1,800 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5 kW
4 kW
El input
1 kW
1.63 kW
COP
5.02
2.45
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.46 kW
1.11 kW
Cooling capacity
5.1
6
EER
3.5
5.4
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.1 kW
6 kW
SEER
3.89
5.93
Pdc Tj = 35°C
5.1 kW
6 kW
EER Tj = 35°C
3.5
5.4
Cdc Tj = 35 °C
0.99
0.987
Pdc Tj = 30°C
3.76 kW
4.42 kW
EER Tj = 30°C
3.84
5.95
Cdc Tj = 30 °C
0.985
0.98
Pdc Tj = 25°C
2.42 kW
3.3 kW
EER Tj = 25°C
4.07
6.38
Cdc Tj = 25 °C
0.975
0.971
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.57
7
Cdc Tj = 20 °C
0.973
0.97
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
787 kWh
608 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
128 %
Prated
6 kW
6 kW
SCOP
4.7
3.29
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.37 kW
5.31 kW
COP Tj = -7°C
3.38
2.27
Cdh Tj = -7 °C
0.991
0.994
Pdh Tj = +2°C
4.79 kW
4.4 kW
COP Tj = +2°C
4.77
3.2
Cdh Tj = +2 °C
0.985
0.989
Pdh Tj = +7°C
4.9 kW
4.1 kW
COP Tj = +7°C
5.61
3.99
Cdh Tj = +7 °C
0.983
0.985
Pdh Tj = 12°C
3 kW
2.7 kW
COP Tj = 12°C
6.19
5.58
Cdh Tj = +12 °C
0.969
0.969
Pdh Tj = Tbiv
6 kW
6 kW
COP Tj = Tbiv
2.74
1.99
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6 kW
6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
1.99
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
70 °C
70 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2640 kWh
3772 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
137 %
COP
3.25
Heating up time
1:55 h:min
Standby power input
42.1 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6 kW
4 kW
El input
1.2 kW
1.6 kW
COP
5.02
2.5
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.15 kW
1.62 kW
Cooling capacity
7.1
8
EER
3.3
4.95
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.1 kW
8 kW
SEER
4.13
5.74
Pdc Tj = 35°C
7.1 kW
8 kW
EER Tj = 35°C
3.3
4.95
Cdc Tj = 35 °C
0.993
0.991
Pdc Tj = 30°C
5.23 kW
5.92 kW
EER Tj = 30°C
3.85
5.7
Cdc Tj = 30 °C
0.989
0.986
Pdc Tj = 25°C
3.36 kW
3.79 kW
EER Tj = 25°C
4.55
6
Cdc Tj = 25 °C
0.98
0.976
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.69
6.75
Cdc Tj = 20 °C
0.972
0.971
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
1031 kWh
836 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
130 %
Prated
8 kW
8 kW
SCOP
4.68
3.34
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.08 kW
7.08 kW
COP Tj = -7°C
3.22
2.27
Cdh Tj = -7 °C
0.993
0.995
Pdh Tj = +2°C
4.4 kW
4.4 kW
COP Tj = +2°C
4.78
3.2
Cdh Tj = +2 °C
0.984
0.989
Pdh Tj = +7°C
5 kW
4.4 kW
COP Tj = +7°C
5.61
4.18
Cdh Tj = +7 °C
0.983
0.986
Pdh Tj = 12°C
3 kW
2.8 kW
COP Tj = 12°C
6.19
5.79
Cdh Tj = +12 °C
0.969
0.969
Pdh Tj = Tbiv
7.08 kW
7.08 kW
COP Tj = Tbiv
3.2
2.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.5 kW
7.4 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
70 °C
70 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.5 kW
0.6 kW
Annual energy consumption Qhe
3528 kWh
4952 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
137 %
COP
3.25
Heating up time
1:55 h:min
Standby power input
42.1 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6 kW
4 kW
El input
1.2 kW
1.6 kW
COP
5.02
2.5
