Certificate holders

Subtype

Bosch Compress CS3400iAWS 4 OR-S

Certificate Holder
Bosch Thermotechnik GmbH
Junkersstraße 20 - 24
73249 Wernau
Germany
Registration number
011-1W0534
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Bosch Compress CS3400iAWS 4 OR-S
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,100 kg

Certification Date
10.06.2022
Testing basis
European KEYMARK Scheme for Heat Pumps Version 12 (2023-03)
Generate PDF Export model CSV
  • Number of models 4

Models

CS3400iAWS 4 ORM-S
Configure model
Model name
CS3400iAWS 4 ORM-S
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.21 kW

3.90 kW

El input

1.12 kW

1.44 kW

COP

4.67

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

240 %

150 %

Prated

5 kW

5 kW

SCOP

6.07

3.84

Tbiv

4 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.94 kW

3.71 kW

COP Tj = +2°C

3.55

2.12

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.3 kW

3.28 kW

COP Tj = +7°C

5.52

3.39

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

2.76 kW

2.32 kW

COP Tj = 12°C

7.7

5.03

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

4.23 kW

4.02 kW

COP Tj = Tbiv

3.96

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.94 kW

3.71 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.55

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

60 °C

60 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.06 kW

1.29 kW

Annual energy consumption Qhe

1101 kWh

1741 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

148 %

108 %

Prated

5 kW

5 kW

SCOP

3.77

2.76

Tbiv

-12 °C

-11 °C

TOL

-20 °C

-17 °C

Pdh Tj = -7°C

3.15 kW

3.18 kW

COP Tj = -7°C

3.4

2.44

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

1.9 kW

1.89 kW

COP Tj = +2°C

4.61

3.55

Cdh Tj = +2 °C

0.97

0.98

Pdh Tj = +7°C

2.27 kW

1.62 kW

COP Tj = +7°C

6.12

4.27

Cdh Tj = +7 °C

0.97

0.97

Pdh Tj = 12°C

2.09 kW

1.79 kW

COP Tj = 12°C

5.97

5.18

Cdh Tj = +12 °C

0.97

0.97

Pdh Tj = Tbiv

3.69 kW

3.39 kW

COP Tj = Tbiv

3

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.24 kW

2.45 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.59

1.4

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

60 °C

60 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5 kW

5 kW

Annual energy consumption Qhe

3267 kWh

4461 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.26

2.77

COP Tj = -15°C (if TOL<-20°C)

2.43

1.59

Cdh Tj = -15 °C

0.99

0.99

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

125 %

Prated

5.00 kW

5.60 kW

SCOP

4.72

3.20

Tbiv

-7 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.36 kW

3.80 kW

COP Tj = -7°C

2.96

1.92

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.73 kW

3.30 kW

COP Tj = +2°C

4.68

3.27

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.34 kW

2.01 kW

COP Tj = +7°C

6.07

4.24

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.77 kW

2.51 kW

COP Tj = 12°C

8.02

5.80

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

4.36 kW

4.15 kW

COP Tj = Tbiv

2.96

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.93 kW

2.58 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.68

1.48

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

60 °C

60 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.07 kW

3.00 kW

Annual energy consumption Qhe

2186 kWh

3613 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

152 %

COP

3.68

Heating up time

02:30 h:min

Standby power input

33 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

277 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

100 %

COP

2.42

Heating up time

02:44 h:min

Standby power input

41 W

Reference hot water temperature

53.5 °C

Mixed water at 40°C

270 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

125 %

COP

3.02

Heating up time

02:34 h:min

Standby power input

38 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

279 l

CS3400iAWS 4 ORB-S
Configure model
Model name
CS3400iAWS 4 ORB-S
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.21 kW

