1,400 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.10 kW
10.93 kW
El input
2.42 kW
3.38 kW
COP
4.99
3.23
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
144 %
Prated
10.91 kW
10.32 kW
SCOP
4.83
3.68
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.61 kW
6.24 kW
COP Tj = -7°C
4.03
3.04
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.85 kW
4.66 kW
COP Tj = +2°C
6.30
4.66
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.38 kW
4.26 kW
COP Tj = +7°C
8.17
7.37
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.19 kW
4.11 kW
COP Tj = 12°C
10.35
8.80
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.90 kW
8.42 kW
COP Tj = Tbiv
2.66
1.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.14 kW
6.72 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.09
1.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
24 W
24 W
PTO
31 W
31 W
PSB
24 W
24 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.50 kW
3.50 kW
Annual energy consumption Qhe
5563 kWh
6907 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.90
8.42
COP Tj = -15°C (if TOL<-20°C)
2.66
1.94
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
215 %
159 %
Prated
12.41 kW
11.59 kW
SCOP
5.44
4.05
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.98 kW
10.25 kW
COP Tj = -7°C
3.09
2.18
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.68 kW
6.24 kW
COP Tj = +2°C
5.39
4.03
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.35 kW
4.16 kW
COP Tj = +7°C
7.51
5.62
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.19 kW
4.07 kW
COP Tj = 12°C
10.35
8.16
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.98 kW
10.25 kW
COP Tj = Tbiv
3.09
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.12 kW
9.36 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.82
1.94
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
24 W
24 W
PTO
31 W
31 W
PSB
24 W
24 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.20 kW
2.20 kW
Annual energy consumption Qhe
4712 kWh
5918 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.10 kW
10.93 kW
El input
2.42 kW
3.38 kW
COP
4.99
3.23
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
144 %
Prated
10.91 kW
10.32 kW
SCOP
4.83
3.68
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.61 kW
6.24 kW
COP Tj = -7°C
4.03
3.04
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.85 kW
4.66 kW
COP Tj = +2°C
6.30
4.66
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.38 kW
4.26 kW
COP Tj = +7°C
8.17
7.37
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.19 kW
4.11 kW
COP Tj = 12°C
10.35
8.80
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.90 kW
8.42 kW
COP Tj = Tbiv
2.66
1.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.14 kW
6.72 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.09
1.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
24 W
24 W
PTO
31 W
31 W
PSB
24 W
24 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.50 kW
3.50 kW
Annual energy consumption Qhe
5563 kWh
6907 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.90
8.42
COP Tj = -15°C (if TOL<-20°C)
2.66
1.94
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
215 %
159 %
Prated
12.41 kW
11.59 kW
SCOP
5.44
4.05
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.98 kW
10.25 kW
COP Tj = -7°C
3.09
2.18
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.68 kW
6.24 kW
COP Tj = +2°C
5.39
4.03
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.35 kW
4.16 kW
COP Tj = +7°C
7.51
5.62
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.19 kW
4.07 kW
COP Tj = 12°C
10.35
8.16
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.98 kW
10.25 kW
COP Tj = Tbiv
3.09
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.12 kW
9.36 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.82
1.94
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
24 W
24 W
PTO
31 W
31 W
PSB
24 W
24 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
2.20 kW
2.20 kW
Annual energy consumption Qhe
4712 kWh
5918 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.00 kW
7.12 kW
El input
1.38 kW
1.92 kW
COP
5.78
3.70
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
188 %
138 %
Prated
5.69 kW
5.26 kW
SCOP
4.78
3.54
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.08 kW
4.81 kW
COP Tj = -7°C
4.31
3.17
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.84 kW
4.65 kW
COP Tj = +2°C
6.54
4.74
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.37 kW
4.25 kW
COP Tj = +7°C
8.20
6.50
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.19 kW
4.11 kW
COP Tj = 12°C
10.37
8.80
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
4.64 kW
4.29 kW
COP Tj = Tbiv
3.20
2.36
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.70 kW
3.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.46
1.74
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
24 W
24 W
PTO
31 W
31 W
PSB
24 W
24 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.00 kW
2.00 kW
Annual energy consumption Qhe
2937 kWh
3667 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.64
4.29
COP Tj = -15°C (if TOL<-20°C)
3.20
2.36
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
224 %
161 %
Prated
6.53 kW
6.02 kW
SCOP
5.61
4.09
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.78 kW
5.32 kW
COP Tj = -7°C
3.78
2.69
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.79 kW
4.52 kW
COP Tj = +2°C
5.84
4.19
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.34 kW
4.15 kW
COP Tj = +7°C
7.64
5.77
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.19 kW
4.07 kW
COP Tj = 12°C
10.37
8.16
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.78 kW
5.32 kW
COP Tj = Tbiv
3.78
2.69
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.41 kW
4.82 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.33
2.37
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
24 W
24 W
PTO
31 W
31 W
PSB
24 W
24 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
1.20 kW
1.20 kW
Annual energy consumption Qhe
2404 kWh
3039 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.00 kW
