Aquapura Monobloc 270

Certificate Holder
Energie

4570-311 Laúndos - Póvoa de Varzim
Portugal
Registration number
011-1W0639
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Aquapura Monobloc 270
Driving energy
Electricity
Heat Pump Type
Heat Pump for Domestic Hot Water (DHW)
Refrigerant
R134a
Mass of Refrigerant

1,200 kg

Certification Date
02.08.2023
Testing basis
HP KEYMARK certification scheme rules V12
Generate PDF Export model CSV
  • Number of models 2

Models

Aquapura Monobloc 270i
Configure model
Model name
Aquapura Monobloc 270i
Units
Indoor
Climate zone (for heating)
Warmer
Heat Source
Outdoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Domestic Hot Water (DHW)

Warmer Climate

EN 12102-2

Sound power level indoor

55 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

161 %

COP

3.90

Heating up time

5:57 h:min

Standby power input

24.3 W

Reference hot water temperature

52.0 °C

Mixed water at 40°C

288 l

Average Climate

EN 12102-2

Sound power level indoor

55 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

136 %

COP

3.30

Heating up time

6:52 h:min

Standby power input

26.7 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

293 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed

Aquapura Monobloc 270ix
Configure model
Model name
Aquapura Monobloc 270ix
Units
Indoor
Climate zone (for heating)
Warmer
Heat Source
Outdoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
Yes

Domestic Hot Water (DHW)

Warmer Climate

EN 12102-2

Sound power level indoor

55 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

161 %

COP

3.90

Heating up time

5:57 h:min

Standby power input

24.3 W

Reference hot water temperature

52.0 °C

Mixed water at 40°C

288 l

Average Climate

EN 12102-2

Sound power level indoor

55 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

136 %

COP

3.30

Heating up time

6:52 h:min

Standby power input

26.7 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

293 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed