Certificate holders

Subtype

Monobloc Air-to-Water Heat Pump System- R32- U162

Certificate Holder
Qingdao Haier Air Conditioner Electric Co., Ltd.
Haier Development Zone Industrial Park, Economic Development Zone, Qingdao City,
Shandong Province
China
Registration number
041-K073-04
Certification Body
BRE Global Limited
Subtype title
Monobloc Air-to-Water Heat Pump System- R32- U162
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,600 kg

Certification Date
06.11.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 12
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

AU162FYCRA(HW)
Configure model
Model name
AU162FYCRA(HW)
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.97 kW

14.00 kW

El input

3.80 kW

5.61 kW

COP

4.20

2.50

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

68 dB(A)

72 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

119 %

Prated

16.00 kW

13.92 kW

SCOP

4.10

3.05

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

14.15 kW

12.31 kW

COP Tj = -7°C

2.73

1.78

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.75 kW

7.69 kW

COP Tj = +2°C

3.86

3.08

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.78 kW

4.63 kW

COP Tj = +7°C

5.78

4.01

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

5.09 kW

5.25 kW

COP Tj = 12°C

6.12

6.39

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

14.15 kW

12.31 kW

COP Tj = Tbiv

2.73

1.78

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.35 kW

7.96 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.46

1.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

5 W

5 W

PTO

59 W

59 W

PSB

5 W

5 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.65 kW

5.95 kW

Annual energy consumption Qhe

8071 kWh