7.12 kW
El input
1.38 kW
1.92 kW
COP
5.78
3.70
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
188 %
138 %
Prated
5.69 kW
5.26 kW
SCOP
4.78
3.54
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.08 kW
4.81 kW
COP Tj = -7°C
4.31
3.17
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.84 kW
4.65 kW
COP Tj = +2°C
6.54
4.74
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.37 kW
4.25 kW
COP Tj = +7°C
8.20
6.50
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.19 kW
4.11 kW
COP Tj = 12°C
10.37
8.80
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
4.64 kW
4.29 kW
COP Tj = Tbiv
3.20
2.36
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.70 kW
3.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.46
1.74
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
24 W
24 W
PTO
31 W
31 W
PSB
24 W
24 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.00 kW
2.00 kW
Annual energy consumption Qhe
2937 kWh
3667 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.64
4.29
COP Tj = -15°C (if TOL<-20°C)
3.20
2.36
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
224 %
161 %
Prated
6.53 kW
6.02 kW
SCOP
5.61
4.09
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.78 kW
5.32 kW
COP Tj = -7°C
3.78
2.69
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.79 kW
4.52 kW
COP Tj = +2°C
5.84
4.19
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.34 kW
4.15 kW
COP Tj = +7°C
7.64
5.77
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.19 kW
4.07 kW
COP Tj = 12°C
10.37
8.16
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.78 kW
5.32 kW
COP Tj = Tbiv
3.78
2.69
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.41 kW
4.82 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.33
2.37
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
24 W
24 W
PTO
31 W
31 W
PSB
24 W
24 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.20 kW
1.20 kW
Annual energy consumption Qhe
2404 kWh
3039 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.00 kW
9.13 kW
El input
1.84 kW
2.59 kW
COP
5.44
3.53
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
193 %
142 %
Prated
7.28 kW
6.82 kW
SCOP
4.92
3.63
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.08 kW
4.81 kW
COP Tj = -7°C
4.31
3.10
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.84 kW
4.65 kW
COP Tj = +2°C
6.54
4.74
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.37 kW
4.25 kW
COP Tj = +7°C
8.18
6.64
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.19 kW
4.11 kW
COP Tj = 12°C
10.37
8.80
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.94 kW
5.57 kW
COP Tj = Tbiv
3.04
2.23
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.75 kW
4.37 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.37
1.69
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
24 W
24 W
PTO
31 W
31 W
PSB
24 W
24 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
2.50 kW
2.50 kW
Annual energy consumption Qhe
3647 kWh
4628 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.94
5.57
COP Tj = -15°C (if TOL<-20°C)
3.04
2.23
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
227 %
165 %
Prated
8.34 kW
7.75 kW
SCOP
5.75
4.20
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.38 kW
6.86 kW
COP Tj = -7°C
3.59
2.56
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.79 kW
4.52 kW
COP Tj = +2°C
5.84
4.19
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.34 kW
4.15 kW
COP Tj = +7°C
7.64
5.77
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.19 kW
4.07 kW
COP Tj = 12°C
10.37
8.16
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.38 kW
6.86 kW
COP Tj = Tbiv
3.59
2.56
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.88 kW
6.34 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.20
2.26
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
24 W
24 W
PTO
31 W
31 W
PSB
24 W
24 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
1.50 kW
1.50 kW
Annual energy consumption Qhe
2999 kWh
3811 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.00 kW
9.13 kW
El input
1.84 kW
2.59 kW
COP
5.44
3.53
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
193 %
142 %
Prated
7.28 kW
6.82 kW
SCOP
4.92
3.63
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.08 kW
4.81 kW
COP Tj = -7°C
4.31
3.10
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.84 kW
4.65 kW
COP Tj = +2°C
6.54
4.74
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.37 kW
4.25 kW
COP Tj = +7°C
8.18
6.64
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.19 kW
4.11 kW
COP Tj = 12°C
10.37
8.80
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.94 kW
5.57 kW
COP Tj = Tbiv
3.04
2.23
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.75 kW
4.37 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.37
1.69
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
24 W
24 W
PTO
31 W
31 W
PSB
24 W
24 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.50 kW
2.50 kW
Annual energy consumption Qhe
3647 kWh
4628 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.94
5.57
COP Tj = -15°C (if TOL<-20°C)
3.04
2.23
Cdh Tj = -15 °C
0.900
0.900
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
50 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
227 %
165 %
Prated
8.34 kW
7.75 kW
SCOP
5.75
4.20
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.38 kW
6.86 kW
COP Tj = -7°C
3.59
2.56
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.79 kW
4.52 kW
COP Tj = +2°C
5.84
4.19
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.34 kW
4.15 kW
COP Tj = +7°C
7.64
5.77
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.19 kW
4.07 kW
COP Tj = 12°C
10.37
8.16
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.38 kW
6.86 kW
COP Tj = Tbiv
3.59
2.56
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.88 kW
6.34 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.20
2.26
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
24 W
24 W
PTO
31 W
31 W
PSB
24 W
24 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.50 kW
1.50 kW
Annual energy consumption Qhe
2999 kWh
3811 kWh