Certificate holders

Subtype

Bosch CS5800iAW 4/5/7 OR180 MCP-S

Certificate Holder
Bosch Thermotechnik GmbH
Junkersstraße 20 - 24
73249 Wernau
Germany
Registration number
011-1W0675
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Bosch CS5800iAW 4/5/7 OR180 MCP-S
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,950 kg

Certification Date
28.08.2023
Testing basis
HP KEYMARK certification scheme rules V12
Generate PDF Export model CSV
  • Number of models 3

Models

CS5800iAW 7 OR180 MCP-S
Configure model
Model name
CS5800iAW 7 OR180 MCP-S
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.83 kW

3.18 kW

El input

0.59 kW

1.18 kW

COP

4.81

2.7

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

140 %

Prated

7.10 kW

5.70 kW

SCOP

4.77

3.57

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.44 kW

5.94 kW

COP Tj = +2°C

3.00

2.15

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.32 kW

3.70 kW

COP Tj = +7°C

4.33

3.13

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

1.89 kW

1.86 kW

COP Tj = 12°C

7.35

5.65

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

6.44 kW

5.94 kW

COP Tj = Tbiv

3.00

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.10 kW

5.94 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.00

2.15

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

32 W

32 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1988 kWh

2135 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

115 %

Prated

7.30 kW

6.60 kW

SCOP

3.88

2.96

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.08 kW

3.74 kW

COP Tj = -7°C

3.00

2.39

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.53 kW

2.41 kW

COP Tj = +2°C

5.20

3.68

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

1.87 kW

1.85 kW

COP Tj = +7°C

6.23

4.70

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

1.84 kW

1.81 kW

COP Tj = 12°C

7.00

5.49

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

6.03 kW

5.40 kW

COP Tj = Tbiv

2.38

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.05 kW

3.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.04

1.60

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

32 W

32 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.25 kW

3.28 kW

Annual energy consumption Qhe

4638 kWh

5505 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.03

5.40

COP Tj = -15°C (if TOL<-20°C)

2.38

1.97

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

131 %

Prated

6.60 kW

6.60 kW

SCOP

4.11

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.45 kW

5.98 kW

COP Tj = -7°C

2.61

2.09

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.52 kW

3.55 kW

COP Tj = +2°C

4.17

3.51

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.22 kW

2.34 kW

COP Tj = +7°C

6.15

4.51

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

1.85 kW

1.82 kW

COP Tj = 12°C

7.09

5.71

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

5.45 kW

5.98 kW

COP Tj = Tbiv

2.61

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.89 kW

5.25 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.23

1.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

32 W

32 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.71 kW

1.35 kW

Annual energy consumption Qhe

3319 kWh

4076 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

107 %

COP

2.55

Heating up time

2:09 h:min

Standby power input

85.2 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

235 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

67 %

COP

1.62

Heating up time

2:13 h:min

Standby power input

120.1 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

235 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

89 %

COP

2.04

Heating up time

1:41 h:min

Standby power input

91 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

235 l

CS5800iAW 4 OR180 MCP-S
Configure model
Model name
CS5800iAW 4 OR180 MCP-S
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.83 kW

1.97 kW

El input

0.59 kW

0.8 kW

COP

4.81

2.47

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

40 dB(A)

40 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

124 %

Prated

4.30 kW

3.80 kW

SCOP

4.53

3.18

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.52 kW

3.82 kW

COP Tj = +2°C

3.36

2.17

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

2.80 kW

2.44 kW

COP Tj = +7°C

5.16

3.10

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

1.82 kW

1.82 kW

COP Tj = 12°C

6.72

5.00

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

4.52 kW

3.82 kW

COP Tj = Tbiv

3.36

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.52 kW

3.82 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.36

2.17

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

14 W

14 W

PSB

15 W

15 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1267 kWh

1596 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

40 dB(A)

40 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

144 %

99 %

Prated

3.80 kW

3.20 kW

SCOP

3.68

2.55

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

2.27 kW

1.89 kW

COP Tj = -7°C

3.43

2.27

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

1.87 kW

1.76 kW

COP Tj = +2°C

4.60

2.98

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

1.60 kW

1.60 kW

COP Tj = +7°C

5.25

4.26

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

1.82 kW

1.80 kW

COP Tj = 12°C

6.64

5.23

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

3.14 kW

2.67 kW

COP Tj = Tbiv

2.52

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.24 kW

2.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.92

1.41

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

14 W

14 W

PSB

15 W

15 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.56 kW

1.09 kW

Annual energy consumption Qhe

2546 kWh

3095 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.14

2.67

COP Tj = -15°C (if TOL<-20°C)

