1,150 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.26 kW
11.69 kW
El input
2.50 kW
3.39 kW
COP
4.90
3.45
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
144 %
Prated
12.38 kW
11.91 kW
SCOP
4.72
3.67
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
10.95 kW
10.54 kW
COP Tj = -7°C
3.22
2.51
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.18 kW
6.61 kW
COP Tj = +2°C
4.62
3.55
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.70 kW
5.63 kW
COP Tj = +7°C
6.33
4.87
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
6.17 kW
6.62 kW
COP Tj = 12°C
7.36
6.44
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.95 kW
10.54 kW
COP Tj = Tbiv
3.22
2.51
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.33 kW
9.83 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.05
2.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
70 °C
70 °C
Poff
3 W
3 W
PTO
3 W
3 W
PSB
3 W
3 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.05 kW
2.09 kW
Annual energy consumption Qhe
5420 kWh
6711 kWh