1,500 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.76 kW
4.53 kW
El input
1.00 kW
1.54 kW
COP
4.76
2.94
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
1.37 kW
Cooling capacity
4.33
EER
3.16
EN 14825
+7°C/+12°C
Pdesignc
4.33 kW
SEER
4.28
Pdc Tj = 35°C
4.33 kW
EER Tj = 35°C
3.16
Pdc Tj = 30°C
3.16 kW
EER Tj = 30°C
3.85
Cdc Tj = 30 °C
1.000
Pdc Tj = 25°C
2.67 kW
EER Tj = 25°C
4.85
Cdc Tj = 25 °C
1.000
Pdc Tj = 20°C
2.98 kW
EER Tj = 20°C
6.34
Cdc Tj = 20 °C
1.000
Poff
19 W
PTO
0 W
PSB
19 W
PCK
30 W
Annual energy consumption Qce
606 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
57 dB(A)
57 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
135 %
Prated
4.00 kW
4.00 kW
SCOP
4.56
3.45
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
3.90 kW
3.90 kW
COP Tj = -7°C
3.01
2.26
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
2.40 kW
2.40 kW
COP Tj = +2°C
4.53
3.32
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
2.80 kW
2.80 kW
COP Tj = +7°C
5.57
4.35
Cdh Tj = +7 °C
0.969
0.976
Pdh Tj = 12°C
3.30 kW
3.30 kW
COP Tj = 12°C
7.01
6.01
Cdh Tj = +12 °C
0.963
0.969
Pdh Tj = Tbiv
3.90 kW
3.90 kW
COP Tj = Tbiv
3.01
2.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.80 kW
3.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.77
2.06
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
19 W
19 W
PTO
22 W
22 W
PSB
19 W
19 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.20 kW
0.10 kW
Annual energy consumption Qhe
1988 kWh
2624 kWh