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.15 kW
1.62 kW
Cooling capacity
7.1
8
EER
3.3
4.95
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.1 kW
8 kW
SEER
4.07
5.63
Pdc Tj = 35°C
7.1 kW
8 kW
EER Tj = 35°C
3.3
4.95
Cdc Tj = 35 °C
0.99
0.986
Pdc Tj = 30°C
5.23 kW
5.92 kW
EER Tj = 30°C
3.85
5.7
Cdc Tj = 30 °C
0.984
0.979
Pdc Tj = 25°C
3.36 kW
3.79 kW
EER Tj = 25°C
4.55
6
Cdc Tj = 25 °C
0.97
0.965
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.69
6.75
Cdc Tj = 20 °C
0.959
0.958
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Annual energy consumption Qce
1048 kWh
853 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
130 %
Prated
8 kW
8 kW
SCOP
4.67
3.33
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.08 kW
7.08 kW
COP Tj = -7°C
3.22
2.27
Cdh Tj = -7 °C
0.99
0.993
Pdh Tj = +2°C
4.4 kW
4.4 kW
COP Tj = +2°C
4.78
3.2
Cdh Tj = +2 °C
0.976
0.984
Pdh Tj = +7°C
5 kW
4.4 kW
COP Tj = +7°C
5.61
4.18
Cdh Tj = +7 °C
0.975
0.979
Pdh Tj = 12°C
3 kW
2.8 kW
COP Tj = 12°C
6.19
5.79
Cdh Tj = +12 °C
0.955
0.955
Pdh Tj = Tbiv
7.08 kW
7.08 kW
COP Tj = Tbiv
3.2
2.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.5 kW
7.4 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.995
WTOL
70 °C
70 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.5 kW
0.6 kW
Annual energy consumption Qhe
3540 kWh
4964 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
137 %
COP
3.25
Heating up time
1:55 h:min
Standby power input
42.1 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8 kW
7 kW
El input
1.59 kW
2.59 kW
COP
5.02
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
3 kW
2.22 kW
Cooling capacity
9
10
EER
3
4.5
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9 kW
10 kW
SEER
3.98
5.73
Pdc Tj = 35°C
9 kW
10 kW
EER Tj = 35°C
3
4.5
Cdc Tj = 35 °C
0.995
0.993
Pdc Tj = 30°C
6.63 kW
7.37 kW
EER Tj = 30°C
3.82
5.68
Cdc Tj = 30 °C
0.991
0.988
Pdc Tj = 25°C
4.26 kW
4.74 kW
EER Tj = 25°C
4.43
6.05
Cdc Tj = 25 °C
0.984
0.981
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.23
6.55
Cdc Tj = 20 °C
0.975
0.972
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
1357 kWh
1047 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
134 %
Prated
10 kW
10 kW
SCOP
4.6
3.42
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.8 kW
8.8 kW
COP Tj = -7°C
3.05
2.15
Cdh Tj = -7 °C
0.995
0.996
Pdh Tj = +2°C
5.4 kW
5.4 kW
COP Tj = +2°C
4.61
3.35
Cdh Tj = +2 °C
0.987
0.991
Pdh Tj = +7°C
5.2 kW
4.8 kW
COP Tj = +7°C
5.7
4.39
Cdh Tj = +7 °C
0.984
0.986
Pdh Tj = 12°C
3.2 kW
2.9 kW
COP Tj = 12°C
6.61
5.99
Cdh Tj = +12 °C
0.969
0.969
Pdh Tj = Tbiv
8.8 kW
8.8 kW
COP Tj = Tbiv
3.05
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9 kW
8.5 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.4
1.7
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
70 °C
70 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1 kW
1.5 kW
Annual energy consumption Qhe
4494 kWh
6033 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
137 %
COP
3.25
Heating up time
1:55 h:min
Standby power input
42.1 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8 kW
7 kW
El input
1.59 kW
2.59 kW
COP
5.02
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