2.52

1.83

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

40 dB(A)

40 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

162 %

121 %

Prated

4.40 kW

4.00 kW

SCOP

4.14

3.09

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.93 kW

3.48 kW

COP Tj = -7°C

2.65

2.15

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.50 kW

2.17 kW

COP Tj = +2°C

4.50

3.23

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

1.65 kW

1.55 kW

COP Tj = +7°C

6.00

4.38

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

1.97 kW

1.79 kW

COP Tj = 12°C

7.44

5.39

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

3.93 kW

3.48 kW

COP Tj = Tbiv

2.65

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.65 kW

2.95 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

14 W

14 W

PSB

15 W

15 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.75 kW

1.05 kW

Annual energy consumption Qhe

2198 kWh

2672 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

108 %

COP

2.55

Heating up time

2:10 h:min

Standby power input

87.5 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

71 %

COP

1.71

Heating up time

2:25 h:min

Standby power input

120.8 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

92 %

COP

2.1

Heating up time

2:00 h:min

Standby power input

89 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

CS5800iAW 5 OR180 MCP-S
Configure model
Model name
CS5800iAW 5 OR180 MCP-S
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.83 kW

3.18 kW

El input

0.59 kW

1.18 kW

COP

4.81

2.7

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

139 %

Prated

6.40 kW

5.90 kW

SCOP

4.65

3.55

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.43 kW

5.98 kW

COP Tj = +2°C

2.87

2.16

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.16 kW

3.87 kW

COP Tj = +7°C

4.24

3.22

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

1.95 kW

1.81 kW

COP Tj = 12°C

7.36

5.33

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

6.43 kW

5.98 kW

COP Tj = Tbiv

2.87

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.43 kW

5.98 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.87

2.16

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

16 W

16 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

31 W

31 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1837 kWh

2221 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

162 %

121 %

Prated

5.40 kW

5.30 kW

SCOP

4.12

3.10

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.46 kW

3.20 kW

COP Tj = -7°C

3.44

2.65

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

2.08 kW

2.12 kW

COP Tj = +2°C

5.47

3.80

Cdh Tj = +2 °C

0.960

0.970

Pdh Tj = +7°C

1.75 kW

1.73 kW

COP Tj = +7°C

6.40

5.19

Cdh Tj = +7 °C

0.940

0.950

Pdh Tj = 12°C

1.93 kW

1.92 kW

COP Tj = 12°C

7.01

5.89

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

4.64 kW

4.33 kW

COP Tj = Tbiv

2.42

1.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.04 kW

3.69 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.11

1.60

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

16 W

16 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

31 W

31 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.36 kW

1.61 kW

Annual energy consumption Qhe

3232 kWh

4211 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.64

4.33

COP Tj = -15°C (if TOL<-20°C)

2.42

1.92

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

130 %

Prated

6.20 kW

6.20 kW

SCOP

4.30

3.33

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.50 kW

5.60 kW

COP Tj = -7°C

2.59

2.01

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.06 kW

3.54 kW

COP Tj = +2°C

4.64

3.41

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.29 kW

2.24 kW

COP Tj = +7°C

6.07

4.85

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

1.95 kW

1.90 kW

COP Tj = 12°C

7.23

5.83

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

5.50 kW

5.60 kW

COP Tj = Tbiv

2.59

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.47 kW

5.14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

75 °C

75 °C

Poff

16 W

16 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

31 W

31 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.73 kW

1.06 kW

Annual energy consumption Qhe

2977 kWh

3851 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

99 %

COP

2.35

Heating up time

2:09 h:min

Standby power input

86.7 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

66 %

COP

1.6

Heating up time

2:13 h:min

Standby power input

121.2 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

234 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

87 %

COP

2

Heating up time

1:39 h:min

Standby power input

87 W

Reference hot water temperature

52.4 °C

Mixed water at 40°C

234 l