Certificate holders

Subtype

Ecodan Multi Inverter 4+170D

Certificate Holder
Mitsubishi Electric Air Conditioning Systems Europe LTD
Nettlehill Road, Houston Industrial Estate
EH54 5EQ Livingston
United Kingdom
Registration number
037-0095-22 / rev. 1
Certification Body
SZU - Strojirensky zkusebni ustav (Engineering Test Institute, Public Enterprise)
Subtype title
Ecodan Multi Inverter 4+170D
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,400 kg

Certification Date
21.11.2022
Testing basis
hp Keymark scheme rules rev. no. 9
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

PXZ-4F75VG + EHST17D-*M*D
Configure model
Model name
PXZ-4F75VG + EHST17D-*M*D
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.5 kW

7.5 kW

El input

1.8 kW

2.92 kW

COP

4.17

2.57

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

154 %

113 %

Prated

6.1 kW

6.1 kW

SCOP

3.92

2.91

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

5.4 kW

5.4 kW

COP Tj = -7°C

2.44

1.57

Cdh Tj = -7 °C

0.993

0.996

Pdh Tj = +2°C

3.31 kW

3.58 kW

COP Tj = +2°C

4.08

3.04

Cdh Tj = +2 °C

0.982

0.987

Pdh Tj = +7°C

2.16 kW

2.25 kW

COP Tj = +7°C

5.07

3.96

Cdh Tj = +7 °C

0.965

0.974

Pdh Tj = 12°C

1.59 kW

1.49 kW

COP Tj = 12°C

5.51

4.51

Cdh Tj = +12 °C

0.948

0.955

Pdh Tj = Tbiv

5.4 kW

5.4 kW

COP Tj = Tbiv

2.44

1.57

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.01 kW

4.51 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.31

1.33

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.993

0.996

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.09 kW

1.59 kW

Annual energy consumption Qhe

3212 kWh

4335 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.83

Heating up time

2:06 h:min

Standby power input

35 W

Reference hot water temperature

55.5 °C

Mixed water at 40°C

236 l

PXZ-4F75VG + ERST17D-*M*D
Configure model
Model name
PXZ-4F75VG + ERST17D-*M*D
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.5 kW

7.5 kW

El input

1.8 kW

2.92 kW

COP

4.17

2.57

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

154 %

113 %

Prated

6.1 kW

6.1 kW

SCOP

3.92

2.91

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

5.4 kW

5.4 kW

COP Tj = -7°C

2.44

1.57

Cdh Tj = -7 °C

0.993

0.996

Pdh Tj = +2°C

3.31 kW

3.58 kW

COP Tj = +2°C

4.08

3.04

Cdh Tj = +2 °C

0.982

0.987

Pdh Tj = +7°C

2.16 kW

2.25 kW

COP Tj = +7°C

5.07

3.96

Cdh Tj = +7 °C

0.965

0.974

Pdh Tj = 12°C

1.59 kW

1.49 kW

COP Tj = 12°C

5.51

4.51

Cdh Tj = +12 °C

0.948

0.955

Pdh Tj = Tbiv

5.4 kW

5.4 kW

COP Tj = Tbiv

2.44

1.57

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.01 kW

4.51 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.31

1.33

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.993

0.996

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.09 kW

1.59 kW

Annual energy consumption Qhe

3212 kWh

4335 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.83

Heating up time

2:06 h:min

Standby power input

35 W

Reference hot water temperature

55.5 °C

Mixed water at 40°C

236 l

PXZ-4F75VG + EHST17D-*M*E
Configure model
Model name
PXZ-4F75VG + EHST17D-*M*E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.5 kW

7.5 kW

El input

1.8 kW

2.92 kW

COP

4.17

2.57

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

154 %

113 %

Prated

6.1 kW

6.1 kW

SCOP

3.92

2.91

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.4 kW

5.4 kW

COP Tj = -7°C

2.44

1.57

Cdh Tj = -7 °C

0.993

0.996

Pdh Tj = +2°C

3.31 kW

3.58 kW

COP Tj = +2°C

4.08

3.04

Cdh Tj = +2 °C

0.982

0.987

Pdh Tj = +7°C

2.16 kW

2.25 kW

COP Tj = +7°C

5.07

3.96

Cdh Tj = +7 °C

0.965

0.974

Pdh Tj = 12°C

1.59 kW

1.49 kW

COP Tj = 12°C

5.51

4.51

Cdh Tj = +12 °C

0.948

0.955

Pdh Tj = Tbiv

5.4 kW

5.4 kW

COP Tj = Tbiv

2.44

1.57

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.01 kW

4.51 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.31

1.33

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.993

0.996

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.09 kW

1.59 kW

Annual energy consumption Qhe

3212 kWh

4335 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

121 %

COP

2.95

Heating up time

2:21 h:min

Standby power input

30.2 W

Reference hot water temperature

53 °C

Mixed water at 40°C

236 l

PXZ-4F75VG + ERST17D-*M*E
Configure model
Model name
PXZ-4F75VG + ERST17D-*M*E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.5 kW

7.5 kW

El input

1.8 kW

2.92 kW

COP

4.17

2.57

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

154 %

113 %

Prated

6.1 kW

6.1 kW

SCOP

3.92

2.91

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.4 kW

5.4 kW

COP Tj = -7°C

2.44

1.57

Cdh Tj = -7 °C

0.993

0.996

Pdh Tj = +2°C

3.31 kW

3.58 kW

COP Tj = +2°C

4.08

3.04

Cdh Tj = +2 °C

0.982

0.987

Pdh Tj = +7°C

2.16 kW

2.25 kW

COP Tj = +7°C

5.07

3.96

Cdh Tj = +7 °C

0.965

0.974

Pdh Tj = 12°C

1.59 kW

1.49 kW

COP Tj = 12°C

5.51

4.51

Cdh Tj = +12 °C

0.948

0.955

Pdh Tj = Tbiv

5.4 kW

5.4 kW

COP Tj = Tbiv

2.44

1.57

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.01 kW

4.51 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.31

1.33

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.993

0.996

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.09 kW

1.59 kW

Annual energy consumption Qhe

3212 kWh

4335 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

121 %

COP

2.95

Heating up time

2:21 h:min

Standby power input

30.2 W

Reference hot water temperature

53 °C

Mixed water at 40°C

236 l