3 kW
2.22 kW
Cooling capacity
9
10
EER
3
4.5
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9 kW
10 kW
SEER
3.93
5.64
Pdc Tj = 35°C
9 kW
10 kW
EER Tj = 35°C
3
4.5
Cdc Tj = 35 °C
0.993
0.99
Pdc Tj = 30°C
6.63 kW
7.37 kW
EER Tj = 30°C
3.82
5.68
Cdc Tj = 30 °C
0.987
0.983
Pdc Tj = 25°C
4.26 kW
4.74 kW
EER Tj = 25°C
4.43
6.05
Cdc Tj = 25 °C
0.977
0.972
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.23
6.55
Cdc Tj = 20 °C
0.963
0.959
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Annual energy consumption Qce
1372 kWh
1064 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
134 %
Prated
10 kW
10 kW
SCOP
4.59
3.42
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.8 kW
8.8 kW
COP Tj = -7°C
3.05
2.15
Cdh Tj = -7 °C
0.992
0.995
Pdh Tj = +2°C
5.4 kW
5.4 kW
COP Tj = +2°C
4.61
3.35
Cdh Tj = +2 °C
0.981
0.986
Pdh Tj = +7°C
5.2 kW
4.8 kW
COP Tj = +7°C
5.7
4.39
Cdh Tj = +7 °C
0.976
0.98
Pdh Tj = 12°C
3.2 kW
2.9 kW
COP Tj = 12°C
6.61
5.99
Cdh Tj = +12 °C
0.955
0.955
Pdh Tj = Tbiv
8.8 kW
8.8 kW
COP Tj = Tbiv
3.05
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9 kW
8.5 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.4
1.7
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.996
WTOL
70 °C
70 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1 kW
1.5 kW
Annual energy consumption Qhe
4505 kWh
6042 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
137 %
COP
3.25
Heating up time
1:55 h:min
Standby power input
42.1 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5 kW
4 kW
El input
1 kW
1.63 kW
COP
5.02
2.45
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.46 kW
1.11 kW
Cooling capacity
5.1
6
EER
3.5
5.4
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.1 kW
6 kW
SEER
3.89
5.93
Pdc Tj = 35°C
5.1 kW
6 kW
EER Tj = 35°C
3.5
5.4
Cdc Tj = 35 °C
0.99
0.987
Pdc Tj = 30°C
3.76 kW
4.42 kW
EER Tj = 30°C
3.84
5.95
Cdc Tj = 30 °C
0.985
0.98
Pdc Tj = 25°C
2.42 kW
3.3 kW
EER Tj = 25°C
4.07
6.38
Cdc Tj = 25 °C
0.975
0.971
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.57
7
Cdc Tj = 20 °C
0.973
0.97
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
787 kWh
608 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
128 %
Prated
6 kW
6 kW
SCOP
4.7
3.29
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.37 kW
5.31 kW
COP Tj = -7°C
3.38
2.27
Cdh Tj = -7 °C
0.991
0.994
Pdh Tj = +2°C
4.79 kW
4.4 kW
COP Tj = +2°C
4.77
3.2
Cdh Tj = +2 °C
0.985
0.989
Pdh Tj = +7°C
4.9 kW
4.1 kW
COP Tj = +7°C
5.61
3.99
Cdh Tj = +7 °C
0.983
0.985
Pdh Tj = 12°C
3 kW
2.7 kW
COP Tj = 12°C
6.19
5.58
Cdh Tj = +12 °C
0.969
0.969
Pdh Tj = Tbiv
6 kW
6 kW
COP Tj = Tbiv
2.74
1.99
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6 kW
6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
1.99
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
70 °C
70 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2640 kWh
3772 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6 kW
4 kW
El input
1.2 kW
1.6 kW
COP
5.02
2.5
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.15 kW
1.62 kW
Cooling capacity
7.1
8
EER
3.3
4.95
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.1 kW
8 kW
SEER
4.13
5.74
Pdc Tj = 35°C
