2,600 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
15.97 kW
14.00 kW
El input
3.80 kW
5.61 kW
COP
4.20
2.50
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
72 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
161 %
119 %
Prated
16.00 kW
13.92 kW
SCOP
4.10
3.05
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
14.15 kW
12.31 kW
COP Tj = -7°C
2.73
1.78
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
8.75 kW
7.69 kW
COP Tj = +2°C
3.86
3.08
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.78 kW
4.63 kW
COP Tj = +7°C
5.78
4.01
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.09 kW
5.25 kW
COP Tj = 12°C
6.12
6.39
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
14.15 kW
12.31 kW
COP Tj = Tbiv
2.73
1.78
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.35 kW
7.96 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.46
1.13
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
55 °C
55 °C
Poff
5 W
5 W
PTO
59 W
59 W
PSB
5 W
5 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.65 kW
5.95 kW
Annual energy consumption Qhe
8071 kWh
9441 kWh