Certificate holders

Subtype

HRC70 25 kW

Certificate Holder
Intuis
Rue de la République
80210 Feuquières‑en‑Vimeu
France
Registration number
007-DP0189
Certification Body
Kiwa Nederland B.V.
Subtype title
HRC70 25 kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,900 kg

Certification Date
26.04.2024
Testing basis
European KEYMARK Scheme for Heat Pumps (v11)
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

HRC70 25 kW /3 tri
Configure model
Model name
HRC70 25 kW /3 tri
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.90 kW

10.10 kW

El input

2.37 kW

3.16 kW

COP

4.60

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

150 %

116 %

Prated

21.00 kW

18.00 kW

SCOP

3.83

2.97

Tbiv

-6 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

17.10 kW

14.70 kW

COP Tj = -7°C

2.58

1.97

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

11.12 kW

11.22 kW

COP Tj = +2°C

3.79

2.99

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

11.12 kW

10.90 kW

COP Tj = +7°C

5.61

4.51

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

12.45 kW

12.21 kW

COP Tj = 12°C

5.84

4.81

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

17.36 kW

14.92 kW

COP Tj = Tbiv

2.66

1.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.25 kW

13.97 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

70 °C

70 °C

Poff

7 W

7 W

PTO

10 W

10 W

PSB

7 W

7 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.75 kW

4.03 kW

Annual energy consumption Qhe

11314 kWh

12525 kWh