7.1 kW
8 kW
EER Tj = 35°C
3.3
4.95
Cdc Tj = 35 °C
0.993
0.991
Pdc Tj = 30°C
5.23 kW
5.92 kW
EER Tj = 30°C
3.85
5.7
Cdc Tj = 30 °C
0.989
0.986
Pdc Tj = 25°C
3.36 kW
3.79 kW
EER Tj = 25°C
4.55
6
Cdc Tj = 25 °C
0.98
0.976
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.69
6.75
Cdc Tj = 20 °C
0.972
0.971
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
1031 kWh
836 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
130 %
Prated
8 kW
8 kW
SCOP
4.68
3.34
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.08 kW
7.08 kW
COP Tj = -7°C
3.22
2.27
Cdh Tj = -7 °C
0.993
0.995
Pdh Tj = +2°C
4.4 kW
4.4 kW
COP Tj = +2°C
4.78
3.2
Cdh Tj = +2 °C
0.984
0.989
Pdh Tj = +7°C
5 kW
4.4 kW
COP Tj = +7°C
5.61
4.18
Cdh Tj = +7 °C
0.983
0.986
Pdh Tj = 12°C
3 kW
2.8 kW
COP Tj = 12°C
6.19
5.79
Cdh Tj = +12 °C
0.969
0.969
Pdh Tj = Tbiv
7.08 kW
7.08 kW
COP Tj = Tbiv
3.2
2.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.5 kW
7.4 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
70 °C
70 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.5 kW
0.6 kW
Annual energy consumption Qhe
3528 kWh
4952 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6 kW
4 kW
El input
1.2 kW
1.6 kW
COP
5.02
2.5
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.15 kW
1.62 kW
Cooling capacity
7.1
8
EER
3.3
4.95
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.1 kW
8 kW
SEER
4.07
5.63
Pdc Tj = 35°C
7.1 kW
8 kW
EER Tj = 35°C
3.3
4.95
Cdc Tj = 35 °C
0.99
0.986
Pdc Tj = 30°C
5.23 kW
5.92 kW
EER Tj = 30°C
3.85
5.7
Cdc Tj = 30 °C
0.984
0.979
Pdc Tj = 25°C
3.36 kW
3.79 kW
EER Tj = 25°C
4.55
6
Cdc Tj = 25 °C
0.97
0.965
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.69
6.75
Cdc Tj = 20 °C
0.959
0.958
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Annual energy consumption Qce
1048 kWh
853 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
130 %
Prated
8 kW
8 kW
SCOP
4.67
3.33
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.08 kW
7.08 kW
COP Tj = -7°C
3.22
2.27
Cdh Tj = -7 °C
0.99
0.993
Pdh Tj = +2°C
4.4 kW
4.4 kW
COP Tj = +2°C
4.78
3.2
Cdh Tj = +2 °C
0.976
0.984
Pdh Tj = +7°C
5 kW
4.4 kW
COP Tj = +7°C
5.61
4.18
Cdh Tj = +7 °C
0.975
0.979
Pdh Tj = 12°C
3 kW
2.8 kW
COP Tj = 12°C
6.19
5.79
Cdh Tj = +12 °C
0.955
0.955
Pdh Tj = Tbiv
7.08 kW
7.08 kW
COP Tj = Tbiv
3.2
2.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.5 kW
7.4 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.995
WTOL
70 °C
70 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.5 kW
0.6 kW
Annual energy consumption Qhe
3540 kWh
4964 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8 kW
7 kW
El input
1.59 kW
2.59 kW
COP
5.02
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
3 kW
2.22 kW
Cooling capacity
9
10
EER
3
4.5
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9 kW
10 kW
SEER
3.98
5.73
Pdc Tj = 35°C
9 kW
10 kW
EER Tj = 35°C
3
4.5
Cdc Tj = 35 °C
0.995
0.993
Pdc Tj = 30°C
6.63 kW
7.37 kW
EER Tj = 30°C
3.82
5.68
Cdc Tj = 30 °C
0.991
0.988
Pdc Tj = 25°C
4.26 kW
4.74 kW
EER Tj = 25°C
4.43
6.05
Cdc Tj = 25 °C
0.984
0.981
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.23
6.55
Cdc Tj = 20 °C
0.975
0.972
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
