1,150 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.77 kW
6.96 kW
El input
1.72 kW
2.72 kW
COP
4.52
2.56
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
157 %
116 %
Prated
7.91 kW
6.91 kW
SCOP
4.00
2.98
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
7.00 kW
6.11 kW
COP Tj = -7°C
2.88
1.92
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.37 kW
3.64 kW
COP Tj = +2°C
3.86
2.90
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.90 kW
2.66 kW
COP Tj = +7°C
5.17
4.13
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.96 kW
2.07 kW
COP Tj = 12°C
6.31
5.06
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.00 kW
6.11 kW
COP Tj = Tbiv
2.88
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.88 kW
5.56 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.05
1.58
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
55 °C
55 °C
Poff
5 W
5 W
PTO
50 W
50 W
PSB
5 W
5 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.03 kW
1.34 kW
Annual energy consumption Qhe
4081 kWh
4785 kWh