Certificate holders

Subtype

ZHHH-01-15K-R290-R5-M

Certificate Holder
JBG-2 Sp. z o.o.
ul. Gajowa 5
43-254 Warszowice
Poland
Registration number
037-0139-23
Certification Body
SZU - Strojirensky zkusebni ustav (Engineering Test Institute, Public Enterprise)
Subtype title
ZHHH-01-15K-R290-R5-M
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,800 kg

Certification Date
21.11.2023
Testing basis
HP Keymark certification scheme rules rev. no.12
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

ZHHH-01-15K-R290-R5-M + BSEM01-0000
Configure model
Model name
ZHHH-01-15K-R290-R5-M + BSEM01-0000
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.79 kW

13.93 kW

El input

2.06 kW

5.17 kW

COP

4.76

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

dB(A)

dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

196 %

148 %

Prated

10.22 kW

10.16 kW

SCOP

4.96

3.77

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.04 kW

8.99 kW

COP Tj = -7°C

3.36

2.55

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.69 kW

5.31 kW

COP Tj = +2°C

4.98

3.76

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.63 kW

3.42 kW

COP Tj = +7°C

5.89

4.50

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.04 kW

2.93 kW

COP Tj = 12°C

7.17

5.51

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

10.23 kW

9.97 kW

COP Tj = Tbiv

2.92

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.23 kW

9.97 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.92

2.19

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

19 W

19 W

PTO

20 W

20 W

PSB

19 W

19 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4255 kWh

5577 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

232 %

172 %

Prated

10.25 kW

10.20 kW

SCOP

5.89

4.37

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.25 kW

10.20 kW

COP Tj = +2°C

3.54

2.67

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

6.66 kW

6.78 kW

COP Tj = +7°C

5.34

3.86

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

3.37 kW

3.02 kW

COP Tj = 12°C

7.31

5.30

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

10.25 kW

10.20 kW

COP Tj = Tbiv

3.54

2.67

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.25 kW

10.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.54

2.67

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

19 W

19 W

PTO

20 W

20 W

PSB

19 W

19 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2328 kWh

3120 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

163 %

131 %

Prated

13.20 kW

13.27 kW

SCOP

4.15

3.36

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

8.06 kW

8.13 kW

COP Tj = -7°C

3.39

2.75

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

4.89 kW

5.00 kW

COP Tj = +2°C

5.02

4.05

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

3.39 kW

3.27 kW

COP Tj = +7°C

6.63

5.32

Cdh Tj = +7 °C

0.960

0.990

Pdh Tj = 12°C

3.43 kW

3.25 kW

COP Tj = 12°C

7.61

6.38

Cdh Tj = +12 °C

0.960

0.990

Pdh Tj = Tbiv

10.65 kW

10.94 kW

COP Tj = Tbiv

2.67

2.06

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.06 kW

8.93 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.90

1.53

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

19 W

19 W

PTO

20 W

20 W

PSB

19 W

19 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.14 kW

4.34 kW

Annual energy consumption Qhe

7840 kWh

9743 kWh

Pdh Tj = -15°C (if TOL<-20°C)

10.65

10.94

COP Tj = -15°C (if TOL<-20°C)

2.67

2.06

Cdh Tj = -15 °C

1.000

1.000