1357 kWh
1047 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
134 %
Prated
10 kW
10 kW
SCOP
4.6
3.42
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.8 kW
8.8 kW
COP Tj = -7°C
3.05
2.15
Cdh Tj = -7 °C
0.995
0.996
Pdh Tj = +2°C
5.4 kW
5.4 kW
COP Tj = +2°C
4.61
3.35
Cdh Tj = +2 °C
0.987
0.991
Pdh Tj = +7°C
5.2 kW
4.8 kW
COP Tj = +7°C
5.7
4.39
Cdh Tj = +7 °C
0.984
0.986
Pdh Tj = 12°C
3.2 kW
2.9 kW
COP Tj = 12°C
6.61
5.99
Cdh Tj = +12 °C
0.969
0.969
Pdh Tj = Tbiv
8.8 kW
8.8 kW
COP Tj = Tbiv
3.05
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9 kW
8.5 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.4
1.7
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
70 °C
70 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1 kW
1.5 kW
Annual energy consumption Qhe
4494 kWh
6033 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8 kW
7 kW
El input
1.59 kW
2.59 kW
COP
5.02
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
3 kW
2.22 kW
Cooling capacity
9
10
EER
3
4.5
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9 kW
10 kW
SEER
3.93
5.64
Pdc Tj = 35°C
9 kW
10 kW
EER Tj = 35°C
3
4.5
Cdc Tj = 35 °C
0.993
0.99
Pdc Tj = 30°C
6.63 kW
7.37 kW
EER Tj = 30°C
3.82
5.68
Cdc Tj = 30 °C
0.987
0.983
Pdc Tj = 25°C
4.26 kW
4.74 kW
EER Tj = 25°C
4.43
6.05
Cdc Tj = 25 °C
0.977
0.972
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.23
6.55
Cdc Tj = 20 °C
0.963
0.959
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Annual energy consumption Qce
1372 kWh
1064 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
134 %
Prated
10 kW
10 kW
SCOP
4.59
3.42
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.8 kW
8.8 kW
COP Tj = -7°C
3.05
2.15
Cdh Tj = -7 °C
0.992
0.995
Pdh Tj = +2°C
5.4 kW
5.4 kW
COP Tj = +2°C
4.61
3.35
Cdh Tj = +2 °C
0.981
0.986
Pdh Tj = +7°C
5.2 kW
4.8 kW
COP Tj = +7°C
5.7
4.39
Cdh Tj = +7 °C
0.976
0.98
Pdh Tj = 12°C
3.2 kW
2.9 kW
COP Tj = 12°C
6.61
5.99
Cdh Tj = +12 °C
0.955
0.955
Pdh Tj = Tbiv
8.8 kW
8.8 kW
COP Tj = Tbiv
3.05
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9 kW
8.5 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.4
1.7
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.996
WTOL
70 °C
70 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1 kW
1.5 kW
Annual energy consumption Qhe
4505 kWh
6042 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5 kW
4 kW
El input
1 kW
1.63 kW
COP
5.02
2.45
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.46 kW
1.11 kW
Cooling capacity
5.1
6
EER
3.5
5.4
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.1 kW
6 kW
SEER
3.89
5.93
Pdc Tj = 35°C
5.1 kW
6 kW
EER Tj = 35°C
3.5
5.4
Cdc Tj = 35 °C
0.99
0.987
Pdc Tj = 30°C
3.76 kW
4.42 kW
EER Tj = 30°C
3.84
5.95
Cdc Tj = 30 °C
0.985
0.98
Pdc Tj = 25°C
2.42 kW
3.3 kW
EER Tj = 25°C
4.07
6.38
Cdc Tj = 25 °C
0.975
0.971
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.57
7
Cdc Tj = 20 °C
0.973
0.97
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
787 kWh
608 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
128 %
Prated
6 kW
6 kW
SCOP
4.7
3.29
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.37 kW
5.31 kW
COP Tj = -7°C
3.38
2.27
