Certificate holders

Subtype

Air to Water Heat Pump- R32- 90

Certificate Holder
Guangdong New Energy Technology Development Co., Ltd.
NO.125, Chuangyou Road
511340 Guangdong
China
Registration number
041-K054-08
Certification Body
BRE Global Limited
Subtype title
Air to Water Heat Pump- R32- 90
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,600 kg

Certification Date
13.09.2023
Testing basis
Heat Pump KEYMARK certification Scheme rules v12
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

NE-F90HCR4INEM
Configure model
Model name
NE-F90HCR4INEM
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.98 kW

9.81 kW

El input

1.92 kW

3.37 kW

COP

4.67

2.91

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

69 dB(A)

69 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

133 %

Prated

8.39 kW

8.83 kW

SCOP

4.61

3.40

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

7.43 kW

7.81 kW

COP Tj = -7°C

3.39

2.33

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.57 kW

4.81 kW

COP Tj = +2°C

4.51

3.30

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.81 kW

4.96 kW

COP Tj = +7°C

5.83

4.56

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

5.05 kW

5.44 kW

COP Tj = 12°C

8.06

6.07

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.43 kW

7.81 kW

COP Tj = Tbiv

3.39

2.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.38 kW

8.74 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

11 W

11 W

PTO

15 W

15 W

PSB

11 W

11 W

PCK

39 W

39 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.01 kW

0.09 kW

Annual energy consumption Qhe

3762 kWh

5370 kWh

NE-F90HCR4TINEM
Configure model
Model name
NE-F90HCR4TINEM
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.98 kW

9.98 kW

El input

1.93 kW

3.40 kW

COP

4.66

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

134 %

Prated

8.43 kW

8.47 kW

SCOP

4.60

3.42

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

7.46 kW

7.50 kW

COP Tj = -7°C

3.32

2.20

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.66 kW

4.70 kW

COP Tj = +2°C

4.53

3.41

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.73 kW

4.75 kW

COP Tj = +7°C

5.70

4.52

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.91 kW

5.15 kW

COP Tj = 12°C

8.33

6.38

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.46 kW

7.50 kW

COP Tj = Tbiv

3.32

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.36 kW

8.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.06

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

12 W

12 W

PTO

15 W

15 W

PSB

12 W

12 W

PCK

41 W

41 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.07 kW

0.16 kW

Annual energy consumption Qhe

3786 kWh

5124 kWh