Certificate holders

Subtype

Aquapura Monobloc 300

Certificate Holder
Energie

4570-311 Laúndos - Póvoa de Varzim
Portugal
Registration number
011-1W0640
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Aquapura Monobloc 300
Driving energy
Electricity
Heat Pump Type
Heat Pump for Domestic Hot Water (DHW)
Refrigerant
R134a
Mass of Refrigerant

1,200 kg

Certification Date
02.08.2023
Testing basis
HP KEYMARK certification scheme rules V12
Generate PDF Export model CSV
  • Number of models 2

Models

Aquapura Monobloc 300i
Configure model
Model name
Aquapura Monobloc 300i
Units
Indoor
Climate zone (for heating)
Colder + Warmer
Heat Source
Outdoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Domestic Hot Water (DHW)

Warmer Climate

EN 12102-2

Sound power level indoor

56 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

152 %

COP

3.70

Heating up time

6:29 h:min

Standby power input

27.3 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

315 l

Colder Climate

EN 12102-2

Sound power level indoor

57 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

109 %

COP

2.60

Heating up time

10:20 h:min

Standby power input

38.4 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

304 l

Average Climate

EN 12102-2

Sound power level indoor

56 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

127 %

COP

3.10

Heating up time

8:58 h:min

Standby power input

27.5 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

309 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed

Aquapura Monobloc 300ix
Configure model
Model name
Aquapura Monobloc 300ix
Units
Indoor
Climate zone (for heating)
Colder + Warmer
Heat Source
Outdoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Domestic Hot Water (DHW)

Warmer Climate

EN 12102-2

Sound power level indoor

56 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

152 %

COP

3.70

Heating up time

6:29 h:min

Standby power input

27.3 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

315 l

Colder Climate

EN 12102-2

Sound power level indoor

56 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

109 %

COP

2.60

Heating up time

10:20 h:min

Standby power input

38.4 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

304 l

Average Climate

EN 12102-2

Sound power level indoor

56 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

127 %

COP

3.10

Heating up time

8:58 h:min

Standby power input

27.5 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

309 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed