0,800 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.87 kW
8.80 kW
El input
2.06 kW
2.58 kW
COP
4.78
3.42
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
144 %
Prated
8.32 kW
8.79 kW
SCOP
4.68
3.68
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
7.36 kW
7.78 kW
COP Tj = -7°C
3.31
2.48
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.56 kW
4.77 kW
COP Tj = +2°C
4.60
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.29 kW
4.40 kW
COP Tj = +7°C
6.05
4.93
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.72 kW
4.99 kW
COP Tj = 12°C
7.60
6.35
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.36 kW
7.78 kW
COP Tj = Tbiv
3.31
2.48
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.47 kW
7.18 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.02
2.17
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
70 °C
70 °C
Poff
8 W
8 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.85 kW
1.62 kW
Annual energy consumption Qhe
3677 kWh
4935 kWh