1,200 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.00 kW
10.00 kW
El input
2.06 kW
3.33 kW
COP
4.85
3.00
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
191 %
146 %
Prated
8.60 kW
9.00 kW
SCOP
4.85
3.73
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.66 kW
8.04 kW
COP Tj = -7°C
3.08
2.26
Cdh Tj = -7 °C
0.997
0.998
Pdh Tj = +2°C
4.98 kW
5.10 kW
COP Tj = +2°C
4.68
3.66
Cdh Tj = +2 °C
0.992
0.994
Pdh Tj = +7°C
3.64 kW
3.45 kW
COP Tj = +7°C
6.81
5.08
Cdh Tj = +7 °C
0.985
0.988
Pdh Tj = 12°C
4.19 kW
4.04 kW
COP Tj = 12°C
8.92
6.91
Cdh Tj = +12 °C
0.983
0.986
Pdh Tj = Tbiv
7.66 kW
8.04 kW
COP Tj = Tbiv
3.08
2.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.58 kW
8.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.90
2.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
25 W
25 W
PSB
10 W
10 W
PCK
75 W
75 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.02 kW
0.98 kW
Annual energy consumption Qhe
3700 kWh
5020 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.00 kW
12.00 kW
El input
2.73 kW
4.07 kW
COP
4.40
2.95
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
146 %
Prated
9.00 kW
9.40 kW
SCOP
4.65
3.73
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.98 kW
8.39 kW
COP Tj = -7°C
2.90
2.37
Cdh Tj = -7 °C
0.997
0.998
Pdh Tj = +2°C
4.96 kW
5.11 kW
COP Tj = +2°C
4.37
3.49
Cdh Tj = +2 °C
0.993
0.995
Pdh Tj = +7°C
3.59 kW
3.53 kW
COP Tj = +7°C
6.80
5.34
Cdh Tj = +7 °C
0.985
0.988
Pdh Tj = 12°C
4.26 kW
4.08 kW
COP Tj = 12°C
9.28
7.08
Cdh Tj = +12 °C
0.983
0.986
Pdh Tj = Tbiv
7.98 kW
8.39 kW
COP Tj = Tbiv
2.90
2.37
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.78 kW
8.29 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.86
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
25 W
25 W
PSB
10 W
10 W
PCK
75 W
75 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.22 kW
1.11 kW
Annual energy consumption Qhe
4000 kWh
5260 kWh