Cdh Tj = -7 °C
0.991
0.994
Pdh Tj = +2°C
4.79 kW
4.4 kW
COP Tj = +2°C
4.77
3.2
Cdh Tj = +2 °C
0.985
0.989
Pdh Tj = +7°C
4.9 kW
4.1 kW
COP Tj = +7°C
5.61
3.99
Cdh Tj = +7 °C
0.983
0.985
Pdh Tj = 12°C
3 kW
2.7 kW
COP Tj = 12°C
6.19
5.58
Cdh Tj = +12 °C
0.969
0.969
Pdh Tj = Tbiv
6 kW
6 kW
COP Tj = Tbiv
2.74
1.99
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6 kW
6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
1.99
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
70 °C
70 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2640 kWh
3772 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6 kW
4 kW
El input
1.2 kW
1.6 kW
COP
5.02
2.5
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.15 kW
1.62 kW
Cooling capacity
7.1
8
EER
3.3
4.95
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.1 kW
8 kW
SEER
4.13
5.74
Pdc Tj = 35°C
7.1 kW
8 kW
EER Tj = 35°C
3.3
4.95
Cdc Tj = 35 °C
0.993
0.991
Pdc Tj = 30°C
5.23 kW
5.92 kW
EER Tj = 30°C
3.85
5.7
Cdc Tj = 30 °C
0.989
0.986
Pdc Tj = 25°C
3.36 kW
3.79 kW
EER Tj = 25°C
4.55
6
Cdc Tj = 25 °C
0.98
0.976
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.69
6.75
Cdc Tj = 20 °C
0.972
0.971
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
1031 kWh
836 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
130 %
Prated
8 kW
8 kW
SCOP
4.68
3.34
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.08 kW
7.08 kW
COP Tj = -7°C
3.22
2.27
Cdh Tj = -7 °C
0.993
0.995
Pdh Tj = +2°C
4.4 kW
4.4 kW
COP Tj = +2°C
4.78
3.2
Cdh Tj = +2 °C
0.984
0.989
Pdh Tj = +7°C
5 kW
4.4 kW
COP Tj = +7°C
5.61
4.18
Cdh Tj = +7 °C
0.983
0.986
Pdh Tj = 12°C
3 kW
2.8 kW
COP Tj = 12°C
6.19
5.79
Cdh Tj = +12 °C
0.969
0.969
Pdh Tj = Tbiv
7.08 kW
7.08 kW
COP Tj = Tbiv
3.2
2.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.5 kW
7.4 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
70 °C
70 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.5 kW
0.6 kW
Annual energy consumption Qhe
3528 kWh
4952 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6 kW
4 kW
El input
1.2 kW
1.6 kW
COP
5.02
2.5
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.15 kW
1.62 kW
Cooling capacity
7.1
8
EER
3.3
4.95
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.1 kW
8 kW
SEER
4.07
5.63
Pdc Tj = 35°C
7.1 kW
8 kW
EER Tj = 35°C
3.3
4.95
Cdc Tj = 35 °C
0.99
0.986
Pdc Tj = 30°C
5.23 kW
5.92 kW
EER Tj = 30°C
3.85
5.7
Cdc Tj = 30 °C
0.984
0.979
Pdc Tj = 25°C
3.36 kW
3.79 kW
EER Tj = 25°C
4.55
6
Cdc Tj = 25 °C
0.97
0.965
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.69
6.75
Cdc Tj = 20 °C
0.959
0.958
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Annual energy consumption Qce
1048 kWh
853 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
130 %
Prated
8 kW
8 kW
SCOP
4.67
3.33
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.08 kW
7.08 kW
COP Tj = -7°C
3.22
2.27
Cdh Tj = -7 °C
0.99
0.993
Pdh Tj = +2°C
4.4 kW
4.4 kW
COP Tj = +2°C
4.78
3.2
Cdh Tj = +2 °C
0.976
0.984
Pdh Tj = +7°C
5 kW
4.4 kW
COP Tj = +7°C
5.61
4.18
Cdh Tj = +7 °C
0.975
0.979
Pdh Tj = 12°C
3 kW
2.8 kW
COP Tj = 12°C
6.19
5.79
Cdh Tj = +12 °C
0.955
0.955
Pdh Tj = Tbiv
7.08 kW
7.08 kW
COP Tj = Tbiv
3.2
