Certificate holders

Subtype

DC Inverter Air to Water Heat Pump Unit-08

Certificate Holder
Ecochi GmbH
Böhmerwaldstrasse 13
85570 Markt Schwaben
Germany
Registration number
041-K067-01
Certification Body
BRE Global Limited
Subtype title
DC Inverter Air to Water Heat Pump Unit-08
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,700 kg

Certification Date
25.08.2023
Testing basis
Heat Pump KEYMARK certification Scheme rules v12
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

Indoor unit: CBHA-IG1V04- 8, Outdoor unit: CBHA-OG1V03-8
Configure model
Model name
Indoor unit: CBHA-IG1V04- 8, Outdoor unit: CBHA-OG1V03-8
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.77 kW

5.57 kW

El input

1.14 kW

1.65 kW

COP

5.07

3.37

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

54 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

143 %

Prated

6.93 kW

6.40 kW

SCOP

4.85

3.65

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

6.13 kW

5.67 kW

COP Tj = -7°C

3.09

2.29

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.83 kW

3.59 kW

COP Tj = +2°C

4.67

3.64

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.29 kW

3.02 kW

COP Tj = +7°C

6.81

4.99

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.89 kW

3.62 kW

COP Tj = 12°C

9.50

6.28

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.13 kW

5.67 kW

COP Tj = Tbiv

3.09

2.29

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.64 kW

5.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.98

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

56 °C

56 °C

Poff

20 W

20 W

PTO

23 W

23 W

PSB

20 W

20 W

PCK

30 W

30 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.29 kW

1.32 kW

Annual energy consumption Qhe

2953 kWh

3622 kWh