Certificate holders

Subtype

HTi70 8 kW

Certificate Holder
Intuis
Rue de la République
80210 Feuquières‑en‑Vimeu
France
Registration number
007-DP0184
Certification Body
Kiwa Nederland B.V.
Subtype title
HTi70 8 kW
Driving energy
Gas
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,600 kg

Certification Date
06.05.2024
Testing basis
European KEYMARK Scheme for Heat Pumps (v11)
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

HTi70 8 kW mono
Configure model
Model name
HTi70 8 kW mono
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.72 kW

5.79 kW

El input

1.18 kW

1.79 kW

COP

4.85

3.23

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

150 %

Prated

7.50 kW

7.54 kW

SCOP

4.86

3.82

Tbiv

-5 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.52 kW

6.28 kW

COP Tj = -7°C

3.11

2.44

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.13 kW

4.12 kW

COP Tj = +2°C

4.56

3.82

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.95 kW

2.93 kW

COP Tj = +7°C

7.52

5.42

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.90 kW

1.79 kW

COP Tj = 12°C

8.89

6.46

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.06 kW

6.09 kW

COP Tj = Tbiv

3.37

2.52

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.93 kW

5.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.83

2.18

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

70 °C

70 °C

Poff

5 W

5 W

PTO

8 W

8 W

PSB

5 W

5 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.57 kW

1.84 kW

Annual energy consumption Qhe

3188 kWh

4083 kWh

HTi70 8 kW tri
Configure model
Model name
HTi70 8 kW tri
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.72 kW

5.79 kW

El input

1.18 kW

1.79 kW

COP

4.85

3.23

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

149 %

Prated

7.50 kW

7.54 kW

SCOP

4.82

3.79

Tbiv

-5 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.52 kW

6.28 kW

COP Tj = -7°C

3.11

2.44

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.13 kW

4.12 kW

COP Tj = +2°C

4.56

3.82

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.95 kW

2.93 kW

COP Tj = +7°C

7.52

5.42

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.90 kW

1.79 kW

COP Tj = 12°C

8.89

6.46

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.06 kW

6.09 kW

COP Tj = Tbiv

3.37

2.52

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.93 kW

5.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.83

2.18

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

70 °C

70 °C

Poff

5 W

5 W

PTO

14 W

14 W

PSB

5 W

5 W

PCK

14 W

14 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.57 kW

1.84 kW

Annual energy consumption Qhe

3212 kWh

4107 kWh