KITA SP 8-10-12 R290

Certificate Holder
Templari S.p.A.
Via C. Battisti, n° 169
35031 Abano Terme (PD)
Italy
Registration number
ICIM-PDC-000224
Certification Body
ICIM S.p.A.
Subtype title
KITA SP 8-10-12 R290
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,400 kg

Certification Date
02.11.2023
Testing basis
V12
Generate PDF Export model CSV
  • Number of models 6

Models

Unità esterna KITA-SP-12, 1Ph, vers. MONOBLOCCO R-290
Configure model
Model name
Unità esterna KITA-SP-12, 1Ph, vers. MONOBLOCCO R-290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.10 kW

10.93 kW

El input

2.42 kW

3.38 kW

COP

4.99

3.23

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

144 %

Prated

10.91 kW

10.32 kW

SCOP

4.83

3.68

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.61 kW

6.24 kW

COP Tj = -7°C

4.03

3.04

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.85 kW

4.66 kW

COP Tj = +2°C

6.30

4.66

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.38 kW

4.26 kW

COP Tj = +7°C

8.17

7.37

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.19 kW

4.11 kW

COP Tj = 12°C

10.35

8.80

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.90 kW

8.42 kW

COP Tj = Tbiv

2.66

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.14 kW

6.72 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.50 kW

3.50 kW

Annual energy consumption Qhe

5563 kWh

6907 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.90

8.42

COP Tj = -15°C (if TOL<-20°C)

2.66

1.94

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

159 %

Prated

12.41 kW

11.59 kW

SCOP

5.44

4.05

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.98 kW

10.25 kW

COP Tj = -7°C

3.09

2.18

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.68 kW

6.24 kW

COP Tj = +2°C

5.39

4.03

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.35 kW

4.16 kW

COP Tj = +7°C

7.51

5.62

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.19 kW

4.07 kW

COP Tj = 12°C

10.35

8.16

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.98 kW

10.25 kW

COP Tj = Tbiv

3.09

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.12 kW

9.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

1.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.20 kW

2.20 kW

Annual energy consumption Qhe

4712 kWh

5918 kWh

Unità esterna KITA-SP-12, 3Ph, vers. MONOBLOCCO R-290
Configure model
Model name
Unità esterna KITA-SP-12, 3Ph, vers. MONOBLOCCO R-290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.10 kW

10.93 kW

El input

2.42 kW

3.38 kW

COP

4.99

3.23

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

144 %

Prated

10.91 kW

10.32 kW

SCOP

4.83

3.68

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.61 kW

6.24 kW

COP Tj = -7°C

4.03

3.04

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.85 kW

4.66 kW

COP Tj = +2°C

6.30

4.66

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.38 kW

4.26 kW

COP Tj = +7°C

8.17

7.37

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.19 kW

4.11 kW

COP Tj = 12°C

10.35

8.80

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.90 kW

8.42 kW

COP Tj = Tbiv

2.66

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.14 kW

6.72 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.50 kW

3.50 kW

Annual energy consumption Qhe

5563 kWh

6907 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.90

8.42

COP Tj = -15°C (if TOL<-20°C)

2.66

1.94

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

159 %

Prated

12.41 kW

11.59 kW

SCOP

5.44

4.05

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.98 kW

10.25 kW

COP Tj = -7°C

3.09

2.18

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.68 kW

6.24 kW

COP Tj = +2°C

5.39

4.03

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.35 kW

4.16 kW

COP Tj = +7°C

7.51

5.62

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.19 kW

4.07 kW

COP Tj = 12°C

10.35

8.16

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.98 kW

10.25 kW

COP Tj = Tbiv

3.09

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.12 kW

9.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

1.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

2.20 kW

2.20 kW

Annual energy consumption Qhe

4712 kWh

5918 kWh

Unità esterna KITA-SP-8, 1Ph, vers. MONOBLOCCO R-290
Configure model
Model name
Unità esterna KITA-SP-8, 1Ph, vers. MONOBLOCCO R-290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

7.12 kW

El input

1.38 kW

1.92 kW

COP

5.78

3.70

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

138 %

Prated

5.69 kW

5.26 kW

SCOP

4.78

3.54

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.08 kW

4.81 kW

COP Tj = -7°C

4.31

3.17

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.84 kW

4.65 kW

COP Tj = +2°C

6.54

4.74

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.37 kW

4.25 kW

COP Tj = +7°C

8.20

6.50

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.19 kW

4.11 kW

COP Tj = 12°C

10.37

8.80

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

4.64 kW

4.29 kW

COP Tj = Tbiv

3.20

2.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.70 kW

3.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.46

1.74

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.00 kW

2.00 kW

Annual energy consumption Qhe

2937 kWh

3667 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.64

4.29

COP Tj = -15°C (if TOL<-20°C)

3.20

2.36

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

224 %

161 %

Prated

6.53 kW

6.02 kW

SCOP

5.61

4.09

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.78 kW

5.32 kW

COP Tj = -7°C

3.78

2.69

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.79 kW

4.52 kW

COP Tj = +2°C

5.84

4.19

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.34 kW

4.15 kW

COP Tj = +7°C

7.64

5.77

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.19 kW

4.07 kW

COP Tj = 12°C

10.37

8.16

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.78 kW

5.32 kW

COP Tj = Tbiv

3.78

2.69

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.41 kW

4.82 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.33

2.37

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

1.20 kW

1.20 kW

Annual energy consumption Qhe

2404 kWh

3039 kWh

Unità esterna KITA-SP-8, 3Ph, vers. MONOBLOCCO R-290
Configure model
Model name
Unità esterna KITA-SP-8, 3Ph, vers. MONOBLOCCO R-290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