3.90 kW

El input

1.12 kW

1.44 kW

COP

4.67

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

240 %

150 %

Prated

5 kW

5 kW

SCOP

6.07

3.84

Tbiv

4 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.94 kW

3.71 kW

COP Tj = +2°C

3.55

2.12

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.3 kW

3.28 kW

COP Tj = +7°C

5.52

3.39

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

2.76 kW

2.32 kW

COP Tj = 12°C

7.7

5.03

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

4.23 kW

4.02 kW

COP Tj = Tbiv

3.96

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.94 kW

3.71 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.55

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

60 °C

60 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

1.06 kW

1.29 kW

Annual energy consumption Qhe

1101 kWh

1741 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

148 %

108 %

Prated

5 kW

5 kW

SCOP

3.77

2.76

Tbiv

-12 °C

-11 °C

TOL

-20 °C

-17 °C

Pdh Tj = -7°C

3.15 kW

3.18 kW

COP Tj = -7°C

3.4

2.44

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

1.9 kW

1.89 kW

COP Tj = +2°C

4.61

3.55

Cdh Tj = +2 °C

0.97

0.98

Pdh Tj = +7°C

2.27 kW

1.62 kW

COP Tj = +7°C

6.12

4.27

Cdh Tj = +7 °C

0.97

0.97

Pdh Tj = 12°C

2.09 kW

1.79 kW

COP Tj = 12°C

5.97

5.18

Cdh Tj = +12 °C

0.97

0.97

Pdh Tj = Tbiv

3.69 kW

3.39 kW

COP Tj = Tbiv

3

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.24 kW

2.45 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.59

1.4

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

60 °C

60 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

5 kW

5 kW

Annual energy consumption Qhe

3267 kWh

4461 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.26

2.77

COP Tj = -15°C (if TOL<-20°C)

2.43

1.59

Cdh Tj = -15 °C

0.99

0.99

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

125 %

Prated

5.00 kW

5.60 kW

SCOP

4.72

3.20

Tbiv

-7 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.36 kW

3.80 kW

COP Tj = -7°C

2.96

1.92

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.73 kW

3.30 kW

COP Tj = +2°C

4.68

3.27

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.34 kW

2.01 kW

COP Tj = +7°C

6.07

4.24

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.77 kW

2.51 kW

COP Tj = 12°C

8.02

5.80

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

4.36 kW

4.15 kW

COP Tj = Tbiv

2.96

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.93 kW

2.58 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.68

1.48

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

60 °C

60 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

1.07 kW

3.00 kW

Annual energy consumption Qhe

2186 kWh

3613 kWh

CS3400iAWS 4 ORE-S
Configure model
Model name
CS3400iAWS 4 ORE-S
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.21 kW

3.9 kW

El input

1.12 kW

1.44 kW

COP

4.67

2.7

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

240 %

150 %

Prated

5 kW

5 kW

SCOP

6.07

3.84

Tbiv

4 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.94 kW

3.71 kW

COP Tj = +2°C

3.55

2.12

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.3 kW

3.28 kW

COP Tj = +7°C

5.52

3.39

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

2.76 kW

2.32 kW

COP Tj = 12°C

7.7

5.03

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

4.23 kW

4.02 kW

COP Tj = Tbiv

3.96

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.94 kW

3.71 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.55

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

60 °C

60 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.06 kW

1.29 kW

Annual energy consumption Qhe

1101 kWh

1741 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

148 %

108 %

Prated

5 kW

5 kW

SCOP

3.77

2.76

Tbiv

-12 °C

-11 °C

TOL

-20 °C

-17 °C

Pdh Tj = -7°C

3.15 kW

3.18 kW

COP Tj = -7°C

3.4

2.44

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

1.9 kW

1.89 kW

COP Tj = +2°C

4.61

3.55

Cdh Tj = +2 °C

0.97

0.98

Pdh Tj = +7°C

2.27 kW

1.62 kW

COP Tj = +7°C

6.12

4.27

Cdh Tj = +7 °C

0.97

0.97

Pdh Tj = 12°C

2.09 kW

1.79 kW

COP Tj = 12°C

5.97

5.18

Cdh Tj = +12 °C

0.97

0.97

Pdh Tj = Tbiv

3.69 kW

3.39 kW

COP Tj = Tbiv

3

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.24 kW

2.45 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.59

1.4

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

60 °C

60 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5 kW

5 kW

Annual energy consumption Qhe

3267 kWh

4461 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.26

2.77

COP Tj = -15°C (if TOL<-20°C)

