Certificate holders

Subtype

X-Force 16 kW

Certificate Holder
INVENTOR A.G. SINGLE MEMBER ELECTRIC APPLIANCES S.A.
2 Thoukididou str. & 24th km National Road Athens - Lamia
14565 Agios Stefanos
Greece
Registration number
041-K014-07 / 1
Certification Body
BRE
Subtype title
X-Force 16 kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,700 kg

Certification Date
19.12.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 09
Testing laboratory
TÜV SÜD Certification and Testing Co., Ltd. Guangzhou Branch, CN
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

XFM*16S*
Configure model
Model name
XFM*16S*
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.32 kW

16.31 kW

El input

3.56 kW

5.64 kW

COP

4.58

2.89

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

67 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

131 %

Prated

15.45 kW

13.03 kW

SCOP

4.55

3.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.67 kW

11.53 kW

COP Tj = -7°C

2.68

2.02

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

8.23 kW

7.34 kW

COP Tj = +2°C

4.35

3.12

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.51 kW

4.99 kW

COP Tj = +7°C

6.48

4.66

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.53 kW

6.22 kW

COP Tj = 12°C

9.43

7.41

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

13.67 kW

11.53 kW

COP Tj = Tbiv

2.68

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.13 kW

10.79 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.47

1.87

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

98 W

98 W

PTO

98 W

98 W

PSB

98 W

98 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.32 kW

2.24 kW

Annual energy consumption Qhe

7024 kWh

8023 kWh