2,400 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
15.03 kW
15.82 kW
El input
3.25 kW
5.28 kW
COP
4.63
2.99
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
69 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
133 %
Prated
14.57 kW
13.59 kW
SCOP
4.51
3.39
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
12.89 kW
12.02 kW
COP Tj = -7°C
3.07
2.39
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.69 kW
7.19 kW
COP Tj = +2°C
4.53
3.34
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.10 kW
7.62 kW
COP Tj = +7°C
6.21
4.56
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
9.10 kW
8.77 kW
COP Tj = 12°C
8.02
6.15
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.89 kW
12.02 kW
COP Tj = Tbiv
3.07
2.39
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.88 kW
12.38 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.84
2.17
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
55 °C
55 °C
Poff
18 W
18 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.70 kW
1.21 kW
Annual energy consumption Qhe
6678 kWh
8272 kWh