2.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.5 kW
7.4 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.995
WTOL
70 °C
70 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.5 kW
0.6 kW
Annual energy consumption Qhe
3540 kWh
4964 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8 kW
7 kW
El input
1.59 kW
2.59 kW
COP
5.02
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
3 kW
2.22 kW
Cooling capacity
9
10
EER
3
4.5
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9 kW
10 kW
SEER
3.98
5.73
Pdc Tj = 35°C
9 kW
10 kW
EER Tj = 35°C
3
4.5
Cdc Tj = 35 °C
0.995
0.993
Pdc Tj = 30°C
6.63 kW
7.37 kW
EER Tj = 30°C
3.82
5.68
Cdc Tj = 30 °C
0.991
0.988
Pdc Tj = 25°C
4.26 kW
4.74 kW
EER Tj = 25°C
4.43
6.05
Cdc Tj = 25 °C
0.984
0.981
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.23
6.55
Cdc Tj = 20 °C
0.975
0.972
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
1357 kWh
1047 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
134 %
Prated
10 kW
10 kW
SCOP
4.6
3.42
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.8 kW
8.8 kW
COP Tj = -7°C
3.05
2.15
Cdh Tj = -7 °C
0.995
0.996
Pdh Tj = +2°C
5.4 kW
5.4 kW
COP Tj = +2°C
4.61
3.35
Cdh Tj = +2 °C
0.987
0.991
Pdh Tj = +7°C
5.2 kW
4.8 kW
COP Tj = +7°C
5.7
4.39
Cdh Tj = +7 °C
0.984
0.986
Pdh Tj = 12°C
3.2 kW
2.9 kW
COP Tj = 12°C
6.61
5.99
Cdh Tj = +12 °C
0.969
0.969
Pdh Tj = Tbiv
8.8 kW
8.8 kW
COP Tj = Tbiv
3.05
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9 kW
8.5 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.4
1.7
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
70 °C
70 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1 kW
1.5 kW
Annual energy consumption Qhe
4494 kWh
6033 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8 kW
7 kW
El input
1.59 kW
2.59 kW
COP
5.02
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
3 kW
2.22 kW
Cooling capacity
9
10
EER
3
4.5
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9 kW
10 kW
SEER
3.93
5.64
Pdc Tj = 35°C
9 kW
10 kW
EER Tj = 35°C
3
4.5
Cdc Tj = 35 °C
0.993
0.99
Pdc Tj = 30°C
6.63 kW
7.37 kW
EER Tj = 30°C
3.82
5.68
Cdc Tj = 30 °C
0.987
0.983
Pdc Tj = 25°C
4.26 kW
4.74 kW
EER Tj = 25°C
4.43
6.05
Cdc Tj = 25 °C
0.977
0.972
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.23
6.55
Cdc Tj = 20 °C
0.963
0.959
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Annual energy consumption Qce
1372 kWh
1064 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
134 %
Prated
10 kW
10 kW
SCOP
4.59
3.42
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.8 kW
8.8 kW
COP Tj = -7°C
3.05
2.15
Cdh Tj = -7 °C
0.992
0.995
Pdh Tj = +2°C
5.4 kW
5.4 kW
COP Tj = +2°C
4.61
3.35
Cdh Tj = +2 °C
0.981
0.986
Pdh Tj = +7°C
5.2 kW
4.8 kW
COP Tj = +7°C
5.7
4.39
Cdh Tj = +7 °C
0.976
0.98
Pdh Tj = 12°C
3.2 kW
2.9 kW
COP Tj = 12°C
6.61
5.99
Cdh Tj = +12 °C
0.955
0.955
Pdh Tj = Tbiv
8.8 kW
8.8 kW
COP Tj = Tbiv
3.05
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9 kW
8.5 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.4
1.7
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.996
WTOL
70 °C
70 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1 kW
1.5 kW
Annual energy consumption Qhe
4505 kWh
6042 kWh