Certificate holders

Subtype

HTi70 11 kW

Certificate Holder
Intuis
Rue de la République
80210 Feuquières‑en‑Vimeu
France
Registration number
007-DP0185
Certification Body
Kiwa Nederland B.V.
Subtype title
HTi70 11 kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,900 kg

Certification Date
06.05.2024
Testing basis
European KEYMARK Scheme for Heat Pumps (v11)
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

HTi70 11 kW tri
Configure model
Model name
HTi70 11 kW tri
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.83 kW

8.92 kW

El input

1.79 kW

2.86 kW

COP

4.93

3.12

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

144 %

Prated

10.57 kW

10.52 kW

SCOP

4.71

3.67

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.35 kW

9.31 kW

COP Tj = -7°C

2.97

2.29

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.66 kW

5.66 kW

COP Tj = +2°C

4.48

3.49

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.68 kW

3.90 kW

COP Tj = +7°C

6.90

5.29

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.40 kW

3.29 kW

COP Tj = 12°C

8.29

6.38

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

9.35 kW

9.31 kW

COP Tj = Tbiv

2.97

2.29

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.62 kW

10.01 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.57

2.07

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

70 °C

70 °C

Poff

5 W

5 W

PTO

14 W

14 W

PSB

5 W

5 W

PCK

14 W

14 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.95 kW

0.51 kW

Annual energy consumption Qhe

4641 kWh

5926 kWh

HTi70 11 kW mono
Configure model
Model name
HTi70 11 kW mono
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.83 kW

8.92 kW

El input

1.79 kW

2.86 kW

COP

4.93

3.12

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

144 %

Prated

10.57 kW

10.52 kW

SCOP

4.71

3.67

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.35 kW

9.31 kW

COP Tj = -7°C

2.97

2.29

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.66 kW

5.66 kW

COP Tj = +2°C

4.48

3.49

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.68 kW

3.90 kW

COP Tj = +7°C

6.90

5.29

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.40 kW

3.29 kW

COP Tj = 12°C

8.29

6.38

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

9.35 kW

9.31 kW

COP Tj = Tbiv

2.97

2.29

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.62 kW

10.01 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.57

2.07

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

70 °C

70 °C

Poff

5 W

5 W

PTO

14 W

14 W

PSB

5 W

5 W

PCK

14 W

14 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.95 kW

0.51 kW

Annual energy consumption Qhe

4641 kWh

5926 kWh