0,950 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.83 kW
3.18 kW
El input
0.59 kW
1.18 kW
COP
4.81
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
139 %
Prated
6.40 kW
5.90 kW
SCOP
4.65
3.55
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.43 kW
5.98 kW
COP Tj = +2°C
2.87
2.16
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
4.16 kW
3.87 kW
COP Tj = +7°C
4.24
3.22
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
1.95 kW
1.81 kW
COP Tj = 12°C
7.36
5.33
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
6.43 kW
5.98 kW
COP Tj = Tbiv
2.87
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.43 kW
5.98 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.87
2.16
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
75 °C
75 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1837 kWh
2221 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
162 %
121 %
Prated
5.40 kW
5.30 kW
SCOP
4.12
3.10
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.46 kW
3.20 kW
COP Tj = -7°C
3.44
2.65
Cdh Tj = -7 °C
0.980
0.990
Pdh Tj = +2°C
2.08 kW
2.12 kW
COP Tj = +2°C
5.47
3.80
Cdh Tj = +2 °C
0.960
0.970
Pdh Tj = +7°C
1.75 kW
1.73 kW
COP Tj = +7°C
6.40
5.19
Cdh Tj = +7 °C
0.940
0.950
Pdh Tj = 12°C
1.93 kW
1.92 kW
COP Tj = 12°C
7.01
5.89
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
4.64 kW
4.33 kW
COP Tj = Tbiv
2.42
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.04 kW
3.69 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.11
1.60
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
75 °C
75 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.36 kW
1.61 kW
Annual energy consumption Qhe
3232 kWh
4211 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.64
4.33
COP Tj = -15°C (if TOL<-20°C)
2.42
1.92
Cdh Tj = -15 °C
0.990
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
169 %
130 %
Prated
6.20 kW
6.20 kW
SCOP
4.30
3.33
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.50 kW
5.60 kW
COP Tj = -7°C
2.59
2.01
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.06 kW
3.54 kW
COP Tj = +2°C
4.64
3.41
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.29 kW
2.24 kW
COP Tj = +7°C
6.07
4.85
Cdh Tj = +7 °C
0.960
0.970
Pdh Tj = 12°C
1.95 kW
1.90 kW
COP Tj = 12°C
7.23
5.83
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
5.50 kW
5.60 kW
COP Tj = Tbiv
2.59
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.47 kW
5.14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.40
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
75 °C
75 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.73 kW
1.06 kW
Annual energy consumption Qhe
2977 kWh
3851 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
118 %
COP
3.06
Heating up time
3:09 h:min
Standby power input
98.1 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
359 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
75 %
COP
1.84
Heating up time
3:13 h:min
Standby power input
132.9 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
359 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
118 %
COP
2.77
Heating up time
3:15 h:min
Standby power input
87 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
359 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.83 kW
3.18 kW
El input
0.59 kW
1.18 kW
COP
4.81
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
188 %
140 %
Prated
7.10 kW
5.70 kW
SCOP
4.77
3.57
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.44 kW
5.94 kW
COP Tj = +2°C
3.00
2.15
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
4.32 kW
3.70 kW
COP Tj = +7°C
4.33
3.13
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
1.89 kW
1.86 kW
COP Tj = 12°C
7.35
5.65
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
6.44 kW
5.94 kW
COP Tj = Tbiv
3.00
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.10 kW
5.94 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.00
2.15
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1988 kWh
2135 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
152 %
115 %
Prated
7.30 kW
6.60 kW
SCOP
3.88
2.96
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.08 kW
3.74 kW
COP Tj = -7°C
3.00
2.39
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.53 kW
2.41 kW
COP Tj = +2°C
5.20
3.68
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
1.87 kW
1.85 kW
COP Tj = +7°C
6.23
4.70
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
1.84 kW
1.81 kW
COP Tj = 12°C
7.00
5.49
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
6.03 kW
5.40 kW
COP Tj = Tbiv
2.38
1.97
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.05 kW
3.32 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.04
1.60
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.25 kW
3.28 kW
Annual energy consumption Qhe
4638 kWh
5505 kWh
Pdh Tj = -15°C (if TOL<-20°C)
6.03
5.40
COP Tj = -15°C (if TOL<-20°C)
2.38
1.97
Cdh Tj = -15 °C
0.990
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
161 %
131 %
Prated
6.60 kW
6.60 kW
SCOP
4.11
3.35
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.45 kW
5.98 kW
COP Tj = -7°C
2.61
2.09
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.52 kW
3.55 kW
COP Tj = +2°C
4.17
3.51
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.22 kW
2.34 kW
COP Tj = +7°C
6.15
4.51
Cdh Tj = +7 °C
0.960
0.970
Pdh Tj = 12°C
1.85 kW
1.82 kW
COP Tj = 12°C
7.09
5.71
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
5.45 kW
5.98 kW
COP Tj = Tbiv
2.61
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.89 kW
5.25 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.23
1.77
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.71 kW
1.35 kW
Annual energy consumption Qhe
3319 kWh
4076 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
117 %
COP
2.82
Heating up time
3:08 h:min
Standby power input
92.4 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
358 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
77 %
COP
1.88
Heating up time
3:13 h:min
Standby power input
131.6 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
358 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
103 %
COP
2.42
Heating up time
3:17 h:min
Standby power input
91 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
358 l