0,800 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.70 kW
9.20 kW
El input
1.64 kW
2.89 kW
COP
5.29
3.19
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
dB(A)
dB(A)
Sound power level outdoor
57 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
213 %
156 %
Prated
10.30 kW
10.00 kW
SCOP
5.39
3.98
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.31 kW
8.98 kW
COP Tj = -7°C
3.19
2.18
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
5.66 kW
5.58 kW
COP Tj = +2°C
5.46
4.09
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
4.44 kW
4.32 kW
COP Tj = +7°C
7.15
5.34
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.01 kW
4.80 kW
COP Tj = 12°C
8.91
6.51
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
10.31 kW
9.97 kW
COP Tj = Tbiv
2.70
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.31 kW
9.97 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.70
1.90
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
13 W
13 W
PTO
13 W
13 W
PSB
13 W
13 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3831 kWh
5196 kWh