

COP Tj = +2°C

4.52

3.13

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.60 kW

4.53 kW

COP Tj = +7°C

6.39

4.78

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.64 kW

4.35 kW

COP Tj = 12°C

9.50

7.72

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.08 kW

11.55 kW

COP Tj = Tbiv

2.93

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.66 kW

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

62 °C

62 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.13 kW

2.56 kW

Annual energy consumption Qhe

6392 kWh

7948 kWh