2.43

1.59

Cdh Tj = -15 °C

0.99

0.99

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

125 %

Prated

5 kW

5.6 kW

SCOP

4.72

3.20

Tbiv

-7 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.36 kW

3.80 kW

COP Tj = -7°C

2.96

1.92

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.73 kW

3.30 kW

COP Tj = +2°C

4.68

3.27

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

2.34 kW

2.01 kW

COP Tj = +7°C

6.07

4.24

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

2.77 kW

2.51 kW

COP Tj = 12°C

8.02

5.80

Cdh Tj = +12 °C

0.97

0.97

Pdh Tj = Tbiv

4.36 kW

4.15 kW

COP Tj = Tbiv

2.96

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.93 kW

2.58 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.68

1.48

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

60 °C

60 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.07 kW

3.00 kW

Annual energy consumption Qhe

2186 kWh

3613 kWh

CSH3400iAWS 4 OR-S
Configure model
Model name
CSH3400iAWS 4 OR-S
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.21 kW

3.90 kW

El input

1.12 kW

1.44 kW

COP

4.67

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

240 %

150 %

Prated

5 kW

5 kW

SCOP

6.07

3.84

Tbiv

4 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.94 kW

3.71 kW

COP Tj = +2°C

3.55

2.12

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.3 kW

3.28 kW

COP Tj = +7°C

5.52

3.39

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

2.76 kW

2.32 kW

COP Tj = 12°C

7.7

5.03

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

4.23 kW

4.02 kW

COP Tj = Tbiv

3.96

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.94 kW

3.71 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.55

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

60 °C

60 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

1.06 kW

1.29 kW

Annual energy consumption Qhe

1101 kWh

1741 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

148 %

108 %

Prated

5 kW

5 kW

SCOP

3.77

2.76

Tbiv

-12 °C

-11 °C

TOL

-20 °C

-17 °C

Pdh Tj = -7°C

3.15 kW

3.18 kW

COP Tj = -7°C

3.4

2.44

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

1.9 kW

1.89 kW

COP Tj = +2°C

4.61

3.55

Cdh Tj = +2 °C

0.97

0.98

Pdh Tj = +7°C

2.27 kW

1.62 kW

COP Tj = +7°C

6.12

4.27

Cdh Tj = +7 °C

0.97

0.97

Pdh Tj = 12°C

2.09 kW

1.79 kW

COP Tj = 12°C

5.97

5.18

Cdh Tj = +12 °C

0.97

0.97

Pdh Tj = Tbiv

3.69 kW

3.39 kW

COP Tj = Tbiv

3

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.24 kW

2.45 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.59

1.4

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

60 °C

60 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

5 kW

5 kW

Annual energy consumption Qhe

3267 kWh

4461 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.26

2.77

COP Tj = -15°C (if TOL<-20°C)

2.43

1.59

Cdh Tj = -15 °C

0.99

0.99

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

125 %

Prated

5.00 kW

5.60 kW

SCOP

4.72

3.20

Tbiv

-7 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.36 kW

3.80 kW

COP Tj = -7°C

2.96

1.92

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.73 kW

3.30 kW

COP Tj = +2°C

4.68

3.27

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.34 kW

2.01 kW

COP Tj = +7°C

6.07

4.24

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.77 kW

2.51 kW

COP Tj = 12°C

8.02

5.80

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

4.36 kW

4.15 kW

COP Tj = Tbiv

2.96

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.93 kW

2.58 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.68

1.48

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

60 °C

60 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

1.07 kW

3.00 kW

Annual energy consumption Qhe

2186 kWh

3613 kWh