7.12 kW

El input

1.38 kW

1.92 kW

COP

5.78

3.70

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

138 %

Prated

5.69 kW

5.26 kW

SCOP

4.78

3.54

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.08 kW

4.81 kW

COP Tj = -7°C

4.31

3.17

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.84 kW

4.65 kW

COP Tj = +2°C

6.54

4.74

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.37 kW

4.25 kW

COP Tj = +7°C

8.20

6.50

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.19 kW

4.11 kW

COP Tj = 12°C

10.37

8.80

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

4.64 kW

4.29 kW

COP Tj = Tbiv

3.20

2.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.70 kW

3.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.46

1.74

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.00 kW

2.00 kW

Annual energy consumption Qhe

2937 kWh

3667 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.64

4.29

COP Tj = -15°C (if TOL<-20°C)

3.20

2.36

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

224 %

161 %

Prated

6.53 kW

6.02 kW

SCOP

5.61

4.09

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.78 kW

5.32 kW

COP Tj = -7°C

3.78

2.69

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.79 kW

4.52 kW

COP Tj = +2°C

5.84

4.19

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.34 kW

4.15 kW

COP Tj = +7°C

7.64

5.77

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.19 kW

4.07 kW

COP Tj = 12°C

10.37

8.16

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.78 kW

5.32 kW

COP Tj = Tbiv

3.78

2.69

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.41 kW

4.82 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.33

2.37

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.20 kW

1.20 kW

Annual energy consumption Qhe

2404 kWh

3039 kWh

Unità esterna KITA-SP-10, 3Ph, vers. MONOBLOCCO R-290
Configure model
Model name
Unità esterna KITA-SP-10, 3Ph, vers. MONOBLOCCO R-290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.00 kW

9.13 kW

El input

1.84 kW

2.59 kW

COP

5.44

3.53

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

142 %

Prated

7.28 kW

6.82 kW

SCOP

4.92

3.63

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.08 kW

4.81 kW

COP Tj = -7°C

4.31

3.10

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.84 kW

4.65 kW

COP Tj = +2°C

6.54

4.74

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.37 kW

4.25 kW

COP Tj = +7°C

8.18

6.64

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.19 kW

4.11 kW

COP Tj = 12°C

10.37

8.80

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.94 kW

5.57 kW

COP Tj = Tbiv

3.04

2.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.75 kW

4.37 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.37

1.69

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

2.50 kW

2.50 kW

Annual energy consumption Qhe

3647 kWh

4628 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.94

5.57

COP Tj = -15°C (if TOL<-20°C)

3.04

2.23

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

165 %

Prated

8.34 kW

7.75 kW

SCOP

5.75

4.20

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.38 kW

6.86 kW

COP Tj = -7°C

3.59

2.56

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.79 kW

4.52 kW

COP Tj = +2°C

5.84

4.19

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.34 kW

4.15 kW

COP Tj = +7°C

7.64

5.77

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.19 kW

4.07 kW

COP Tj = 12°C

10.37

8.16

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.38 kW

6.86 kW

COP Tj = Tbiv

3.59

2.56

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.88 kW

6.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.20

2.26

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

1.50 kW

1.50 kW

Annual energy consumption Qhe

2999 kWh

3811 kWh

Unità esterna KITA-SP-10, 1Ph, vers. MONOBLOCCO R-290
Configure model
Model name
Unità esterna KITA-SP-10, 1Ph, vers. MONOBLOCCO R-290
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.00 kW

9.13 kW

El input

1.84 kW

2.59 kW

COP

5.44

3.53

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

142 %

Prated

7.28 kW

6.82 kW

SCOP

4.92

3.63

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.08 kW

4.81 kW

COP Tj = -7°C

4.31

3.10

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.84 kW

4.65 kW

COP Tj = +2°C

6.54

4.74

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.37 kW

4.25 kW

COP Tj = +7°C

8.18

6.64

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.19 kW

4.11 kW

COP Tj = 12°C

10.37

8.80

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.94 kW

5.57 kW

COP Tj = Tbiv

3.04

2.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.75 kW

4.37 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.37

1.69

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.50 kW

2.50 kW

Annual energy consumption Qhe

3647 kWh

4628 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.94

5.57

COP Tj = -15°C (if TOL<-20°C)

3.04

2.23

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

165 %

Prated

8.34 kW

7.75 kW

SCOP

5.75

4.20

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.38 kW

6.86 kW

COP Tj = -7°C

3.59

2.56

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.79 kW

4.52 kW

COP Tj = +2°C

5.84

4.19

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.34 kW

4.15 kW

COP Tj = +7°C

7.64

5.77

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.19 kW

4.07 kW

COP Tj = 12°C

10.37

8.16

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.38 kW

6.86 kW

COP Tj = Tbiv

3.59

2.56

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.88 kW

6.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.20

2.26

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

24 W

24 W

PTO

31 W

31 W

PSB

24 W

24 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

1.50 kW

Annual energy consumption Qhe

2999 kWh

3811 kWh