1,800 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.00 kW
9.50 kW
El input
2.22 kW
3.54 kW
COP
4.50
2.68
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
196 %
134 %
Prated
9.73 kW
9.09 kW
SCOP
4.98
3.41
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.61 kW
8.04 kW
COP Tj = -7°C
2.93
1.97
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.05 kW
4.74 kW
COP Tj = +2°C
4.70
3.25
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.67 kW
3.55 kW
COP Tj = +7°C
7.29
5.01
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.03 kW
3.96 kW
COP Tj = 12°C
10.15
7.00
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.61 kW
8.04 kW
COP Tj = Tbiv
2.93
1.97
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.24 kW
7.55 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.67
1.70
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
62 °C
62 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.49 kW
1.54 kW
Annual energy consumption Qhe
3980 kWh
5378 kWh