Certificate holders

Subtype

HTi70 6 kW

Certificate Holder
Intuis
Rue de la République
80210 Feuquières‑en‑Vimeu
France
Registration number
007-DP0183
Certification Body
Kiwa Nederland B.V.
Subtype title
HTi70 6 kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,420 kg

Certification Date
06.05.2024
Testing basis
European KEYMARK Scheme for Heat Pumps (v11)
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

HTi70 6kW mono
Configure model
Model name
HTi70 6kW mono
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.11 kW

4.24 kW

El input

0.85 kW

1.41 kW

COP

4.84

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

136 %

Prated

5.70 kW

5.70 kW

SCOP

4.72

3.48

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.56 kW

5.74 kW

COP Tj = -7°C

2.88

2.27

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.22 kW

3.21 kW

COP Tj = +2°C

4.69

3.44

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.93 kW

1.79 kW

COP Tj = +7°C

6.57

4.58

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.76 kW

1.65 kW

COP Tj = 12°C

7.92

5.78

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.70 kW

5.70 kW

COP Tj = Tbiv

2.83

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.70 kW

5.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.83

2.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

70 °C

70 °C

Poff

5 W

5 W

PTO

8 W

8 W

PSB

5 W

5 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2494 kWh

3380 kWh